• Title/Summary/Keyword: Biological signal

Search Result 1,271, Processing Time 0.025 seconds

Postnatal Development of Echolocation Vocalizations in the Serotine Bat, Eptesicus serotinus (Chiroptera: Vespertilionidae) (문둥이박쥐(Eptesicus serotinus)의 생후 반향정위 발성 발달에 관한 연구)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lim, Chun-Woo;Cha, Jin-Yeol
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.858-864
    • /
    • 2015
  • Developmental changes in the vocal signals of serotine bats (Eptesicus serotinus) during their infancy were examined in this study. The analysis was conducted on 4 infant serotine bats from 1 to 40 days after their birth. Pulse duration (PD), pulse interval (PI), peak frequency (PF), maximum frequency ($F_{MAX}$), minimum frequency ($F_{MIN}$), and bandwidth (BW) were measured. As the bats grew, their vocalizations became increasingly consistent and similar to those of adults. For infant bats, PD and PI decreased as they grew older, whereas PF, $F_{MAX}$, $F_{MIN}$, and BW increased. The greatest change in vocalizations was observed between the $10^{th}$ and $20^{th}$ days after birth. Also, PF, $F_{MAX}$, $F_{MIN}$ and BW, which describe sound frequency, increased dramatically during the period between the $10^{th}$ and the $20^{th}$ days. In contrast, the greatest change in PD occurred between the $30^{th}$ and $40^{th}$ days after birth. The results collected in this study suggest that frequency increased as the contraction ability of the muscles developed by around 20 days of age. Muscle relaxation ability, which is related to PD, was found to develop significantly at 30 to 40 days of age. According to the results of this study, although 40 day-old infant bats are not yet able to fly, their vocal signals were similar to those of adults. This indicates that vocal development and flying activity develop separately in young bats.

The activity of antioxidants and suppression of cancer cell proliferation in extracts of Orostachys japonicus A. Berger (바위솔 추출물의 항산화활성 및 암세포 증식억제)

  • Kim, Chung-Hyun;Park, Jae-Ho;Lim, Jong-Kuk;Lee, Kon-Joo;Chung, Gyu-Young;Jeong, Hyung-Jin
    • Korean Journal of Medicinal Crop Science
    • /
    • v.11 no.1
    • /
    • pp.31-39
    • /
    • 2003
  • The antioxidative activities and biological properties in the EtOAc extracts and purified extracts of Orostachys japonicus were measured by assay of DPPH, xanthine/xanthine oxidase and mammalian cells(2-12). Scavenging of DPPH radical and inhibition of xanthine/xanthine oxidase of EtOAc extracts were showed the highest activity in the arable land and in September. The S-4 fraction showed the highest activity among the silica-gel column chromatography fractions. LH-4 fraction showed higher activity than the other fractionsins in assay of DPPH and xanthine/xanthine oxidase. Fatty acids and phenolic compounds were identified by GC/MS and main compounds were 1,2,3-benzenetriol, alpha-androsta-7,14-diene in LH-4 fraction. The activities of POD and SOD in samples havested on different habitats were high such as arable land> intermountain> seashore. That of POD and SOD in crude extracts of late stage were higher than early stage. Isozyme bands of crude extracts samplinged in all habitats and all growing stages showed two bands and the signal intensity showed strongly according to passage of growing stage. The purified extracts of LH-4 fraction showed excellent inhibition effect in proliferation of HL-60 cells and markedly suppressed colony formation in mouse fibroblast cells. Dose response between partially purified extracts(400ppm) and negative control did not produced statistically significant reduction in colony formation.

Design and Implementation of IEEE 11073/HL7 Translation Gateway Based on U-Healthcare Application Service for M2M (M2M을 위한 U-헬스케어 응용 서비스 기반 IEEE 11073/HL7 변환 게이트웨이 설계 및 구현)

  • Chun, Seung-Man;Nah, Jae-Wook;Park, Jong-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.275-286
    • /
    • 2011
  • As the 21st century paradigm of healthcare service changes from post-therapeutic treatment to disease prevention and management in advance, the M2M-based u-healthcare application service is increasingly important. M2M-based u-healthcare application service uses mobile handsets equipped with sensors to measure vital information, and the medical staff in remote locations can manage the health of the patient or the public in real time. In this paper, IEEE/HL7 translation gateway, utilizing the gateway based on M2M u-healthcare application service structure, which is based on international standards, has been designed and implemented. Specifically, the gateway between ISO/IEEE 11073 standards and ANSI HL7 has been developed. The former defines the protocol for the exchange of information between the agent device and the manger devices for measuring and handling biological signal, and the latter defines the application layer protocol for the exchange of various healthcare information systems. Finally, in order to demonstrate the functionality of the proposed architecture, the M2M-based U-healthcare application service based on IEEE/HL7 translation gateway, utilizing the gateway, has been developed which can measure, collect and process a variety of vital signs such as ECG or SpO2.

