• 제목/요약/키워드: Biological signal

검색결과 1,271건 처리시간 0.026초

WT평면에서의 디지탈 청각 보조 신호 처리 시스템의 설계 (A Study on the Design of a Digital Hearing Aids Signal Processing System in the Wavelet Transform Domain)

  • 이현철;석광원
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.347-354
    • /
    • 1996
  • This paper presents digital hearing aids signal processing system in WT(wavelet transform) domain. For implementation of hearing aids in WT domain, the gain in frequency domain is approximated in WT domain. We also present the gain selection algorithm to deal with the change of input signal power. Most transform methods produce blocking effect, and this effect degrades the convergence rate of feedback canceller. As a solution, we proposed wavelet transform bascd feedback canceller. To evaluate the performance, we compared it with LOT (lapped orthogonal transform) method in the frequency domain. This system has not shown the blocking effect, and improves convergence rate as compared with the LOT based feedback canceller.

  • PDF

MR DANTE 고속 영상에서 SNR의 개선에 관한 연구 (Improvement of SNR in DANTE Fast MR Imaging)

  • 정성택
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.87-96
    • /
    • 1997
  • A pixel profile in the conventional DANTE sequence is so poor that the excited area by DANTE sequence is a small portion of a pixel. This causes poor signal to noise ratio in DANTE image. In this paper, a frequency modulated(FM) DANTE imaging sequence is proposed to improve pixel profile in DANTE image. A DANTE pulse train is shaped by an FM function so that all the spins within a pixel are excited, thereby improving the signal to noise ratio. It also shows that the pixel profiles are dependent on the sweep in FM signal. Computer simulations and experimental result obtained using a 7.0 T NMR imaging system are presented.

  • PDF

의공학적 기법에 의한 간암의 검진과 치료경과의 정량 : 칼만 필터링 기법에 의한 초음파 영상 처리 (Bioengineering Approaches to Quantitation of Diagnosis and Treatment Monitoring for Patients with Liver Cancer: Ultrasonic Image Processing by Kalman Filtering)

  • 우광방;남상일
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권1호
    • /
    • pp.5-12
    • /
    • 1985
  • In this paper Kalman filtering technique is applied to ultrasound signal to improve resolution capability, Ivhlch is in use of diagnostic imaging systems. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to tlme varing system. Because soft-tissues, such as liver, act as distributed acoustic low-pass filters which continually change the propagating pulse. tIne can put to practical use above advantage to find a suitable signal generallng model. In state-space description of the system, the 6th order system produces tl)e 1)esc spectral approximation to the source pulse As a result of spectrum analysis, 6th order estimator for two closely spaced ((p.5 mm) reflectors enhances resolution by 4dB-lOdB. By using this result, the possibility to detect even minute tumor is demonstrated.

  • PDF

디지털 휴대용 생체 기록계 개발에 관한 연구 (A Study on Developement of Portable Digital Bio-signal Recorder)

  • 이호재;전태의;윤충화;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.109-113
    • /
    • 1993
  • In this paper, we devised a simple portable digital recorder for a day life ECG signal recording. The system are consisted of ECG amp. part, signal conditioning part. A/D converter, data compression part and digital memory part. An ADPCM algorithm used at data compress part for 50% of data reduction. The maximum lengths of recording times take 3 hours in 1 mega byte memory.

  • PDF

JADE알고리즘의 개선에 관한 연구 (A Study on the Improvement of the JADE Algorithm)

  • 윤형로;이진술;전대근;이경중
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.305-310
    • /
    • 2003
  • In this paper, we proposed an IJADE(Improved joint approximate diagonalisation of eigenmatrices) which use high order statistics instead of second order statistics for data whitening. For simulation, we artificially construct signals mixed with two ECG signals, 60Hz power line interference and 16Hz sine signal and then put them into a JADE and an IJADE. To evaluate the performance of separated ECG signal in each algorithm, we have adopted indices such as kurtosis, standard deviation ratio, correlation coefficient and euclidean distance. As a results, IJ ADE showed theimproved performances as kurtosis of $2\%,$ standard deviation ratio of 0.2194, and Euclidean distance of 0.07 except correlation coefficient showing similar value. In conclusion, the proposed IJADE showed a good performance in separating ECG and a possibilities in applying to the various biological signal.

마이크로 콤퓨터를 이용한 뇌파 스파이크의 검출에 관한 연구 (A Microcomputer-based EEG Spike Detection System)

  • 김종현;박상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제2권2호
    • /
    • pp.83-88
    • /
    • 1981
  • A method of detecting abnormal spikes occuring in the EEG of subjects suffering from epilepsy is studied. The detection scheme is to take the first derivative of EEG and to determine if it exceed some threshold value. This study is focused on the digital signal processing for detecting abnormal spikes using microcomputer.

  • PDF

초음파 펄스 도플러 시스템의 Stationary Conceler에 대한 연구 (A Study on the Stationary Canceler in the Ultrasonic Pulse Doppler System)

  • 김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권1호
    • /
    • pp.47-54
    • /
    • 1985
  • In this paper, clutter in ultrasound pulsed Doppler system is analyzed mathematically. And stationary canceler which reduce the clutter is designed. The operating characteristics of the stationary canceler is investigated in body (in vivo) by audio signal and spectrum analyzer.

  • PDF