• 제목/요약/키워드: Biomedical devices

검색결과 424건 처리시간 0.027초

내시경 수술시스템의 주변장치 개발 (Development of Peripheral Devices on the Endoscopic Surgery System)

  • 이영묵;송철규;이상민;김원기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

하지 로봇재활의료기기의 안전성 및 필수성능 평가 기준 개발 (The Development of Safety and Essential Performance Criteria for Lower Extremity Robotic Assisted Gait Training System)

  • 강용완;권지연
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권3호
    • /
    • pp.190-203
    • /
    • 2023
  • The purpose of this study is to provide basic data to ensure the safety and essential performance of a Lower Extremity robotic assisted gait training system and to provide advanced technology and technical basis to the industry handling the system. Based on IEC 60601-1:2012/AMD2:2020 (Medical Electrical Equipment - General requirements for basic safety and essential performance of medical electrical equipment), IEC 62366-1:2015/AMD1:2020 (Medical devices - Part 1: Application of usability engineering to medical devices) and EN ISO 14971:2019 (Medical devices - Application of risk management to medical devices), the requirements for ensuring the safety and essential performance of the Lower Extremity robotic assisted gait training system were derived. Through the Delphi survey method and scenario analysis, which reflects the opinions and knowledge of experts in the fields of development, testing and review of technical documents, and quality assurance of medical devices, validity and reliability were conducted and obtained results with adequate content validity ratio (CVR; 0.7≤) and excellent reliability (Cronbach's α; 0.9≤). As a result, it was confirmed that the reliability and validity of the risk management process to ensure the safety and essential performance of the Lower Extremity robotic assisted gait training system are required a model can be established to provide measures to reduce risks according to the level of risk exposure caused by usage.

의복형 초소형 발광모듈을 이용한 신경근육 자극 시스템 개발 및 임상적 효과 검증 (Development of Neuromuscular Stimulus System using Wearable Ultra-miniature Lighting Modules and its Verification of Clinical Effectiveness)

  • 박세형;이종실;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.23-33
    • /
    • 2009
  • It can be used easily to reduce rehabilitation and treatment time if diagnostic and therapeutic devices are attached to cloth or body. Therefore we developed neuromuscular wearable ultra-miniature lighting modules which can improve the neuromuscular function and verified its clinical effectiveness. The system is based on the ultra-miniature lighting treatment module and there are two types of systems. One of them is designed as an attached type and the other type is combined with clothing. The wearable ultra-miniature lighting module is composed of controller (battery, MCU, bidirectional transmitter and receiver), cable, treatment medium generating device and other peripheral devices. To verify the clinical effectiveness of this device, we observed the difference of the strength of a muscle before and after 650nm and 25mW laser irradiation on the reflex point for 1 to 4 seconds. Among 48 patients having the degenerative osteoarthritis, the muscle strength before and after irradiation of laser was $21.8{\pm}7.99$ and $27.3{\pm}8.43$. According to the result, the muscle strength after treatment was significantly increased (p<0.01). To whom having difficulty in visiting to OPD(Out-Patient Department), doctors medically examine the patients and find the therapeutic point, attachment of this wearable ultra-miniature lighting module can function as self treatment (treating instrument) and treatment assist at home. If doctor can remotely control the patient and take part in treatment, the therapeutic device could contribute to prevention and care device.

경항문 내시경 수술 도구에서의 최적 활동 반경 개선을 위한 컴퓨터 시뮬레이션 연구 (Computer Simulation of the Transanal Endoscopic Microsurgery for the Improvement of Optimal Operation Range)

  • 김형태;김광기;남경원;김현호;손대경
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.482-488
    • /
    • 2009
  • Conventional devices for transanal endoscopic microsurgery that are currently used clinically for intestine or rectal cancer patients have 40 mm external diameter of rectoscope tube - induces anal damage and long-term postoperative pain for small-sized patients. In this paper, we designed rectum and rectoscope models and calculated the changing trends of operation area of the surgical tools in accordance with the step-by-step variation of design parameters of the rectoscope tube - external diameter, axial length, and distal angle. Using the results of computer simulation, we suggested an optimal set of design parameters that minimizes external diameter of the rectoscope tube and at the same time, maintains similar operation area of the surgical tools compared with commercialized devices (${\geq}\;4274.7mm^2$). The results of the simulation showed that the optimal design parameters were 35 mm external diameter, 100 mm axial length, and $45^{\circ}$ distal angle of the rectoscope tube. This result can be applied to the development of endoscopic microsurgery device that can minimize side effects to the intestine or rectal cancer patients.