Evaluation for Optimal HUD Location on a Train Using EEG (뇌파를 이용한 열차 최적의 HUD위치 평가)

  • Wang, Chang-Won;Kim, Yong-Kyu;Min, Se-Dong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.11
    • /
    • pp.985-993
    • /
    • 2014
  • This paper suggested a new evaluation method for optimal HUD position through a correlation based on between biological signal as and statistical analysis which using (Electroencephalogram, EEG) and ANOVA. This experiment was conducted two kinds of method to evaluate the optimal HUD position. At first, visual stimulus suggested from six different positions(the top and the bottom of the left, the top and the bottom of the center and the top and the bottom of the right on the screen) in laboratory and an object image was shown for 30 seconds in a screen which has $235{\times}197cm2$ size. And second, HUD image was configured from three different positions and an object image was shown for 30 seconds in a screen. EEG, which used ${\alpha}$-wave and ${\beta}$-wave for evaluate an emotional stability, were measured from Fp1, Fp2, F7 and F8 channel based on ten to twenty electrode system. From the result in laboratory, F7 ${\beta}$-wave was shown statistically significant to significance probability of 0.006 and between ${\alpha}$-wave and ${\beta}$-wave were showed a negative correlation(r=-0.190). Also, Both the top of left and the bottom of center were showed lower ${\beta}$-wave than the bottom of right. From the result in railway simulator, Fp1 ${\beta}$-wave was appeared statistically significant as significance probability of 0.033 and it was showed lower ${\beta}$-wave than center. The outcome of this study will be helpful about evaluation of optimal HUD position through correlation between alpha wave and beta wave.

Design of an Optimal Adaptive Filter for the Cancellation of M-wave in the EMG Controlled Functional Electrical Stimulation for Paralyzed Individuals (마비환자의 근전도제에기능적전기자극을 위한 M-wave 제거용 최적적응필터 설계)

  • Yeom Hojoon;Park Youngcheol;Lee Younghee;Yoon Youngro;Shin Taemin;Yoon Hyoungro
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.479-487
    • /
    • 2004
  • Biopotential signals have been used as command in systems using electrical stimulation of motor nerves to restore movement after an injury to the central nervous system (CNS). In order to use the voluntary EMG (electromyography) among the biopotentials as a control signal for the electrical stimulation of the same muscle for CNS injury patients, it is necessary to remove M-wave of having high magnitude from raw data. We designed an optimal filter for removing the M-wave and preserving the voluntary EMG and showed that the optimal filter is eigen filter. We also proved that the previous method using the prediction error filter(PEF) is a suboptimal filtering in the sense of preserving the voluntary EMG. On basis of the data obtained from a model for M-wave and voluntary EMG and from actual CNS injury patients, with false-positive rate analysis, the proposed adaptive filter showed a very promising performance in comparison with previous method.

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.

Grand Average in MEG and Crude Estimation of Anatomical Site (뇌자도에서 전체 평균과 이를 이용한 해부학적 위치 추정)

  • Kwon H.;Kim K.;Kim J. M.;Lee Y. H.;Park Y. K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.575-580
    • /
    • 2004
  • In this work, a method is presented to find an anatomical site of a current source crudely in a standard brain using grand average of MEG data. Minimum norm estimation algorithm and truncated singular value decomposition were applied to calculate the distributed sources that can reproduce the measured signals. Grand average over all subjects was obtained from the transformed signals, which would be detected in a standard sensor plane by the obtained distributed current sources. In the simulation study, it was shown that the localized dipole using the grand average is consistent with the mean location of localized dipoles of all subjects within several mm even with large inter-individual differences of sensor positions. This result suggests that the mean location of low level signal source can be estimated as a dipole source in grand average and it was confirmed in the localization of the current source of N100m. when the localized dipole is registered on a standard brain. This result also suggests that the activity region obtained from grand average can be crudely estimated on a standard brain using the source location of the N100m as a reference point.

