• Title/Summary/Keyword: Biomedical Engineering convergence

Search Result 394, Processing Time 0.027 seconds

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Feasibility of Using Similar Electrocardiography Measured around the Ears to Develop a Personal Authentication System (귀 주변에서 측정한 유사 심전도 기반 개인 인증 시스템 개발 가능성)

  • Choi, Ga-Young;Park, Jong-Yoon;Kim, Da-Yeong;Kim, Yeonu;Lim, Ji-Heon;Hwang, Han-Jeong
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.42-47
    • /
    • 2020
  • A personal authentication system based on biosignals has received increasing attention due to its relatively high security as compared to traditional authentication systems based on a key and password. Electrocardiography (ECG) measured from the chest or wrist is one of the widely used biosignals to develop a personal authentication system. In this study, we investigated the feasibility of using similar ECG measured behind the ears to develop a personal authentication system. To this end, similar ECGs were measured from thirty subjects using a pair of three electrodes attached behind each of the ears during resting state during which the standard Lead-I ECG was also simultaneously measured from both wrists as baseline ECG. The three ECG components, Q, R, and S, were extracted for each subject as classification features, and authentication accuracy was estimated using support vector machine (SVM) based on a 5×5-fold cross-validation. The mean authentication accuracies of Lead I-ECG and similar ECG were 90.41 ± 8.26% and 81.15 ± 7.54%, respectively. Considering a chance level of 3.33% (=1/30), the mean authentication performance of similar ECG could demonstrate the feasibility of using similar ECG measured behind the ears on the development of a personal authentication system.

Detection of Pulmonary Region in Medical Images through Improved Active Control Model

  • Kwon Yong-Jun;Won Chul-Ho;Kim Dong-Hun;Kim Pil-Un;Park Il-Yong;Park Hee-Jun;Lee Jyung-Hyun;Kim Myoung-Nam;Cho Jin-HO
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.357-363
    • /
    • 2005
  • Active contour models have been extensively used to segment, match, and track objects of interest in computer vision and image processing applications, particularly to locate object boundaries. With conventional methods an object boundary can be extracted by controlling the internal energy and external energy based on energy minimization. However, this still leaves a number of problems, such as initialization and poor convergence in concave regions. In particular, a contour is unable to enter a concave region based on the stretching and bending characteristic of the internal energy. Therefore, this study proposes a method that controls the internal energy by moving the local perpendicular bisector point of each control point on the contour, and determines the object boundary by minimizing the energy relative to the external energy. Convergence at a concave region can then be effectively implemented as regards the feature of interest using the internal energy, plus several objects can be detected using a multi-detection method based on the initial contour. The proposed method is compared with other conventional methods through objective validation and subjective consideration. As a result, it is anticipated that the proposed method can be efficiently applied to the detection of the pulmonary parenchyma region in medical images.

Observation Practice Using a Human Body Model in Medical Terminology Class (의학용어 수업에서 인체 모형을 이용한 관찰 실습)

  • Hyun-Woo Jeong;Hojun Yeom;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.2
    • /
    • pp.35-42
    • /
    • 2024
  • Biomedical engineering is a discipline that diagnoses and treats human diseases using engineering techniques based on medical and biological understanding. Proper biomedical engineering education requires education on medical terminology, human anatomy, and human physiology, but students have a preconceived notion that these basic medical subjects are subjects to be memorized. In order to eliminate these students' preconceptions, various educational methods must be developed so that students can easily access basic medical subjects. In this paper, we present a method to increase learning effectiveness by introducing observation practice of a human anatomical model to the medical terminology subject. The half-body model of the human body is a form in which various organs are assembled and can be observed by disassembling them one by one. This observation exercise consisted of questions about the organs of the head, neck, chest, and abdomen, with students working in groups to find answers. After the practice, students evaluated that this practice motivated them to learn and made it easier to understand the lecture.

Effect of Graphene on Growth of Neuroblastoma Cells

  • Park, Hye-Bin;Nam, Hyo-Geun;Oh, Hong-Gi;Kim, Jung-Hyun;Kim, Chang-Man;Song, Kwang-Soup;Jhee, Kwang-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.2
    • /
    • pp.274-277
    • /
    • 2013
  • The unique properties of graphene have earned much interest in the fields of materials science and condensedmatter physics in recent years. However, the biological applications of graphene remain largely unexplored. In this study, we investigate the cell culture conditions, which are exposed to graphene onto glass and $SiO_2$/Si using human nerve cell line, SH-SY5Y. Cell viability was 84% when cultured on glass and $SiO_2$/Si coated with graphene as compared to culturing on polystyrene surface. Fluorescence data showed that the presence of graphene did not influence cell morphology. These findings suggest that graphene may be used for biological applications.

