• Title/Summary/Keyword: Block Plan

Search Result 282, Processing Time 0.025 seconds

Slope Failure Along the Weathered And Mobilized Foliation Plane : Studies for Causes of the Failure and the Supporting Methodologies (풍화된 엽리면을 따라 붕괴된 대절토 사면의 붕괴요인 분석과 보강방안에 대한 연구)

  • Hwang, Sang-Gi;Kim, Young-Muk;Ji, In-Taeg;Jeon, Byoung-Choo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.775-784
    • /
    • 2009
  • Weathered foliation could act as a critical failure plane because this type of plane tend to have low roughness and long extensions. A big constructed slope at $\bigcirc\bigcirc$ road construction site was failed due to the block movement along a fault zone which is parallel to foliation. Tectonic activity reactivated a fault zone parallel to foliation, and the fault clay within the shear zone metamorphosed retrogressively to chrolite. The failed block moved when the block weigh lost the balancing with the resisting force of the retrogressively metamorphosed chrolite. Evaluating the three dimensional distribution of the foliation was critical for establishing a plan for the stabilization of the slope. For this purpose, 10 boreholes were drilled as a lattice distribution, and the BIPS analyses are performed at each boreholes. The fractures measured in the boreholes are projected into 15 cross sections and their distributions are analysed, using Fracjection software. The projection analyse show that the strike of the foliation gets dipper towards left side of the slope. This geometry indicates that there are more failure block geometry at left side of the slope. Potential failure planes are searched using the projection method, and these information are provided for further support design.

  • PDF

Bundle Block Adjustment of Omni-directional Images by a Mobile Mapping System (모바일매핑시스템으로 취득된 전방위 영상의 광속조정법)

  • Oh, Tae-Wan;Lee, Im-Pyeong
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.5
    • /
    • pp.593-603
    • /
    • 2010
  • Most spatial data acquisition systems employing a set of frame cameras may have suffered from their small fields of view and poor base-distance ratio. These limitations can be significantly reduced by employing an omni-directional camera that is capable of acquiring images in every direction. Bundle Block Adjustment (BBA) is one of the existing georeferencing methods to determine the exterior orientation parameters of two or more images. In this study, by extending the concept of the traditional BBA method, we attempt to develop a mathematical model of BBA for omni-directional images. The proposed mathematical model includes three main parts; observation equations based on the collinearity equations newly derived for omni-directional images, stochastic constraints imposed from GPS/INS data and GCPs. We also report the experimental results from the application of our proposed BBA to the real data obtained mainly in urban areas. With the different combinations of the constraints, we applied four different types of mathematical models. With the type where only GCPs are used as the constraints, the proposed BBA can provide the most accurate results, ${\pm}5cm$ of RMSE in the estimated ground point coordinates. In future, we plan to perform more sophisticated lens calibration for the omni-directional camera to improve the georeferencing accuracy of omni-directional images. These georeferenced omni-directional images can be effectively utilized for city modelling, particularly autonomous texture mapping for realistic street view.

Development of Model Plans in Three Dimensional Conformal Radiotherapy for Brain Tumors (뇌종양 환자의 3차원 입체조형 치료를 위한 뇌내 주요 부위의 모델치료계획의 개발)

