• 제목/요약/키워드: Block wall.

검색결과 330건 처리시간 0.03초

친환경 황토벽체의 차음성능 평가에 관한 연구 (The sound insulation performance of eco-friendly loess brick wall)

  • 이태강;김율;송국곤;김선우
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구 (Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load)

  • 송정현;김기준;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

중량벽체의 차음특성에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Characteristics of Heavyweight Walls)

  • 김선우;이태강;송민정
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1078-1085
    • /
    • 1998
  • This study is carried out to investigate the characteristics of sound insulation performances for masonry walls. PC walls and ALC walls. For these purposes. 17 types of masonry walls were selected and tested in accordance with KS F 2808 at reverberation room The sound insulation performance of 8" cement block walls are graded with D-45 ∼ D-55 which are to be evaluated very favorable grade. 4" cement block walls are D-30 ∼ D-40. 1 B cement brick walls are D-40∼D-50 favorable grade. 0.5 B brick walls are D-30∼D-45. 150 mm PC wall is D-50. and ALC walls(150 mm, 200 mm) are D-30∼D-45.

  • PDF

전단스팬비 영향을 고려한 RC구속조적조 벽체의 내진성능평가 (Seismic Performance Evaluation of Confined Masonry Wall System Considering of Shear-Depth Ratio)

  • 김경태;서수연;윤승조;성기태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.1-4
    • /
    • 2005
  • To investigate the effective seismic strengthening methods for masonry walls in developing countries, a total of four confined masonry (CM) walls were constructed and tested. In order to investigate the effect of the height of application point of lateral loads and reinforcing steel bars in walls and columns for the improvement of the seismic behavior of confined concrete block masonry walls, an experimental research program is conducted. The heights of inflection point considered were 0.67 and 1.11 times the height of the wall measured from the top of foundation beam. The constant vertical axial stress applied was 0 MPa. During the test, cracking patterns, load-deflection data, and strains in reinforcement and walls in critical locations was measured. From test data, it was showed that the seismic performance of confined concrete block masonry walls was significantly affected by test variables.

  • PDF

사면보호용(斜面保護用) 범용보강(凡用補强)콘크리트블록의 개발(開發) (Development of Common Reinforced Concrete Block for Slope Protection)

  • 유능환
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.404-409
    • /
    • 2005
  • The reinforced concrete blocks for reinforced earth layer are combined with soil structures consisted of facing unit, reinforcing materials and soil. Those environmentally friendly facing units of reinforced concrete blocks are made of mine waste and tailing and that will be played a role of the effects of recycling use of wasted resources. The block are consisted of three types as curved or straight in order to control topography. The systems are also not limited to wall hight so that they are effectively used for protecting the slope of banking and cutting of earth works. The reinforced concrete blocks developed this time will be effectively applied for not only retaining wall, road, park, golf course, public office building constructions but also protecting of slope stabilization projects.

  • PDF

ALC 블록 벽체에 시공한 석재 아트월의 내충격성 평가 (Evaluation of Impact Resistance of Interior Stone Walls Constructed on the ALC Block Wall)

  • 고봉천;이덕주;김현;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2019
  • Interior stone walls are using commonly in non-bearing lightweight walls of apartments. The stones of interior wall were two types, one is a granite stone, another is a marble stone. Granite stone is attached by the epoxy adhesive and marble stone is attached by dedicated anchor and fastener. The impact resistance test was carried out interior stone walls in accordance with KS F 2613. The test methods included the impact resistance tests by each of soft impact body and hard impact body. The results of the test have proved that interior stone walls can withstand the soft impact bodies and hard impact bodies that are likely to happen in everyday life.

  • PDF

철근의 깊이, 굵기 및 간격이 GPR 신호에 미치는 영향 조사 (Examination on the influence of Depth, Size and Interval of Rebar on the Signal of Ground Penetrating Radar)

  • 김영주;이승석;안봉영;김영길
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.167-174
    • /
    • 2000
  • Ground penetrating radar(GPR) was applied for measuring depths, sizes and intervals of rebars embedded in concrete. A concrete wall was constructed for this study and a sand pool and a concrete block were used for simulation. Result of this study shows that GPR can be used for measuring rebar depths and intervals, even though it is limitary, but that measuring sizes is almost impossible. Simulation with the sand pool was helpful for research on the versatile rebar arrays though signal was not clear as real concrete wall. A concrete block with many cylindrical holes for inserting different sized rebars could not be used for simulator due to many unknown reflective waves. Antenna orientation must be perpendicular to rebars for large reflection signal.

