• Title/Summary/Keyword: Blood Analysis

Search Result 4,959, Processing Time 0.037 seconds

Study on Clinical Effect of Low Level Laser Therapy by Live Blood Analysis (생혈액분석을 통한 저용량 He-Ne 레이저 유침치료에 관한 임상적 연구)

  • Kim, sung-chul
    • Journal of Acupuncture Research
    • /
    • v.18 no.3
    • /
    • pp.23-34
    • /
    • 2001
  • Objective : The purpose of this study was to investigate the effect of Intravascular Laser Irradiation of Blood(ILIB) by the live blood analysis. Methods : We had analysed the changing forms of the live blood samples with Ultra Darkfield Microscope before and after Intravascular Laser Irradiation of Blood. Results and Conclusion : 1. Nomal Erythrocytes were increased significantly after ILIB by the live blood analysis. 2. Poikilocytes were decreased significantly after ILIB by the live blood analysis. 3. Target Cells were decreased significantly after ILIB by the live blood analysis. 4. Somatid was improved significantly after ILIB by the live blood analysis. 5. Erythrocyte Aggregtion was improved significantly after ILIB by the live blood analysis.

  • PDF

A study on the determination of lead in whole blood by ICP/MS (ICP/MS에 의한 전혈 중 납의 분석방법 연구)

  • Park, Kyung Su;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.240-245
    • /
    • 1997
  • An accurate analysis method for the determination of lead in whole blood by ICP/MS was developed. Whole blood samples were decomposed in microwave digestion system without any contamination and loss of lead. The 96 samples were analyzed by ICP/MS using mass$^{208}$ isotope of lead. Lead concentrations of human whole blood were ranged of $2.50{\sim}22.8{\mu}g/dL$. The accuracy of this analysis method was verified by analyzing of NIST SRM 955a series(lead in blood).

  • PDF

Micro Fluidic Component for a Blood Analysis System (혈액분석기용 유체소자의 설계기술 개발)

  • Kim, Jae Yun;Kim, Duckjong;Heo, Pil Woo;Park, Sang-Jin;Yoon, Eui Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.754-760
    • /
    • 2004
  • The miniaturization and integration are trend of modern blood analyses. Micro-Bio-Fluidics plays an important role in a micro blood analysis system. In this paper, analysis and design technology for blood analysis system is presented. Numerical simulations of a blood flow in micro separator and reservoir are conducted. As a result, we suggest on-chip micro separator, which performed plasma separation from whole blood in micro channels.

  • PDF

A study on the blood collecting device of main shaft injection molding for measuring blood glucose by CAE analysis (혈당 측정을 위한 채혈기구 메인 샤프트의 사출성형 시뮬레이션 및 시 사출에 관한 연구)

  • Baek, Seung Yub
    • Design & Manufacturing
    • /
    • v.12 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • In diabetics, daily blood glucose testing is generally required at home, and thus, performing blood collection several times a day using a blood line is essential. Blood collection in the home and in the hospital is a source of pain and is the second most common cause of infection. In blood collecting device generally consists of four major parts: inner-case, outer case, main shaft and triger, and the most import part among those for necessary functionality is the main shaft. Filling time and injection pressure, filling balance, strain-rate analysis of change based on availability of the product. The Moldflow of FEM simulation is used for the analysis of injection molding process. In this study, aims to create a technique for injection molding and manufacturing of a main shaft of a high-performance blood-collecting apparatus capable of automatically extracting a lancet to relieve pain through depth control of the lancet.

A Meta-analysis of the Association between Blood Lead and Blood Pressure (혈중 납과 혈압의 연관성에 관한 메타분석)

  • Koh, Sang-Baek;Nam, Chung-Mo;Choi, Hong-Ryul;Cha, Bong-Suk;Park, Jong-Ku;Jee, Ho-Sung;Kim, Chun-Bae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.262-268
    • /
    • 2001
  • Objectives : To integrate the results of studies which assess an association between blood lead and blood pressure. Methods : We surveyed the existing literature using a MEDLINE search with blood lead and blood pressure as key words, including reports published from January 1980 to December 2000. The criteria for quality evaluation were as follows: 1) the study subjects must have been workers exposed to lead, and 2) both blood pressure and blood lead must have been measured and presented with sufficient details so as to estimate or calculate the size of the association as a continuous variable. Among the 129 articles retrieved, 13 studies were selected for quantitative meta-analysis. Before the integration of each regression coefficient for the association between blood pressure and blood lead, a homogeneity test was conducted. Results : As the homogeneity of studies was rejected in a fixed effect model, we used the results in a random effect model. Our quantitative meta-analysis yielded weighted regression coefficients of blood lead associated with systolic blood pressure and diastolic blood pressure results of 0.0047 (95% confidence interval [CI]: -0.0061, 0.0155) and 0.0004 (95% CI: -0.0031, 0.0039), respectively. Conclusions : The published evidence suggested that there may be a weak positive association between blood lead and blood pressure, but the association is not significant.

