The Study of the Printability Coated Paper by the Enzyme Treatment (효소처리한 도공지의 인쇄적성에 관한 연구)

  • Kim, Chang-Keun;Yang, Eu-Seok;Kim, Byong-Hyun
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.24 no.1
    • /
    • pp.13-22
    • /
    • 2006
  • We investigated the effects of the enzyme treatment of fiber for printability of coated paper. The results could summarized as follows, 1. The samples with enzyme treatment (average 87.8%) have higher ink gloss than the blank (85.6%). Printed density showed same trends with the ink gloss. However, the ${\beta}$-Glucosidase treated sample showed the lowest printed density (2.14 %) due to the lowest thickness of the ink layer, which is influenced by coated weight and surface smoothness. 2. The samples whose base paper was Xylanase and ${\beta}$-Glucosidase treated showed higher surface strength (4.2% and 4.0%, respectively) than the blank while the samples with the Hernicellulase and ${\beta}$-Glucuronidase treatment showed lower surface strength (3.2%and 3.7%, respectively) due to the influence of air permeability. 3. Hemicellulase and ${\beta}$-Glucuronidase treated base paper, which have relatively low air permeability, showed better ink repellence (4.3 and 4.4 %, respectively) than the blank (3.8 %). 4. The blank and the Xylanase treated base paper showed high set-off, which is the last category of printability.

  • PDF

A Study on the Sensory Quality Features of Lamb Fillet Steaks with Crust Topping (Crust topping 양등심 스테이크 관능적 품질 특성 연구)

  • Seo, Min-Suk;Yoo, Seung-Seok
    • Culinary science and hospitality research
    • /
    • v.17 no.4
    • /
    • pp.295-306
    • /
    • 2011
  • This study aims to increase the flavor of a lamb filet dish. The method used was as follows. Four kinds of crusts(mustard, herb & garlic, nuts, mushrooms) were made, and they were topped over lamb filet steaks. After cooking them, the good samples (mustard(MU3), herb & garlic(HG2), nuts(NC2), mushrooms(MC3)) by different materials through a sensory test were classified The selected samples were named as 1. Blank, 2. ECl(MU3), 3. EC2(HG2), 4. EC3(NC2), and 5. EC4(MC3). And then another sensory test was conducted targeting the samples to find out which crust had the best preference value. The results of the sensory test were statistically calculated Summarizing the results, all 4 kinds of samples topped with 4 different crusts showed much higher values than Blank, the control group. That indicates that the cooking method topping a crust on a lamb filet steak dish is very effective. Among them, the HG2 sample produced by mixing 70% of bread crumbs(115.5g) and 30% of garlic chop(49.5) with the base spice consisting of parsley 8g, rosemary 3g, basil 4g and olive oil 50g was evaluated as the best crust.

  • PDF

Validation of Bulk Analysis with Simulated Swipe Samples Containing Ultra-Trace Amounts of Uranium and Plutonium Using MC-ICP-MS

  • Lim, Sang Ho;Han, Sun-Ho;Park, Jong-Ho;Park, Ranhee;Lee, Min Young;Park, Jinkyu;Lee, Chi-Gyu;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • v.6 no.3
    • /
    • pp.75-79
    • /
    • 2015
  • Suitable analytical procedures for the bulk analysis of ultra-trace amounts of uranium and plutonium have been developed using multi-collector inductively coupled mass spectrometry (MC-ICP-MS). The quantification and determination of the isotopic ratios of uranium and plutonium in three simulated swipe samples, a swipe blank, and a process blank were performed to validate the analytical performance. The analytical results for the simulated swipe samples were in good agreement with the certified values, based on the measurement quality goals for the analysis of bulk environmental samples recommended by the International Atomic Energy Agency (IAEA)

Simultaneous Determination and Occurrences of Pharmaceuticals by Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) in Environmental Aqueous Samples