  • PDF

수치사진영상을 이용한 보강토옹벽블록의 변위계측 실내시험 (Displacement Measuring Lab. Test of Reinforced-Soil Retaining Wall Block using 3D Digital Photogrammetry Image)

  • 한중근;정영웅;홍기권;조삼덕;김영석;배상호
    • 한국지반신소재학회논문집
    • /
    • 제5권3호
    • /
    • pp.45-52
    • /
    • 2006
  • 보강토옹벽 구조물의 안정평가 및 관리는 변위 침하계측기 등에 의해 이루어지고 있고 Total Station 등을 이용한 측량장비들도 계측에 이용되고 있다. 그러나 이러한 계측은 대부분 국부적이며, 붕괴가 예상되는 경우에만 이루어지고 있다. 이와 같은 기존의 계측시스템은 계측기의 내구성 및 관리 측면에서 많은 경제적 손실이 야기되고 있어 측정값의 신뢰성에도 많은 문제가 발생하고 있다. 따라서 본 연구에서는 기존 시스템의 단점을 극복하기 위해 개발된 수치사진영상을 이용한 계측시스템을 실내시험을 통하여 보강토옹벽의 변위계측에 적용 실시하였다. 시험결과, 옹벽의 벽면변위계측이나 변형 및 균열 등의 계측을 위한 계측시스템으로 활용이 가능할 것으로 판단되었다.

  • PDF

Impacts of Different Urban Surfaces on Summer Thermal Performance

  • Jo, Hyun-Kil;Wu, Qian
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.819-826
    • /
    • 2015
  • This study measured temperatures and albedos of urban surfaces for different colors and materials during summer, and calculated the energy budget over different urban surfaces to find out the thermal performance affecting the heat built-up. The study selected six surface colors and 13 materials common in urban landscape. Their surface temperatures (Ts) and albedos were measured at a given time interval in the daytime from June to August. Average Ts over summer season for asphalt-colored brick was $4.0^{\circ}C$ higher than that for light red-colored one and $9.7^{\circ}C$ higher than that for white-colored one. The Ts for artificial surface materials of asphalt paving, brown brick wall, and green concrete wall was $6.0^{\circ}C$ higher than that for natural and semi-natural ones of grass, grassy block, and planted concrete wall. There was the greatest difference of $16.3^{\circ}C$ at midafternoon in the Ts between asphalt paving and planted concrete wall. Average albedo over summer season of surface materials ranged from 0.08 for asphalt paving to 0.67 for white concrete wall. This difference in the albedo was associated with a maximum of $15.7^{\circ}C$ difference at midafternoon in the Ts. Increasing the albedo by 0.1 (from 0.22 to 0.32) reduced the Ts by about $1.3^{\circ}C$. Average storage heat at midday by natural and semi-natural surfaces of grass and grassy block was about 10% lower than that by artificial ones of asphalt, light-red brick, and concrete. Reflected radiation, which ultimately contributes to heating the urban atmosphere, was 3.7 times greater for light-red brick and concrete surfaces than for asphalt surface. Thus, surfaces with in-between tone and color are more effective than dark- or white-colored ones, and natural or semi-natural surfaces are much greater than artificial ones in improving the urban thermal environment. This study provides new information on correlation between Ts and air temperature, relationship between albedo and Ts, and the energy budget.

좌측성상교감신경절차단후(左側星狀交感神經節遮斷後)에 합병증(合倂症)으로 온 좌측하지온감(左側下肢溫感) (Warm Sensation of Left lower Extremity as a Complication of Left Stellate Ganglion Block)

  • 오흥근
    • The Korean Journal of Pain
    • /
    • 제1권1호
    • /
    • pp.125-128
    • /
    • 1988
  • A case of the left stellate ganglion block (SGB) with a warm serration of the left lower extremity in a 25-year-old male soldier is presented. During the Korean War, this patient received a penetrating gun shot wound from the right knee through the left abdominal wall, left upper arm and left thumb. He was evacuated to the a marine corps surgical hospital where amputation of the left thumb and an end-to-end anatomosis of the left brachial artery were performed. After surgery, left ulnar and median nerve paralysis and causalgia developed and about 9 months later an upper thoracic ganglionectomy was proposed at the Chin-Hae Navel Hospital. Before the ganglionectomy a stellate ganglion block for diagnostic and prognostic purposes was requested by the surgeon. This block was performed by the supraclavicular anterior approach using 10 ml of 2% procaine. The effect of the block including Horner's syndrome was confirmed 5 minute later in this patient. This patient returned to the ward by walking unassisted 10 minutes after the block, and complained of a warm sensation in the left lower extremity 20 minutes later as well as the left upper arm. This warm sensation in the lower extremity following ipsilateral stellate ganglion block indicates that the local anesthetics solution injected tinto the neck spread down to lumbar sympathetic ganalgion along the fascial membrane of the sympathetic chain as a consequence of the 10 minutes walk.

  • PDF