• Title/Summary/Keyword: Biomedical Engineering convergence

Search Result 404, Processing Time 0.025 seconds

Snoring Detection Sleep Pillow (코골이 감지 수면베개)

  • Tran, Minh;Ahn, Dohyun;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • People sleep about one-third of their lives and their sleep time varies according to age. Adult usually sleep 8 hours a day. However, that dose not guarantee good sleep. The cause of this is due to sleep disorders like snoring and sleep apnea. In this paper, the smart pillow for detecting snoring among sleep disorders is investigated. This pillow consists of two microphones located on the left and right side of the pillow. For simple detecting, the snoring signal was converted into the pulse using a peak detection circuit. The decision of the snoring occurrence was by pulse duration. The accuracy of the snoring detection was about 97%. The research results show that the smart pillow can be use to detect the snoring during sleeping.

Analysis of Flow Visualization Results Using Fourier Transform (퓨리에 변환을 활용한 유동 가시화 비교 분석)

  • Koo, Bon-guk;Park, Jun-mo;Kang, Yong-Duck
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.199-204
    • /
    • 2019
  • In the boundary layer, vortical system has been analyzed by the statistical methods to identify the vortex interaction. However, there are the limitations in explaining vortices by the mean velocity or the standard deviation. This paper proposed a method to establish a frequency analysis by Fourier transform in order to simultaneously investigate various scale vortices. For this purpose, the flow visualization conducted to reveal a standing vortex, a hairpin vortex and a wake region around a hemisphere attached on a flat plate in a water channel. In addition, the velocity where the hairpin vortex was being generated in the wake region was measured by a hot-film anemometer. To observe changes in the vortex interaction, suction was applied through a hole in front of the hemisphere. For the evaluation of the proposed frequency analysis, the existing statistical results were compared to the frequency analysis that corresponds to the qualitative results of the flow visualization.

Sleep Management Pillow System (수면 관리 베개 시스템)

  • Ahn, Dohyun;Tran, Minh;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.212-217
    • /
    • 2019
  • In this paper, a sleep management pillow system for snoring detection and respiration measurement is investigated. The sleep management pillow system consists of four force sensing resistor(FSR) sensors, two microphones(MIC), a pillow, a measurement system. Four FSR sensors attached at the bottom part of the pillow are used for respiration measurement and snoring detection. Two microphones located at the middle left and right of the pillow are utilized for only snoring detection. The respiration and the snoring of ten young people were measured using the sleep management pillow system composed of a data acquisition board, interface circuit, and personal computer. The measurement accuracy of the respiration was about 98% and the measurement accuracy of the snoring was about 97%. The experiment results show that the sleep management pillow system can be used for snoring detection and respiration rate measurement during sleeping.

The Indoor Air Purification System Using LED and Fan for Epipremnum aureum (스킨답서스에 LED와 Fan을 이용한 실내공기정화 시스템)

  • Kim, Taehyun;Park, Junmo;Kim, Soochan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.4
    • /
    • pp.167-173
    • /
    • 2018
  • We propose an air purification system that utilizes aerial plant parts and root zone of indoor plants where light is insufficient and air circulation is bad. In order to maximize the air purification effect of the plant, the aerial plant parts illuminates mixed light combining blue and green LED and CRI(Color Rendering Index) LEDs close to natural light, respectively. And the root zone was forcibly circulated by the fan to use the soil as a filter. The indoor air purification system combined with the light source and the fan removed most polluted air in the shortest. In the case of mixed light and CRI LEDs of indoor air purification system, fine dust decreased by 14%, 14.2%, and TVOC(Total volatile organic compounds) decreased by 7.5% and 9.4%, respectively. In the experiment in which the fan was operated for 15 minutes, the TVOC decreased to 97.8%. The photosynthesis of the plant and the use of soil as a filter were able to purify polluted air in a short time. And the fan's temporary operation gave the similar effect of continuous operation.

Characteristics of cell culture on the carbon based materials (카본재질의 세포 배양 특성)

  • Nam, Hyo-geun;Oh, Hong-gi;Park, Hye-Bin;Kim, Chang-man;Jhee, Kwang-hwan;Song, Kwang-soup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1000-1002
    • /
    • 2012
  • The material with superior biocompatibility and physical-chemical stability is required to fabricate high sensitive biosensors. Many kinds of biomaterials have been evaluated to apply for bioindustry. Recently, carbon based diamond and graphene thin films have been focal pointed as bio applications and their possibility is partially evaluated. Diamond thin film has many advantages for electrochemical and biological applications, such as wide potential window (3.0~3.5V), low background current and chemical-physical stability. And graphene film has many advantages as biomaterial, chemical-physical stability and conductivity. In this work, we have cultured human nerve cell (SH-SY5Y) on the nanocrystalline diamond, mirocrystalline diamond, graphene film and cell culture dish. We use MTT assay to evaluate the characteristics of cell culture on the substrates. As a result, nerve cell is well cultured on the carbon based diamond and graphene films as similar as cell culture dish. We expect that carbon materials have been applied for bioindustry such as biosensors.