  • Koo, So-Hyun;Jo, Cheon-Ho;Shin, Sun-Kyoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1192-1198
    • /
    • 2010
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in the aquatic environment. Many pharmaceuticals are not completely removed during wastewater treatment, leading to their presence in wastewater treatment effluents, rivers, lakes, and ground water. Here, we developed analytical methods for monitoring ten pharmaceuticals from surface water by LC/ESI-MS/MS. For sample clean-up and extraction, MCX (mixed cation exchange) and HLB (hydrophilic-lipophilic balance) solid-phase extraction (SPE) cartridges were used. The limits of detection (LOD) in distilled water and the blank surface water were in the range of 0.006 - 0.65 and 1.66 - 45.05 pg/mL, respectively. The limits of quantitation (LOQ) for the distilled water and the blank surface water were in the range of 0.02 - 2.17 and 5.52 - 150.15 pg/mL, respectively. The absolute recoveries for fortified water samples were between 62.1% and 125.4%. Intra-day precision and accuracy for the blank surface water were 2.9% - 24.1% (R.S.D.) and -16.3% - 16.3% (bias), respectively. In surface wastewater near rivers, chlortetracycline and acetylsalicylic acid were detected frequently in the range of 0.017 - 5.404 and 0.029 - 0.269 ng/mL, respectively. Surface water near rivers had higher levels than surface water of domestic treatment plants.

QA/QC for 222Rn analysis in groundwater (지하수 중 222Rn 분석을 위한 정도관리)

  • Jeong, Do Hwan;Kim, Moon Su;Kim, Hyun Koo;Kim, Hye Jin;Park, Sun Hwa;Han, Jin Seok;Ju, Byoung Kyu;Jeon, Sang Ho;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.86-90
    • /
    • 2013
  • $^{222}Rn$ concentrations in the groundwater samples without standard material due to the short half-life (3.82 day) were measured through the establishment of the counting efficiency of LSC (Liquid Scintillation Counter) using a standard source of $^{226}Ra$. This study for Quality Assurance/Quality Control (QA/QC) of $^{222}Rn$ analysis was performed to analyze blank samples, duplicate samples, samples of groundwater sampling before and after. In-situ blank samples collected were in the range of 0.44~6.28 pCi/L and laboratory samples were in the range of 1.66~4.95 pCi/L. Their correlation coefficient was 0.9691 and the source contamination from sampling, migration and keeping of samples were not identified. The correlation coefficient between original and duplicate samples from 65 areas was 0.9987. Because radon is an inert gas, in case of groundwater sampling, it is considered to affect the radon concentration. We analyzed samples separately by groundwater sampling before and after using distilled water, but there is no significant difference for $^{222}Rn$ concentrations in distilled waters of two types.

Bioavailability of Tripotassium Dicitrato Bismuthate by ICP-MS in Human Volunteers (ICP-MS를 사용한 구연산비스마스칼륨 (Tripotassium dicitrato bismuthate)의 생체이용률 측정)

  • Kwon, Oh-Seung;Kwon, Jee-Young;Yoon, Ae-Rin;Park, Kyung-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.2
    • /
    • pp.79-84
    • /
    • 2007
  • This study was aimed to establish analytical method of Bi to develop a guideline of the bioequivalence test of tripotassium dicitrato bismuthate (TDB). For this purpose, a simple, specific and sensitive inductively coupled plasma-mass spectrometry (ICP/MS) method were developed and validated in human plasma. Various concentrations of bismuth standard solution (0-25ng/mL) were prepared with distilled water and human blank plasma. To 10mL of the volumetric flasks, 2mL of blank plasma was added with 8ml of distilled water. Bi standard solution was added to prepare the calibration samples and injected into ICP-MS. The plasma samples obtained from volunteers given 3 tablets of bismuth (total 900mg as TDB) were analyzed as described above. As a result, the coefficients of variation were <20% in quantitation limit (0.2 ng/mL) and <15% at the rest of concentrations. The stability test by repeated freezing-thawing cycles showed that the samples were stable only for 24hr. The stability tested for samples with a short-term period of storage at room temperature and pre-treatment prior to the analysis showed very stable over 24hr. In 8 healthy Korean subjects received Denol tablets at the dose of 900mg bismuth, AUC, $C_{max},\;T_{max}$ and half-life $(t_{1/2})$ were determined to be $198.33{\pm}173.78 ng{\cdot}hr/mL,\;64.48{\pm}27.06 ng/mL,\;0.52{\pm}0.21 hr,\;and\;5.15{\pm}2.67 hr$, respectively, from the plasma bismuth concentration-time curves. In conclusion, the method was suitable for the determination of bismuth in human plasma samples and could be applied to bioequivalence test of bismuth tablet.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

