• 제목/요약/키워드: Biomedical Monitoring

검색결과 455건 처리시간 0.025초

혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가 (Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation)

  • 김유석;박성민;심은보;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

무선 센서네트워크 기반 신호강도 맵을 이용한 재택형 위치인식 및 사용자 식별 시스템 (Position Recognition and User Identification System Using Signal Strength Map in Home Healthcare Based on Wireless Sensor Networks (WSNs))

  • 양용주;이정훈;송상하;윤영로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.494-502
    • /
    • 2007
  • Ubiquitous location based services (u-LBS) will be interested to an important services. They can easily recognize object position at anytime, anywhere. At present, many researchers are making a study of the position recognition and tracking. This paper consists of postion recognition and user identification system. The position recognition is based on location under services (LBS) using a signal strength map, a database is previously made use of empirical measured received signal strength indicator (RSSI). The user identification system automatically controls instruments which is located in home. Moreover users are able to measures body signal freely. We implemented the multi-hop routing method using the Star-Mesh networks. Also, we use the sensor devices which are satisfied with the IEEE 802.15.4 specification. The used devices are the Nano-24 modules in Octacomm Co. Ltd. A RSSI is very important factor in position recognition analysis. It makes use of the way that decides position recognition and user identification in narrow indoor space. In experiments, we can analyze properties of the RSSI, draw the parameter about position recognition. The experimental result is that RSSI value is attenuated according to increasing distances. It also derives property of the radio frequency (RF) signal. Moreover, we express the monitoring program using the Microsoft C#. Finally, the proposed methods are expected to protect a sudden death and an accident in home.

재활환자 모의보행 패턴분석을 이용한 하지 편측 장애자의 정량적 재활상태 모니터링 (Quantitative Rehabilitation Extent Monitoring for Unilateral Lower Extremity Disabled Patients using Simulated Gait Pattern Analysis)

  • 문동준;김주영;노시철;최흥호
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.227-233
    • /
    • 2014
  • In this paper, to quantitatively evaluate the degree of rehabilitation for the disabled of unilateral lower extremity, we compared the EMG pattern of normal and simulated abnormal gait. The EMG signal was measured at a rate of 1 kHz on the quadriceps and biceps femoris, the pressure sensor was attached to the sole in order to distinguish the gait cycle. Integrated EMG (IEMG) was obtained by the gait cycle, and classified four patterns that were the normal gait pattern, amplitude decrease pattern, reversed pattern, and irregular pattern. For comparison of the patterns, a curve fitting was performed using the trigonometric functions. The result of curve fitting, the method using a variable A that corresponds to the amplitude of the regression curve was able to distinguish the reverse pattern and remaining pattern. The coefficient of determination ($R^2$) representing coincidence of the pattern of the regression curve and EMG was confirmed the biggest value at the normal gait. Therefore, the degree of normal gait can be confirmed using the coefficient of determination. This results show that it is possible to quantitatively confirm the degree of unilateral lower extremity disabled rehabilitation, and it will be contributed to the study of efficient rehabilitation methods by objective analysis.

호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술 (Respiratory air flow measuring technique without sensing element on the flow stream)

  • 이인광;박준오;이수옥;신은영;김경천;김경아;차은종
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

Evaluation of NMP22 Measurement and $SurePath^{TM}$ Liquid-Based Cytology for the Diagnosis of Bladder Cancer and Comparison with Findings on Atypical Urothelial Cast in Voided Urine Sediments

  • Lee, June-Taek;Lee, Ji-Sook;Kim, In-Sik
    • 대한의생명과학회지
    • /
    • 제15권1호
    • /
    • pp.47-53
    • /
    • 2009
  • Urinary bladder cancer is diagnosed through urine cytology and cytoscopy with biopsy. An atypical urothelial cast is often found by voided urine cytology in a papillary urothelial cell carcinoma. The objective of this study is to demonstrate the significance of the evaluation of urinary nuclear matrix protein (NMP22) level and Sure Path Liquid-based cytology (SP-LBC) as compared to the examination of atypical urothelial cast in voided urine sediment for monitoring bladder cancer. From October 2007 to January 2008, we observed 3240 patients who visited the emergency laboratory of urology of Soonchunhyang University, Cheonan Hospital. Both NMP22 measurement and SP-LBC were performed in 31 patients who were positive in an atypical urothelial cast test. In particular, 26 men and 5 women were found to be atypical urothelial cast-positive persons. The average age for both men and women is 61.8. NMP22 test is positive in 23 of 31 cases (74.2%) from patients with atypical urothelial cast, while the test is negative in 8 of 31 cases (25.8%). The percentages of negativity, atypicality, suspicious malignancy, and malignancy in SP-LBC are 25.8% (8/31), 58.1% (18/31), 9.7% (3/31), and 6.5% (2/31), respectively. The relation of NMP22 positivity with the malignant degree in LBC is significant (P<0.01). Two malignant patients resulting from SP-LBC show the same results in histological examination. Overall, the study suggests the usefulness of NMP22 measurement and LBC as well as the examination of atypical urothelial cast for the diagnosis of early bladder cancer.