Potential involvement of Drosophila flightless-1 in carbohydrate metabolism

  • Park, Jung-Eun;Jang, Jinho;Lee, Eun Ji;Kim, Su Jung;Yoo, Hyun Ju;Lee, Semin;Kang, Min-Ji
    • BMB Reports
    • /
    • v.51 no.9
    • /
    • pp.462-467
    • /
    • 2018
  • A previous study of ours indicated that Drosophila flightless-1 controls lipid metabolism, and that there is an accumulation of triglycerides in flightless-1 (fliI)-mutant flies, where this mutation triggers metabolic stress and an obesity phenotype. Here, with the aim of characterizing the function of FliI in metabolism, we analyzed the levels of gene expression and metabolites in fliI-mutant flies. The levels of enzymes related to glycolysis, lipogenesis, and the pentose phosphate pathway increased in fliI mutants; this result is consistent with the levels of metabolites corresponding to a metabolic pathway. Moreover, high-throughput RNA sequencing revealed that Drosophila FliI regulates the expression of genes related to biological processes such as chromosome organization, carbohydrate metabolism, and immune reactions. These results showed that Drosophila FliI regulates the expression of metabolic genes, and that dysregulation of the transcription controlled by FliI gives rise to metabolic stress and problems in the development and physiology of Drosophila.

Design and Implementation of Salivary Electrical Stimulator for xerostomia

  • Lee, Jihyeon;Yeom, Hojun
    • International journal of advanced smart convergence
    • /
    • v.6 no.4
    • /
    • pp.19-25
    • /
    • 2017
  • After 40 years of age, the saliva glands are aged and the saliva is not made enough to cause xerostomia symptoms. Side effects such as hypertension medication or diuretics that the elderly take mainly can cause xerostomia syndrome. In addition, autoimmune diseases, diabetes, anemia, depression and other common diseases that cause xerostomia symptoms. If the saliva secretion is insufficient, tooth decay and gum disease are likely to occur, and the digestive ability of the saliva is also reduced due to the lack of amylase, which is a digestive element. Once the degenerated salivary gland is restored to its normal state, it is difficult to recover. In this paper, we give electrical stimulation to the masseter which is in contact with the large pituitary gland, and stimulate the salivary gland to the utmost by using speech recognition using words corresponding to oral gymnastics. Use the STM32F407VG to implement a system to relieve xerostomia.

Transcutaneous Electrical Nerve Stimulation System for Treating Tinnitus based on the Cortex-M4 Microcontroller

  • Lee, Jaeung;Yeom, Hojun
    • International journal of advanced smart convergence
    • /
    • v.5 no.4
    • /
    • pp.10-14
    • /
    • 2016
  • Among the methods of treating tinnitus, the transcutaneous clectrical nerve stimulation (TENS) method of treating by electrical stimulation is common. However, there is a problem that surgical operation is required to stimulate the vagus nerve (VN) main trunk near most of the bronchus. Alternatively, we found that the same effect could be achieved by electrically stimulating the vagus nerve VN branch (Arnold's nerve) distributed in the outer ear. The TENS system for stimulation of vagus nerve has been developed, but it has not been able to implement to stimulate as a parameter optimized for the patient by simultaneously playing the sound of eliminating the tinnitus frequency. Therefore, in this paper, it is important to develop a safe and practical TENS device for tinnitus treatment based on a 32-bit microprocessor that simultaneously applies non-invasive and notched sounds and to develop optimal treatment methods for treating tinnitus.

Investigation on Products and Regulation of Flexible Adhesive Rubber Asphalt Type Sealant for the Development of Korea-China Joint Standard (점착유연형 고무아스팔트계 씰재의 한중 공동 품질관리 규정 개발을 위한 제품 및 기술기준 현황 조사)

  • An, Ki-Won;Kim, Dong-Bum;Choi, Su-Young;He, Xing-Yang;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.323-332
    • /
    • 2019
  • Non-curable rubberized polymer asphalt waterproof coating materials in Korea and China are manufactured without advanced quality control techniques and common standard, And they are exposed consistent water leakage problems. Import and application of Korean waterproofing products and installation methods is difficult in the present situation as the Chinese standard(JC/T 2428) is different in nature with the Korean counterpart products, And quality assurance is inevitable based on mutual standards. In order to resolve this issue, alternatives such as using standards provided by the ISO (International Organization for Standardization) are generally employed, but there is no such ISO standard as a waterproof material for non-curable rubberized polymer asphalt material. Furthermore, it is unreasonable to develop the ISO standard for rubber asphalt seals for exchange in terms of time and cost. This study proposes that the establishment of a quality standard that can be applied for both countries will be required via an joint international standard that outlines the properties of materials if applied in mutual trade exchange.

Estimation of Chest Compression Depth during Cardiopulmonary Resuscitation by using Single Frequency Analysis (단일주파수분석을 이용한 심폐소생술 흉부압박깊이 추정)

  • U, One Sang;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.211-217
    • /
    • 2017
  • During the emergency situation such as cardiac arrest, cardiopulmonary resuscitation(CPR) is the most important treatment to maintain patient's blood circulation. Since the quality of CPR can not be easily measured or evaluated by the eye, an assistive device with an accelerometer can help to assess the pressure depth of CPR. In this study, we propose a single frequency analysis method to reduce the error of the accelerometer by extracting only one frequency component from the Fourier transform process. To verify the effectiveness of the single frequency analysis, acceleration data at CPR conditions were measured at a sampling rate of 50 / sec using a wristband equipped with an acceleration sensor. Then, We compared the existing distance estimation method and the single frequency analysis method using the measured data. The amplitude value proportional to the compression depth was obtained by applying the single frequency analysis method.