• 제목/요약/키워드: Blood Analysis

검색결과 4,870건 처리시간 0.029초

BLOOD METABOLITES LEVELS IN RELATION TO AGE AND LIVE WEIGHT IN YOUNG BUFFALO CALVES

  • Sikka, P.;Sethi, R.K.;Tomer, A.K.S.;Chopra, S.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제7권2호
    • /
    • pp.201-205
    • /
    • 1994
  • Thirty buffalo calves were randomly categorized into three groups on the basis of age, i.e. birth to 6 months; 6 to 12 months and 12-24 months. Blood samples were collected to monitor certain vital metabolites in relation to age and prediction of performance in growing buffalo calves. Amongst the various blood parameters estimated the serum glucose, cholesterol and gamma globulins have shown highly significant correlations with age and live weight-gain of the animal as well. However, the multiple regression analysis clearly indicated the influence of age and live body weight on blood metabolites in buffalo calves.

Effect of body acceleration on pulsatile flow of Casson fluid through a mild stenosed artery

  • Nagarani, P.;Sarojamma, G.
    • Korea-Australia Rheology Journal
    • /
    • 제20권4호
    • /
    • pp.189-196
    • /
    • 2008
  • The pulsatile flow of blood through a stenosed artery under the influence of external periodic body acceleration is studied. The effect of non-Newtonian nature of blood in small blood vessels has been taken into account by modeling blood as a Casson fluid. The non-linear coupled equations governing the flow are solved using perturbation analysis assuming that the Womersley frequency parameter is small which is valid for physiological situations in small blood vessels. The effect of pulsatility, stenosis, body acceleration, yield stress of the fluid and pressure gradient on the yield plane locations, velocity distribution, flow rate, shear stress and frictional resistance are investigated. It is noticed that the effect of yield stress and stenosis is to reduce flow rate and increase flow resistance. The impact of body acceleration is to enhance the flow rate and reduces resistance to flow.

내부직경 변화를 고려한 혈관의 유체-구조 상호작용 해석 (Fluid-Structure Interaction Analysis of Blood Vessel Considering Internal Diameter Variation)

  • 레사 옥타비안티;김동현;김수현;보이케 나바반;변준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.959-963
    • /
    • 2006
  • A three-dimensional elastic blood vessel model with internal diameter variation is considered to investigate internal flow characteristics and effects of structural deformation. Also, computational analyses for both the rigid model and the fully-coupled FSI model have been conducted in order to compare the shear stress, pressure distribution, and flow velocity in detail. A 70% narrowing area of asymmetric blood vessel model was especially investigated to show the versatility of fluid-structure interaction phenomenon. The results reveal that effect of fluid-structure interaction is very important to accurately investigate the flow characteristics of the blood vessel.

  • PDF

Development of an Automatic Blood Pressure Device based on Korotkoff Sounds

  • Li, Xiong;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • 제8권2호
    • /
    • pp.227-236
    • /
    • 2019
  • In this study, we develop a Korotkoff sound based automatic blood pressure measurement device including sensor, hardware, and analysis algorithm. PVDF-based sensor pattern was developed to function as a vibration sensor to detect of Korotkoff sounds, and the film's output was connected to an impedance-matching circuit. An algorithm for determining starting and ending points of the Korotkoff sounds was established, and clinical data from subjects were acquired and analyzed to find the relationship between the values obtained by the auscultatory method and from the developed device. The results from 86 out of 90 systolic measurements and 84 out of 90 diastolic measurements indicate that the developed device pass the validation criteria of the international protocol. Correlation coefficients for the values obtained by the auscultatory method and from the developed device were 0.982 and 0.980 for systolic and diastolic blood pressure, respectively. Blood pressure measurements based on Korotkoff sound signals obtained by using the developed PVDF film-based sensor module are accurate and highly correlated with measurements obtained by the traditional auscultatory method.