  • PDF

2014년 제주도 양식 넙치, Paralichthys olivaceus에 대한 VHS 및 RSIVD 모니터링 (Monitoring of VHS and RSIVD in cultured Paralichthys olivaceus of Jeju in 2014)

  • 박현경;김승민;이다원;전려진;정준범
    • 수산해양교육연구
    • /
    • 제27권3호
    • /
    • pp.879-889
    • /
    • 2015
  • The outbreak of viral diseases caused by viral haemorrhagic septicaemia virus (VHSV) and red seabream iridovirus (RSIV) have been reported in cultured olive flounder, Paralichthys olivaceus. VHSV has been a serious viral disease that infects the olive flounders in South Korea. Clinical signs of VHSV infection are skin darkening, abdominal distension and haemorrhages. Outbreaks of fish iridoviral disease was first reported from red seabream, Pagrus major farms in Japan. Recently, iridovirus infection have occurred frequently from olive flounder farms in South Korea. In this study, disease surveillance was performed to monitor the prevalence of VHSV and RSIV in olive flounder in 2014. The samples were collected from 60 different olive flounder farms in Jeju from April, May, September, November and December in 2014. RT-PCR (VHSV) or PCR (RSIV) results showed that VHSV were detected in 5 farms, but RSIV has not been detected in any farms. The migration of olive flounder was restricted for the quarantine in 5 farms of VHS outbreak. The nucleocapsid protein (N) gene and glycoprotein (G) gene sequences of the 5 Korean VHSV isolates were successfully amplified and sequenced. Phylogenetic analysis was performed using the VHSV sequences reported here together comparison with the nucleotide sequences available from the GenBank database. Phylogenetic analysis indicated that most of Korea VHSV belong to the genotype IVa and closely related to the strains from Japan and China.

공압식 박동형 심실보조장치의 공압관 내 압력 측정을 통한 박출량 추정 (Estimation of Ventricular Assist Device Outflow with the Pressures in Air Pressure Line)

  • 김영일;허균;강성민;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.119-124
    • /
    • 2014
  • A Ventricular assist device (VAD) is one of the most efficient treatments to raise the survivability of the end stage heart failure patient. However, some of LVAD patients have died for the failures and improper control of LVAD. To detect critical dangers in LVAD, the monitoring methods of LVAD outflow have been requested, because it can be affected by patient's hemodynamic states and abnormal conditions of LVAD. In the case of an external pulsatile LVAD, the air movement through the air line can be used to estimate LVAD outflow. In this study, the air movement in the air-line of the extracorporeal pulsatile LVAD was measured with a differential pressure sensor between different points. The precise estimation of air movement could be achieved by additional measurement of air pressure. In a series of in-vitro experiments, the LVAD outflow were changed according to the afterload of LVAD and the differential pressure of LVAD didn't have close correlation with the LVAD outflow that were measured with an ultrasonic flowmeter at the same time. However, new precise estimation with the data from differential pressure and one point pressure in the air-line showed higher correlations with LVAD outflow.