  • Pyo Hongryull;Lee Sanghoon;Kim GwiEon;Keum Kichang;Chang Sekyung;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.1-16
    • /
    • 2002
  • Purpose : Three dimensional conformal radiotherapy planning is being used widely for the treatment of patients with brain tumor. However, it takes much time to develop an optimal treatment plan, therefore, it is difficult to apply this technique to all patients. To increase the efficiency of this technique, we need to develop standard radiotherapy plant for each site of the brain. Therefore we developed several 3 dimensional conformal radiotherapy plans (3D plans) for tumors at each site of brain, compared them with each other, and with 2 dimensional radiotherapy plans. Finally model plans for each site of the brain were decide. Materials and Methods : Imaginary tumors, with sizes commonly observed in the clinic, were designed for each site of the brain and drawn on CT images. The planning target volumes (PTVs) were as follows; temporal $tumor-5.7\times8.2\times7.6\;cm$, suprasellar $tumor-3\times4\times4.1\;cm$, thalamic $tumor-3.1\times5.9\times3.7\;cm$, frontoparietal $tumor-5.5\times7\times5.5\;cm$, and occipitoparietal $tumor-5\times5.5\times5\;cm$. Plans using paralled opposed 2 portals and/or 3 portals including fronto-vertex and 2 lateral fields were developed manually as the conventional 2D plans, and 3D noncoplanar conformal plans were developed using beam's eye view and the automatic block drawing tool. Total tumor dose was 54 Gy for a suprasellar tumor, 59.4 Gy and 72 Gy for the other tumors. All dose plans (including 2D plans) were calculated using 3D plan software. Developed plans were compared with each other using dose-volume histograms (DVH), normal tissue complication probabilities (NTCP) and variable dose statistic values (minimum, maximum and mean dose, D5, V83, V85 and V95). Finally a best radiotherapy plan for each site of brain was selected. Results : 1) Temporal tumor; NTCPs and DVHs of the normal tissue of all 3D plans were superior to 2D plans and this trend was more definite when total dose was escalated to 72 Gy (NTCPs of normal brain 2D $plans:27\%,\;8\%\rightarrow\;3D\;plans:1\%,\;1\%$). Various dose statistic values did not show any consistent trend. A 3D plan using 3 noncoplanar portals was selected as a model radiotherapy plan. 2) Suprasellar tumor; NTCPs of all 3D plans and 2D plans did not show significant difference because the total dose of this tumor was only 54 Gy. DVHs of normal brain and brainstem were significantly different for different plans. D5, V85, V95 and mean values showed some consistent trend that was compatible with DVH. All 3D plans were superior to 2D plans even when 3 portals (fronto-vertex and 2 lateral fields) were used for 2D plans. A 3D plan using 7 portals was worse than plans using fewer portals. A 3D plan using 5 noncoplanar portals was selected as a model plan. 3) Thalamic tumor; NTCPs of all 3D plans were lower than the 2D plans when the total dose was elevated to 72 Gy. DVHs of normal tissues showed similar results. V83, V85, V95 showed some consistent differences between plans but not between 3D plans. 3D plans using 5 noncoplanar portals were selected as a model plan. 4) Parietal (fronto- and occipito-) tumors; all NTCPs of the normal brain in 3D plans were lower than in 2D plans. DVH also showed the same results. V83, V85, V95 showed consistent trends with NTCP and DVH. 3D plans using 5 portals for frontoparietal tumor and 6 portals for occipitoparietal tumor were selected as model plans. Conclusion : NTCP and DVH showed reasonable differences between plans and were through to be useful for comparing plans. All 3D plans were superior to 2D plans. Best 3D plans were selected for tumors in each site of brain using NTCP, DVH and finally by the planner's decision.

Image Based Quality Assurance of Range Compensator for Proton Beam Therapy (양성자치료용 보상체의 영상기반 정도 관리 기반 프로그램 개발)

  • Kim, Jin-Sung;Yoon, Myong-Geun;Kim, Dong-Wook;Lim, Young-Kyung;Kwak, Jung-Won;Park, So-Ah;Shin, Dong-Ho;Shin, Jung-Wook;Lee, Se-Byeong;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • The main benefit of proton therapy over photon beam radiotherapy is the absence of exit dose, which offers the opportunity for highly conformal dose distributions to target volume while simultaneously irradiating less normal tissue. For proton beam therapy two patient specific beam modifying devices are used. The aperture is used to shape the transverse extension of the proton beam to the shape of the tumor target and a patient-specific compensator attached to the block aperture when required and used to modify the beam range as required by the treatment plan for the patient. A block of range shifting material, shaped on one face in such a way that the distal end of the proton field in the patient takes the shape of the distal end of the target volume. The mechanical quality assurance of range compensator is an essential procedure to confirm the 3 dimensional patient-specific dose distributions. We proposed a new quality assurance method for range compensator based on image processing using X-ray tube of proton therapy treatment room. The depth information, boundaries of each depth of plan compensatorfile and x-ray image of compensator were analyzed and presented over 80% matching results with proposed QA program.