가정용 전자식 혈압계의 정확도에 대한 임상적 평가 (Clinical Evaluation of the Accuracy of Electronic Home Blood Pressure Measuring Devices)

  • 추진아
    • 기본간호학회지
    • /
    • 제9권1호
    • /
    • pp.101-112
    • /
    • 2002
  • Purpose: This study evaluated the accuracy of electronic devices compared with mercury sphygmomanometer. Of 132 outpatients with electronic devices. 77 who possessed oscillometric cuff devices participated in this study. Method: When the blood pressure was measured, all electronic devices were connected by means of a Y-connector to a mercury sphygmomanometer. Using the simultaneous same arm approach, each comparison was carried out three times at 2-minute intervals. Results: Compared with the mercury sphygmomanometer, the electronic devices underestimated systolic and diastolic blood pressure, respectively by $4.0{\pm}5.8mmHg$ and $2.5{\pm}67mmHg$, which satisfies the standard error range of the American Association for the Advancement of Medical Instrumentation. According to the British Hypertension Society criteria, these differences achieved C grade for both systolic and diastolic pressure. For the graphical analysis, the differences had a tendency to fulfill the permitted error limits in both diastolic and systolic blood pressure. Moreover, the purchase duration was not correlated with the accuracy of electronic devices. Conclusion: These results indicate that difference in blood pressure between electronic devices and mercury sphygmomanometer is within the standard error. Therefore, electronic blood pressure measuring devices may be useful for therapeutic self-management of hypertension.

  • PDF

우리나라 정상인의 혈중 수은량 (Mercury Contents in Normal Blood of Koreans)

  • 김용선;정규철
    • Journal of Preventive Medicine and Public Health
    • /
    • 제15권1호
    • /
    • pp.75-82
    • /
    • 1982
  • Normal range of mercury contents in blood and its relationship with urinary mercury excretion were studies with 68 healthy male adults living in Seoul city, who had no obvious evidence of .either occupational exposure to mercury or therapeutic use of mercurial agents. Mercury analysis was made by means of dithizone colorimetric method with coefficient of variation of 10.9% in .an average ranging from 5.1% to 18.0%. 1. Mercury contents in normal human blood were both normally and log-normally distributed, and better fitted to the latter. 2. Geometric mean and standard deviation of the mercury contents were $24.0(log^{-1}1.38){\pm}1.66{\mu}g/100ml(log^{-1}0.22{\mu}g/100ml)$ ranging from 7.2 to 79.7 ${\mu}g/100ml$ with 95% confidence interval. 3. Mercury contents in normal human blood differed from person to person (p<0.01), and the variability of the measurements was negligible (p>0.05). 4. Mercury in the blood was contained much higher in erythrocytes than in plasma (p<0.01), showing the geometric means of $21.0{\pm}1.25{\mu}g/100ml$ in red blood cells and $14.3{\pm}1.62{\mu}g/100ml$ in plasma, respectively. 5. Mercury contents in normal human blood had a relationship of power function with mercury excretion in urine corrected with a gram of creatinine excretion per liter of urine (p<0.10).

  • PDF

인체에서의 초생체 염색법을 이용한 제대혈내 소핵 출현 빈도 (Micronucleus Frequencies in Human Umbilical Cord Blood by the Supravital Staining Method)

  • 박혜경;이은일;류재천;김해준
    • 한국환경성돌연변이발암원학회지
    • /
    • 제22권4호
    • /
    • pp.289-295
    • /
    • 2002
  • This study was conducted to quantify of micronucleus frequencies in human umbilical cord blood by supravital staining method with acridine orange, and to find some factors that affected on micronucleus frequncies in humans. In this study, we used umbilical cord blood of new born infants that have sufficient reticulocytes compared with adult peripheral blood. The cord bloods were taken after childbirth from 60 normal infants in industrial and coastal region in Korea. The total of 3 ${mu}ell$ cord blood was applied to slide coated with acridine orange, and micronuclei were observed under fluorescent microscopy. Demographic factors and independent variables were collected from mothers by questionnaire. The frequencies of micronuclei in umbilical cord blood of new born infants were 0-5 per 2,000 reticulocytes by supravital staining method, and mean value and standard deviation were 1.75$\pm$0.97. There were no significant difference by the regions, smoking habits of father or mother. However, age of mother showed significant positive correlation with frequencies of micronuclei (p<0.05). Smoking at home by fathers also was found as a significant variable by muliple regression analysis. Therefore, further studies would be needed for genotoxicological evaluation of new born infants by microneuli test using supravital staining method.