Development of an EEG Software for Two-Channel Cerebral Function Monitoring System (2채널 뇌기능 감시 시스템을 위한 뇌파 소프트웨어의 개발)

  • Kim, Dong-Jun;Yu, Seon-Guk;Kim, Seon-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 1999
  • This paper describes an EEG(electroencephalogram) software for two-channel cerebral function monitoring system to detect the cerebral ischemia. In the software, two-channel bipolar analog EEG signals are digitized and from the signals various EEG parameters are extracted and displayed on a monitor in real-time. Digitized EEG signal is transformed by FFT(Fast Fourier transform) and represented as CSA(compressed spectral array) and DSA(density spectral array). Additional 5 parameters, such as alpha ratio, percent delta, spectral edge frequency, total power, and difference in total power, are estimated using the FFT spectra. All of these are effectively merged in a monitor and displayed in real-time. Through animal experiments and clinical trials on men, the software is modified and enhanced. Since the software provides raw EEG, CSA, DSA, simultaneously with additional 5 parameters in a monitor, it is possible to observe patients multilaterally. For easy comparison of patient's status, reference patterns of CSA, DSA can be captured and displayed on top of the monitor. And user can mark events of surgical operation and patient's conditions on the software, this allow him jump to the points of events directly, when reviewing the recorded EEG file afterwards. Other functions, such as forward/backward jump, gain control, file management are equipped and these are operated by simple mouse click. Clinical tests in a university hospital show that the software responds accurately according to the conditions of patients and medical doctors can use the software easily.

  • PDF

A Study on Projection Image Restoration by Adaptive Filtering (적응적 필터링에 의한 투사영상 복원에 관한 연구)

  • 김정희;김광익
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.119-128
    • /
    • 1998
  • This paper describes a filtering algorithm which employs apriori information of SPECT lesion detectability potential for the filtering of degraded projection images prior to the backprojection reconstruction. In this algorithm, we determined m minimum detectable lesion sized(MDLSs) by assuming m object contrasts uniformly-chosen in the range of 0.0-1.0, based on a signal/noise model which provides the capability potential of SPECT in terms of physical factors. A best estimate of given projection image is attempted as a weighted combination of the subimages from m optimal filters whose design is focused on maximizing the local S/N ratios for the MDLS-lesions. These subimages show relatively larger resolution recovery effect and relatively smaller noise reduction effect with the decreased MDLS, and the weighting on each subimage was controlled by the difference between the subimage and the maximum-resolution-recovered projection image. The proposed filtering algoritym was tested on SPECT image reconstruction problems, and produced good results. Especially, this algorithm showed the adaptive effect that approximately averages the filter outputs in homogeneous areas and sensitively depends on each filter strength on contrast preserving/enhancing in textured lesion areas of the reconstructed image.

  • PDF

A Method for Protein Functional Flow Configuration and Validation (단백질 기능 흐름 모델 구성 및 평가 기법)

  • Jang, Woo-Hyuk;Jung, Suk-Hoon;Han, Dong-Soo
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.4
    • /
    • pp.284-288
    • /
    • 2009
  • With explosively growing PPI databases, the computational approach for a prediction and configuration of PPI network has been a big stream in the bioinformatics area. Recent researches gradually consider physicochemical properties of proteins and support high resolution results with integration of experimental results. With regard to current research trend, it is very close future to complete a PPI network configuration of each organism. However, direct applying the PPI network to real field is complicated problem because PPI network is only a set of co-expressive proteins or gene products, and its network link means simple physical binding rather than in-depth knowledge of biological process. In this paper, we suggest a protein functional flow model which is a directed network based on a protein functions' relation of signaling transduction pathway. The vertex of the suggested model is a molecular function annotated by gene ontology, and the relations among the vertex are considered as edges. Thus, it is easy to trace a specific function's transition, and it can be a constraint to extract a meaningful sub-path from whole PPI network. To evaluate the model, 11 functional flow models of Homo sapiens were built from KEGG, and Cronbach's alpha values were measured (alpha=0.67). Among 1023 functional flows, 765 functional flows showed 0.6 or higher alpha values.