Effects of Airborne Samples Collected in Yeochun on Gap Junctional Inter cellular Communication in WBF-344 Rat Liver Epithelial Cells (여천공단 일부지역의 대기오염물질이 WBF-344간 상피세포의 Gap Junctional Intercellular Communication에 미치는 영향)

  • 양재만;박재학;김윤신;이영순
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.207-214
    • /
    • 1997
  • We collected airborne complex mixtures in a industrial area of Yeochun, and examined whether these complex mixtures could affect gap junctional intercellular communication (GJIC) in a cultured WBF-344 rat liver epithelial cells (LEC). Since the reduction of GJIC plays an important role in chemical carcinogenesis, measurement of changes of GJIC is a meaningful method to screen carcinogenicity of these mixtures. High and low volume samples were dissolved in dimethyl sulfoxide (DMSO) and tested. Blank filter extractions were also examined for exclud-ing possible toxicity of filter itself, and TPA (12-O-tetradecanoylphorbol-13-acetate) and DMSO were used as positive and negative control, respectively. When the cells were exposed to samples at concentration below that required to maintain rather than 85% cell viability based on the result of neutral red uptake assay, maximal inhibition of GJIC was observed at 1hr after treatment with both high and low volume samples by scrape-loading dye transfer assay. In fluorescence recovery after photobleaching assay, recovery rates via gap junctions were 33%/min in high volume sample and 62%/min in low volume sample. In together, airborne samples collected in Yeochun inhibited GJIC in a cultured WBF-344 rat LEC. These results suggest airborne samples tested in this experiment may attribute to cause a certain type and degree of cancers in in vivo when exposured for some periods.

  • PDF

STUDY ON THE FORMABILITY OF LASER WELDED BLANKS (레이저 용접판내의 성형성에 관한 연구)

  • 강수영;류석종;김종하;이호기;이경남
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.10a
    • /
    • pp.72-84
    • /
    • 1996
  • In this study, the formability of laser welded blanks were investigated through tesile test and formability test. Several samples which had the various thickness were joined by laser welding. Mechanical properties of laser welded blank measured from the tensile test are higher than those of the base metal. Fomability is lower than that of the base metal.

  • PDF

Indoor Emission Characteristics of Liquid Household Products using Purge - and - Trap Method

  • Kwon, Ki-Dong;Jo, Wan-Kuen
    • Environmental Engineering Research
    • /
    • v.12 no.5
    • /
    • pp.203-210
    • /
    • 2007
  • Since the emissions composition from the household products have potentially been associated with health risks for building occupants, the chemical composition emitted from the products should be surveyed. The current study identified the emission composition for 42 liquid household products, using a purge-and-trap method. This evaluation was done by classifying the household products into five product classes (deodorizers, household cleaners, color removers, pesticides, and polishes). Nineteen compounds were chosen on the basis of selection criteria. The quality control program for purge-and-trap and analytical systems included tests of laboratory blank Tenax traps and blank water samples, and the determination of calibration equation, measurement precision, method detection limit (MDL), and recovery. The number of chemicals varied according to the product categories, ranging from 4 for the product category of bleaches to 12 for the product categories of air fresheners and nail color removers. For all product categories, the emission composition and concentrations varied broadly according to product. It is noteworthy that most household products emit limonene: 19 of 25 cleaning products; 5 of 6 deodorizers; 1 of 3 pesticides; 3 of 3 color removers; and 4 of 5 polishes. It was suggested that the use of household products sold in Korea could elevate the formation of secondary toxic pollutants in indoor environments, by the reaction of limonene with ozone, which entered indoor environments or might be generated by indoor sources such as electronic air cleaning devices and copying machines.