KEMAR 마네킹을 이용한 단이 보청기용 FDSI 빔포밍 알고리즘의 정량적 평가 (Quantitative Evaluation of the Performance of Monaural FDSI Beamforming Algorithm using a KEMAR Mannequin)

  • 조경원;남경원;한종희;이상민;김동욱;홍성화;장동표;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권1호
    • /
    • pp.24-33
    • /
    • 2013
  • To enhance the speech perception of hearing aid users in noisy environment, most hearing aid devices adopt various beamforming algorithms such as the first-order differential microphone (DM1) and the two-stage directional microphone (DM2) algorithms that maintain sounds from the direction of the interlocutor and reduce the ambient sounds from the other directions. However, these conventional algorithms represent poor directionality ability in low frequency area. Therefore, to enhance the speech perception of hearing aid uses in low frequency range, our group had suggested a fractional delay subtraction and integration (FDSI) algorithm and estimated its theoretical performance using computer simulation in previous article. In this study, we performed a KEMAR test in non-reverberant room that compares the performance of DM1, DM2, broadband beamforming (BBF), and proposed FDSI algorithms using several objective indices such as a signal-to-noise ratio (SNR) improvement, a segmental SNR (seg-SNR) improvement, a perceptual evaluation of speech quality (PESQ), and an Itakura-Saito measure (IS). Experimental results showed that the performance of the FDSI algorithm was -3.26-7.16 dB in SNR improvement, -1.94-5.41 dB in segSNR improvement, 1.49-2.79 in PESQ, and 0.79-3.59 in IS, which demonstrated that the FDSI algorithm showed the highest improvement of SNR and segSNR, and the lowest IS. We believe that the proposed FDSI algorithm has a potential as a beamformer for digital hearing aid devices.

요 스트립검사 자동화를 위한 동시 비교 스캔 기법 예비 연구 (Automation of urine dipstick test by simultaneous scanning : A pilot study)

  • 이상봉;최성수;이인광;한정수;김완석;김원재;차은종;김경아
    • 센서학회지
    • /
    • 제19권3호
    • /
    • pp.169-175
    • /
    • 2010
  • Urinalysis is an important clinical test to diagnose urinary diseases, and dipstick method with visual inspection is widely applied in practice. Automated optical devices recently developed have disadvantages of long measurement time, big size and heavy weight, accuracy degradation with time, etc. The present study proposed a new computer scanning technique, in which the test strip and the standard chart were simultaneously scanned to remove any environmental artifacts, followed by automated differentiation with the minimum distance algorithm, leading to significant enhancement of accuracy. Experiments demonstrated an accuracy of 100 % in that all test results were identical with the human visual inspection. The present technique only uses a personal computer with scanner and shortens the test time to a great degree. The results are also stored and accumulated for later use which can be transmitted to remote locations through a network, thus could be easily integrated to any ubiquitous health care systems.

Development Brief of A Body Area Network for Ubiquitous Healthcare : An Introduction to Ubiquitous Biomedical Systems Development Center

  • Hong Joo-Hyun;Kim Nam-Jin;Cha Eun-Jong;Lee Tae-Soo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.331-335
    • /
    • 2005
  • The fusion technology of small sensor and wireless communication was followed by various application examples of the embedded system, where the social infrastructural facilities and ecological environment were wirelessly monitored. In addition, this technology represents the primary application area being extended into the healthcare field. In this study, a body area network for ubiquitous healthcare is presented. More specifically this represents a wireless biomedical signal acquisition device characterized by small size, low power consumption, pre-processing and archiving capability. Using this device, a new method for monitoring vital signs and activity is created. A PDA-based wireless sensor network enables patients to be monitored during their daily living, without any constraints. Therefore, the proposed method can be used to develop Activities of Daily Living (ADL) monitoring devices for the elderly or movement impaired people. A medical center would be able to remotely monitor the current state of elderly people and support first-aid in emergency cases. In addition, this method will reduce medical costs in society, where the average life expectancy is increasing.

Recent advances in intravital microscopy for investigation of dynamic cellular behavior in vivo

  • Choo, Yeon Woong;Jeong, Juhee;Jung, Keehoon
    • BMB Reports
    • /
    • 제53권7호
    • /
    • pp.357-366
    • /
    • 2020
  • Currently, most biological research relies on conventional experimental techniques that allow only static analyses at certain time points in vitro or ex vivo. However, if one could visualize cellular dynamics in living organisms, that would provide a unique opportunity to study key biological phenomena in vivo. Intravital microscopy (IVM) encompasses diverse optical systems for direct viewing of objects, including biological structures and individual cells in live animals. With the current development of devices and techniques, IVM addresses important questions in various fields of biological and biomedical sciences. In this mini-review, we provide a general introduction to IVM and examples of recent applications in the field of immunology, oncology, and vascular biology. We also introduce an advanced type of IVM, dubbed real-time IVM, equipped with video-rate resonant scanning. Since the realt-ime IVM can render cellular dynamics with high temporal resolution in vivo, it allows visualization and analysis of rapid biological processes.

Implantable and Flexible GaN LED for Biomedical Applications

  • 이건재
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.17.1-17.1
    • /
    • 2011
  • Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as a type of implantable LED biosensor and as a therapy tool.

  • PDF

Automated Pegboard Utilizing RFID System with Multiple Reader Antennas

  • Choi, Hyun-Ho;Ryu, Mun-Ho;Yang, Yoon-Seok;Shin, Yong-Il;Kim, Nam-Gyun
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권5호
    • /
    • pp.585-589
    • /
    • 2007
  • This study proposes an automated pegboard utilizing the RFID system with multiple reader antennas for the rehabilitation services and the occupational therapy. The system automates the scoring by detecting the plugging correctness as well as the plugging status. It also aims to increase the patient's interest and the functional intelligence. The system was prototyped and tested for the automatic capability of the scoring the session time and success rate. The proposed system will be served as the typical example for the ubiquitous rehabilitation devices.