  • PDF

Disturbance Observer based Feedback Linearization Control for Electro-Hydraulic Servo Systems (전기 유압 서보 시스템의 비선형 외란 관측기 기반피드백 선형화 제어)

  • Won, Daehee;Kim, Wonhee;Chung, Chung Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.297-303
    • /
    • 2015
  • We propose a disturbance observer(DOB) based feedback linearization control to improve position tracking performance in the presence of disturbance. The proposed method consists of a disturbance observer and a feedback linearization controller. The disturbance observer is designed to estimate the load force disturbance in electro-hydraulic systems. An auxiliary state variable is proposed in order to avoid amplification of the measurement noises in the disturbance observer. Using the estimated disturbance enables the Electro-hydraulic servo systems(EHS) dynamics to be changed into feedback linearization from. In order to compensate for the disturbance and to track the desired position, the feedback linearization based controller is proposed. The proposed method has a simple structure which can easily be implemented in practice. As a result, the proposed method improves the position tracking performance in the presence of disturbance. Its performance is validated via simulations.

Noise reduction in low-dose positron emission tomography with adaptive parameter estimation in sinogram domain

  • Kyu Bom Kim;Yeonkyeong Kim;Kyuseok Kim;Su Hwan Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4127-4133
    • /
    • 2024
  • Noise reduction in low-dose positron emission tomography (PET) is a well-researched topic aimed at reducing patient radiation doses and improving diagnosis. Software-based noise reduction mainly improves the contrast between regions by reducing the variation of the acquired image. However, it should be performed under appropriate parameters to reduce discrimination. We propose a method that derives optimal noise-reduction parameters using the multi-scale structural similarity index measure and visual information fidelity, which are metrics for image quality assessment. Simulation and experimental studies demonstrated the viability of the proposed algorithm. The contrast-to-noise ratio value of the denoised reconstruction slice, which was used as the optimal parameter, increased approximately three times compared to that of the low-dose slice while preserving the resolution. The results indicate that the proposed method successfully predicted the parameters according to the noise-reduction algorithm and PET system conditions in the sinogram domain. The proposed algorithm should help prevent misdiagnosis and provide standardized medical images for clinical application by performing appropriate noise reduction.

Accuracy and radiation exposure from image-guidance in Tomotherapy Hi-Art System (토모테라피 Hi-Art System의 영상유도 정확성 평가와 환자 피폭에 관한 연구)

  • Jang, Jae-Uk;Lim, Hyun-Soo;Han, Man-Seok;Kim, Yong-Kyun;Jeon, Min-Cheol
    • Journal of Digital Convergence
    • /
    • v.11 no.10
    • /
    • pp.577-584
    • /
    • 2013
  • IGRT(Image Guided Radiation Therapy) in radiation therapy is a very useful technique in order to increase setup of patient and position reproducibility. Tomotherapy can increase accuracy of setup to take IGRT by MVCT, but it be for verified accuracy of Image guided, and MVCT occurs the exposure of patient. Through this study, IGRT accuracy of Tomotherapy is very accurate within 1.0mm. When MVCT using Tomotherapy phantom for QA, QC be taken, exposure dose is Fine(2mm Slice thickness) 3cGy, Normal(4mm Slice thickness) 1.5cGy, Corse(6mmSlice thickness) 1.0cGy. Measurement value of spatial resolution using AAPM CT performance phantom did't cause a big difference. As a result, ability of IGRT in Tomotherapy is very accurate. While obtaining image for IGRT, we should minimize expose range because patient's be exposed to radiation. We should make an effort to do accurate radiation therapy to minimize exposure of patient by selecting the appropriate thickness of MVCT depending on patient's body and treat area.

Green synthesis of fluorescent carbon dots from carrot juice for in vitro cellular imaging

  • Liu, Yang;Liu, Yanan;Park, Mira;Park, Soo-Jin;Zhang, Yifan;Akanda, Md Rashedunnabi;Park, Byung-Yong;Kim, Hak Yong
    • Carbon letters
    • /
    • v.21
    • /
    • pp.61-67
    • /
    • 2017
  • We report the use of carrot, a new and inexpensive biomaterial source, for preparing high quality carbon dots (CDs) instead of semi-conductive quantum dots for bioimaging application. The as-derived CDs possessing down and up-conversion photoluminescence features were obtained from carrot juice by commonly used hydrothermal treatment. The corresponding physiochemical and optical properties were investigated by electron microscopy, fluorescent spectrometry, and other spectroscopic methods. The surfaces of obtained CDs were highly covered with hydroxyl groups and nitrogen groups without further modification. The quantum yield of as-obtained CDs was as high as 5.16%. The cell viability of HaCaT cells against a purified CD aqueous solution was higher than 85% even at higher concentration ($700{\mu}g\;mL^{-1}$) after 24 h incubation. Finally, CD cultured cells exhibited distinguished blue, green, and red colors, respectively, during in vitro imaging when excited by three wavelength lasers under a confocal microscope. Offering excellent optical properties, biocompatibility, low cytotoxicity, and good cellular imaging capability, the carrot juice derived CDs are a promising candidate for biomedical applications.

The Convergence Effects on the Grip Strength in Change of Shoulder Angle on Horizontal Plane (수평면에서 어깨각도변화에 따른 여대생의 악력에 대한 융복합적 연구)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Cho, Mi-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.81-86
    • /
    • 2020
  • The Purpose of this study is analysis characteristic of grasping power with each different shoulder horizontal angle. Twenty female university students with no shoulder dysfuction participated subject in three different positions of shoulder horizontal flexion with standing posture, shoulder 0° flexion, elbow 90° flexion, forearm 90° pronation, different positions is followed : shoulder 0° horizontal adduction shoulder 40° horizontal adduction, shoulder 40° horizontal abduction. The One-way repeated ANOVA test was used to determine the different in grip strength on three shoulder horizontal positions. On the average, in the hand grip strength, the horizontal neutral position is higher than horizontal adduction position with significant value. In particular, shoulder horizontal aduction was measured lowest grip strength between three positions.