심장의 전기활동 측정이 가능한 체중계 설계에 관한 연구 (A Study on the Weighing scales Design for Electrical Activity Monitoring of the Heart)

  • 이강휘;강승진;김경남;민세동;최동학;이정환
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.1822-1825
    • /
    • 2015
  • 본 논문에서는 운동 전후 또는 심장 질환과 관련 있는 사용자가 체중을 측정하면서 동시에 심전도 신호를 측정하여 운동 부하에 따른 심장의 활동 상태를 모니터링 할 수 있는 장치를 고안하였다. 이를 위한 방법으로 체중계에 수정된 바이폴라 금속전극을 적용하여 표준사지 측정법을 이용하여 심장활동 신호를 측정할 수 있는 방법을 제안하였다. 체중계에서 심전도를 측정하기 위해 기존의 Ag-AgCl 전극이 아닌 금속 판 형태의 전극을 사용하였으며 이를 위해 입력 임피던스의 설계를 브릿지 형의 AC-Coupling 회로를 통해 높은 CMRR이 유지되도록 설계하였다. 또한 시시각각 변화하는 노이즈를 제거하기 위해 Savitzky-golay filter를 사용하였으며 이를 통해 Baseline wandering 이 제거된 최종 심장활동 신호를 획득하였다. R-peak 검출을 통해 기준신호와의 심박수 및 Sensitivity의 비교평가를 수행하여 이 장치의 성능을 평가한 결과 심박 검출률의 평균 Sensitivity가 97.1%로 나타났다. 동잡음 제거에 대한 알고리즘이 보다 최적화 되어 최종 출력 신호의 안정성이 향상 된다면 체중계를 통한 심박 검출의 가능성과 그 유효성이 충분할 것으로 사료된다.

Changes in facial surface temperature of laying hens under different thermal conditions

  • Kim, Na Yeon;Kim, Seong Jin;Oh, Mirae;Jang, Se Young;Moon, Sang Ho
    • Animal Bioscience
    • /
    • 제34권7호
    • /
    • pp.1235-1242
    • /
    • 2021
  • Objective: The purpose of this study was to identify through infrared thermal imaging technology the facial surface temperature (FST) of laying hens in response to the variations in their thermal environment, and to identify the regional differences in FST to determine the most stable and reliable facial regions for monitoring of thermoregulatory status in chickens. Methods: Thirty Hy-Line Brown hens (25-week-old) were sequentially exposed to three different thermal conditions; optimal (OT, 22℃±2℃), low (LT, 10℃±4℃), and high temperature (HT, 30℃±2℃). The mean values of FST in five facial regions including around the eyes, earlobes, wattles, beak and nose, and comb were recorded through infrared thermography. The maximum FST (MFST) was also identified among the five face-selective regions, and its relationship with temperature-humidity index (THI) was established to identify the range of MFST in response to the variations in their thermal environment. Results: Hens exposed to OT condition at 15:00 displayed a higher temperature at wattles and around the eyes compared to other regions (p<0.001). However, under LT condition at 05:00 to 08:00, around the eyes surface temperature showed the highest value (p<0.01). In HT, wattles temperature tended to show the highest temperature over almost time intervals. Main distribution regions of MFST were wattles (63.3%) and around the eyes (16.7%) in OT, around the eyes (50%) in LT, and wattles (62.2%) and comb (18.3%) in HT. The regression equation between MFST and THI was estimated as MFST = 35.37+0.2383×THI (R2 = 0.44; p<0.001). Conclusion: The FST and the frequency of MFST in each facial region of laying hens responded sensitively to the variations in the thermal environment. The findings of this experiment provide useful information about the effect of the thermal conditions on the specific facial regions, thus offering an opportunity to stress and welfare assessment in poultry research and industry.

펄스자기장 자극 시간에 따른 미세순환시스템 내에서 혈액의 pH변화 (Changes of Blood pH in Micro-circulation System on the Stimulated Time of Pulsed Magnetic Fields)

  • 이보람;최유경;이현숙
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.214-218
    • /
    • 2022
  • The purpose of this study was to investigate the role of the PMF in the treatment of acidosis and inflammation by monitoring the pH change for the continuity of PMF effect on the blood in the micro-circulation system that mimics the capillaries in the human body. Micro-tubes and micro-channels similar in diameter to those of arteries and arterioles were fabricated using PDMS and connected to a micro-pump for blood circulation. The continuity of PMF effect was verified in a micro-circulation system in-vitro. The pH changes for the circulating blood and for persistence time of PMF stimulus effect were confirmed using the optimized PMF conditions based on the previous studies. Also pH changes were observed by continuously stimulating PMF for a set period of time. The result was observed that the pH of the blood acidified using tBHP continued to rise from immediately after stimulation of PMF to 70 minutes of stimulation, reaching a normal pH range, and then decreasing. Our study showed that PMF has a positive effect on the control of blood pH homeostasis, so it is suggested the possibility of being used as a noninvasive treatment for acidosis treatment and anti- inflammatory treatment.