  • PDF

Optical Detection of Red Blood Cell Aggregation in a Disposable Microfluidic Channel

  • Shin Sehyun;Jang Ju-Hee;Park Myung-Soo;Ku Yunhee;Suh Jang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권3호
    • /
    • pp.887-893
    • /
    • 2005
  • The aggregability of red blood cells (RBCs) was determined by laser backscattering light analysis in a microfluidic channel. Available techniques for RBC aggregation often adopt a rotational Couette-flow using a bob-and-cup system for disaggregating RBCs, which causes the system to be complex and expensive. A disposable microfluidic channel and vibration generating mechanism were used in the proposed new detection system for RBC aggregation. Prior to measurement, RBC aggregates in a blood sample were completely disaggregated by the application of vibration-induced shear. With the present apparatus, the aggregation indexes of RBCs can be measured easily with small quantities of a blood sample. The measurements with the present aggregometer were compared with those of LORCA and the results showed a strong correlation between them. The aggregability of the defibrinogenated blood RBCs is markedly lower than that of the normal RBCs. The noble feature of this design is the vibration-induced disaggregation mechanism, which can incorporate the disposable element that holds the blood sample.

도축우의 근출혈 유발 인자에 관한 연구 (A study on the risk factors associated with blood splash in slaughtered cattle)

  • 구경녀;변병래;심항섭;이호승;김경숙;우종태
    • 한국동물위생학회지
    • /
    • 제32권3호
    • /
    • pp.287-292
    • /
    • 2009
  • This study was conducted to analyse risk factors which can influence on blood splash in slaughtered cattle in D slaughterhouse located in Gyeonggi province in 2008. A total of 13,056 cattle were studied by several risk factors such as species, gender, body weight, meat grade, weather (temperature), transport distance, lairaging time, moving time, mixing cattle from different sources. As the result of analysis, the total mean of blood splash was 0.70% and the rate was highest (0.94%) in castrated Hanwoo. The heavier body weight, the higher blood splash rate. The farms which have had more than one experience of blood splash tend to have high grade in meat quality. As a weather factor, the rate in summer season was lower than in winter season. It increased as transport distance getting longer and decreased when the lairaging time was 2~5 hours. We could know many risk factors strongly related with the occurrence of blood splash from this study.

소주 및 맥주 음주와 혈중 수은과의 관계에 관한 연구 (Association between Blood Mercury and Drinking Soju and Beer in Korea)

  • 조준호
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.348-359
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the relationship between frequency of alcohol drinking and blood mercury concentration in Korea. Methods: This was a cross-sectional study that used data from the Korean National Health and Nutrition Examination Survey. Among them, 3,174 persons were selected for the final study. Results: The concentration of mercury in the blood increased as the frequency of drinking soju or beer increased. Similarly, in the multiple-linear regression analysis model, the frequency of soju drinking was identified as an independent variable showing a statistically significant positive linearity (p<0.001). After controlling for confounding factors, comparing those drinking 'more than twice a week' with those who almost do not drink alcohol, the adjusted ORs for exposure to high concentrations of mercury were 3.24 (95% CI, 2.10-4.99) for drinking soju and 2.07 (95% CI, 1.33-3.22) for drinking beer. The interaction effect between 'soju drinking' and 'spicy pollack and seafood stew' was not statistically significant (p=0.098) for evaluating the interaction effect between the two variables. Conclusions: The concentration of mercury in the blood increased as the frequency of drinking of soju or beer increased. The higher the frequency of alcohol drinking, the more likely is the blood mercury to be included in the high-concentration group. The results of this study can be used as important scientific evidence for the field of environmental health related to alcohol drinking and blood heavy metal exposure in Korea.