  • PDF

The usefulness of Forward IMRT for Head and Neck Cancer (두경부(Head & Neck)종양에서 Forward IMRT 유용성에 관한 고찰)

  • Baek Geum Mun;Kim Dae Sup;Park Kwang Ho;Kim Chung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.41-52
    • /
    • 2003
  • I. Purpose The dose distribution in normal tissues and target lesions is very important in the treatment planning. To make the uniform dose distribution in target lesions, many methods has been used. Especially in the head and neck, the dose inhomogeneity at the skin surface should be corrected. Conventional methods have a limitation in delivering the enough doses to the planning target volume (PTV) with minimized dose to the parotid gland and spinal cord. In this study, we investigated the feasibility and the practical QA methods of the forward IMRT. II. Material and Methods The treatment plan of the forward IMRT with the partial block technique using the dynamic multi-leaf collimator (dMLC) for the patients with the nasopharyngeal cancer was verified using the dose volume histogram (DVH). The films and pinpoint chamber were used for the accurate dose verification. III. Results As a result of verifying the DVH for the 2-D treatment plan with the forward IMRT, the dose to the both parotid gland and spinal cord were reduced. So the forward IMRT could save the normal tissues and optimize the treatment. Forward IMRT can use the 3-D treatment planning system and easily assure the quality, so it is easily accessible comparing with inverse IMRT IV. Conclusion The forward IMRT could make the uniform dose in the PTV while maintaining under the tolerance dose in the normal tissues comparing with the 2-D treatment.

  • PDF

Advancement Plan on Hazardous Material Classification and Comparative Study of the Criteria in UN GHS and Safety Control of Dangerous Substances Act (UN GHS와 위험물안전관리법상의 위험물질 분류기준 비교 및 선진화 방안 연구)

  • Lee, Bong Woo;Lee, Kijun;Park, Jeongpil;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.42-50
    • /
    • 2013
  • With the rapid change of industry and the development of science and technology, more than 100,000 industrial chemicals are being used and 2,000 new materials are developed every year. Chemical products have had favorable influence on our daily life and contributed very much to the prosper of human culture. But some materials are inherently poisonous and dangerous. Korea ranks as the number 7 in world's chemical products market and the chemical sector is contributing to the economic revival through importing and exporting of the products. With the increasing domestic as well as international interests about REACH and GHS, the need for the effective and efficient chemical material management system is getting bigger and bigger. In this research, we compare the criteria in UN GHS and Safety Control of Dangerous Substances Act of Korea for the development of global standard test methods and the classification and labelling for the chemicals, and suggest an advancement plan for the introduction of the GHS in a building block approach. In addition, providing the harmonized information about chemical hazards is suggested for the elimination of international trade barriers for chemical industries.

A Study on the Planning for Access Area in the Multifamily Housing Based on the Analysis of European Examples (I) - Classification from the Typological Point of View and Normative Guide for Planning - (공동주택의 코어계획기법에 대한 연구 -유럽의 사례를 중심으로(I) - 유형학적으로 접근한 코어의 분류와 그에 따른 규범적 계획기법 -)

  • 전남일
    • Journal of the Korean housing association
    • /
    • v.14 no.2
    • /
    • pp.63-75
    • /
    • 2003
  • The planning of access area, so called "core" plays an important role of planning for multifamily housing, especially multistory housing. For all possibility of various planning and design, this area has been mostly planned and designed in uniformity. And only few attempts have so far been made in studying core, on the contrary to the unit plan or plotplan. It is keenly needed to develop various skills of planning and design in this sector. The purpose of this study is to find out the usable elements of planning and design, those are correspondent to normative targets. For this end, most possible core types are classified in to three categories: circulation types in the housing block, axis types to the entrance of housing units and number of accessed housing units. And then, sizable developments for norm of core have been effectuating in view of function, relationships both with housing unit and block. Based on this classification of types and listed norm, several European examples are analyzed and evaluated by merits and demerits of their respective core types. In addition to this analysis, some adequate planning conditions, positive vs. negative types of core, and detailed planning elements are prepared with regard to the norm of core. It is noteworthy that a variety of possible core planning cases are available by means of combination of lower categories in the classified core types. It is expected that this study will render service for some helpful planning and design guide in the practice