  • PDF

Microsystems for Whole Blood Purification and Electrophysiological Analysis

  • Han, Arum;Han, Ki-Ho;Mohanty Swomitra K.;Frazier A. Bruno
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • This paper presents the development of a microsystem for whole blood purification and electrophysiological analysis of the purified cells. Magnetophoresis using continuous diamagnetic capture (DMC) was utilized for whole cell purification and electrical impedance spectroscopy (EIS) was utilized for electrophysiological analysis of the purified cells. The system was developed on silicon and plastic substrates utilizing conventional microfabrication technologies and plastic microfabrication technologies. Using the magnetophoretic microseparator, white blood cells were purified from a sample of whole blood. The experimental results of the DMC microseparator show that 89.7% of the red blood cells (RBCs) and 72.7% of the white blood cells (WBCs) could be continuously separated out from a whole blood using an external magnetic flux of 0.2 T. EIS was used as a downstream whole cell analysis tool to study the electrophysiological characteristics of purified cells. In this work, primary cultured bovine chromaffin cells and human red blood cells were characterized using EIS. Further analysis capabilities of the EIS were demonstrated by successfully obtaining unique impedance signatures for chromaffin cells based on the whole cell ion channel activity.

Clinical Study on the Effect of Exterior Vascular Laser Irradiation Therapy by Live Blood Analysis

  • Lee, Eun-Hyoung;Jeong, Jae-Ook;Min, Sung-Soon;Song, Su-Jin;Kim, Won-Ill
    • The Journal of Korean Medicine
    • /
    • v.26 no.4
    • /
    • pp.143-151
    • /
    • 2005
  • Objectives: The purpose of this study was to investigate the effect of exterior vascular laser irradiation therapy by live blood analysis. Methods: We analysed the changing forms of the live blood sample with a microscope before and after exterior vascular laser irradiation therapy of the blood. Results: Rouleau of red cells, erythrocyte aggregation of red cells, thrombocyte aggregation, uric acid crystals, red crystals, and protoplasts in blood were decreased significantly after exterior vascular laser irradiation therapy. Conclusions: This study suggests that exterior vascular laser irradiation will have positive effects in eliminating various effete matters in blood and will have efficacy in the treatment and prevention of cardiovascular system disorders and hyperlipidemia, caused by effete matters, or numbness and arthralgia caused by blood stagnancy and blood circulation disorder.

  • PDF

Correlation between Rouleau Condition of Red Blood Cell on Live Blood Analysis and Degree of Fatigue (생혈액검사상 적혈구의 연전현상과 피로도와의 상관관계)

  • Shin, Seung-Uoo;Lee, Jong-Soo
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.2 no.1
    • /
    • pp.159-168
    • /
    • 2001
  • Objectives : It is known that rouleau condition of red blood cell on live blood analysis is related to degree of fatigue. This study was planed to prove the correlation between rouleau condition of red blood cell and degree of fatigue by using the questionnaire 'Symptom Table on Fatigue Perception' that had been verified before. Methods : We analyzed the correlation between rouleau condition and degree of fatigue by calculating ratio of rouleau of red blood cell after measuring degree of fatigue by the questionnaire to the people who had not evidence of illness on health examination and did not take any medicine. Results and Conclusions : This study showed a significance of positive correlation(0.464) between physical fatigue and rouleau condition of red blood cell.

  • PDF

Evaluation of Ubiquitous High Blood-Pressure Demonstration in Sungnam (성남시 유비쿼터스 고혈압 관리에 대한 평가)

  • Lee, Won-Jae;Kim, Hye-Jung;Lee, Jae-Eun
    • Korean Journal of Health Education and Promotion
    • /
    • v.25 no.1
    • /
    • pp.13-23
    • /
    • 2008
  • Objective: The current study was to test if the developed sphygmomanometer was working well and blood pressure information could be collected and monitored systematically through the internet. We tested if the sphygmomanometer and services for blood pressure controlled high blood pressure significantly and the ubiquitous monitoring could be used further. Methods: Kyungwon University, KT Co., Gil Medical Center, LIG Nex1 Co., and Sujeong Health Center conducted an ubiquitous high blood control project in Sujeong-gu, Sungnam, Korea from Mar. 5 to May 16. We developed and applied sphygmomanometer. We distributed the devices to 27 high blood pressure patients. The blood pressures of the residents were monitored through the internet when they measured blood pressures in their homes. A nurse monitored and consulted their blood pressures in the monitoring center in Kyungwon University during the demonstration period. The consultant called them and consulted on their blood pressures in few seconds they used the sphygmomanometers. For the significance of change in blood pressure, we tested statistically with Generalized Additive Model(GAM) and Multi-level Analysis. Results: Both GAM and Multi-level Analysis showed that the blood pressures of persons with ubiquitous blood pressure management decreased significantly as time passed. Conclusions: The internet monitoring and services are considered to be promising because most of the participants were satisfied especially because somebody was caring their health. The decrease of blood pressures was significant by GAM and Multi-level Analysis. Thus, we can apply ubiquitous blood pressure management to health promotion projects.

Spectral Element modeling for the one-dimensional blood flow analysis (일차원 혈류해석을 위한 스펙트럴 요소 모델링)

  • Jang, In-Joon;Lee, U-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.152-155
    • /
    • 2008
  • The blood flow characteristics have been closely related to various cardiovascular diseases, it is very important to predict them accurate enough in an efficient way. Thus, this paper proposes a one-dimensional spectral element model for the blood flow through blood vessels. The spectral element model is formulated by using the variational method. The nonlinear terms in spectral element model are all treated as the pseudo-force and an iterative solution method is applied in the frequency domain.

  • PDF