A Study for Control of Thermal Cracking by Heat of Hydration in Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 온도균열 제어 방안 연구)

  • Song, Suk-Jun;Yoo, Sang-Geon;Park, Ji-Woong;Kim, Eun-Kyum
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.1024-1029
    • /
    • 2009
  • According to increase of massive concrete structures, Thermal crack done by heat of hydration have been increased in a process of the execution. In case of a subway concrete box structure, thickness of structures are almost over 1 meter, and penetrating crack by external restraint takes a bad effect on the durability with a water leakage and deterioration in especially concrete wall. A try of shortening a constructing period often occurs as subway is generally constructed according to a road to decrease a traffic jam. The research proposes executing method by skipping one block as a plan of shortening a constructing period and investigate an influence on thermal cracking control. Additionally, sensitivity analysis is accomplished by changing a height of a concrete wall, and concrete placing and air temperature met with a field condition.

Research on the relationship of store unit configuration and business activation of street mall - Based on case studies of street malls in Korea - (스트릿 몰(Street Mall)의 매장 배분계획과 영업활성화의 관계에 대한 연구 - 국내 스트릿 몰의 사례를 중심으로 -)

  • Woo, Seung-Hyun;Yoon, Hea-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.202-210
    • /
    • 2009
  • This research was undertaken to prove the relationship between street mall activation and architectural plan design. The research methodology was established based on the analysis of data of two existing street malls in Korea (Western Dome & LaFesta) and theoretical studies of outdoor space design. The findings from this study are the following: First, building blocks with segments in every 50m or so are ideal for detailed communication between visitors and building contents. Second, the ratio of width of main corridor and building height should be less than 1 to provide intimate feel and keep visitors' attention concentrated in the facility. Third, store unit should have more storefronts to be exposed more to passers-by and lead more pedestrian traffic. Fourth, shape of store unit would rather be wide and shallow, instead of narrow and deep, to have more exposure to the central corridor. Fifth, the building block of the busiest(most expensive) area that is usually at the main entrance area of street mall should be flexible to fit more smaller units to maximize the profitability. Sixth, the main entrance of store should face the main pedestrian corridor to induce the influx of visitors. Lastly seventh, anchor tenant that has strong name recognition is usually located on basement or higher level to induce pedestrian traffic into the mall, key tenants that are strong and familiar brand names should be located at the corner of building block with spacing to attract visitors, provide even distribution of traffic, and support wayfinding, and local tenant should be located at small units along the central corridor or remainder spaces occurred from building core layout.

Analysis on Fluorine-18 Shielding Efficiency of Double Shield Apron using Acrylic (아크릴을 활용한 이중 차페 Apron의 F-18 차폐 효율 분석)

  • Lee, Gwon-Seong;Jeon, Yeo-Ryeong;Kim, Yong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.957-964
    • /
    • 2021
  • Fluorine-18 used in PET/CT scans is a radioactive isotope that emits positrons, and high energy annihilation gamma rays and beta rays cause exposure to radiation workers. In this study, as part of a plan to reduce the exposure dose of radiation workers working in the Department of Nuclear Medicine, the cause of the low shielding efficiency of Apron for F-18 was identified, and the effectiveness of the Apron double-shielded with acrylic was evaluated. L-Block, Apron+acrylic, Apron, Acrylic+Apron, and Acrylic five shields are used to measure the dose, and the tendencies were compared by performing a Monte Carlo simulation. As a result, it was found that the shielding rate of Apron double shielded with acrylic was about 4 to 8% higher than that of Apron single shielded. To the extent that it does not significantly affect the user's activity, double-shielded personal protective clothing with an appropriate acrylic thickness could help reduce radiation workers' exposure.