• Title/Summary/Keyword: Biological properties

Search Result 2,877, Processing Time 0.031 seconds

Nitrite Scavenging and Alcohol Metabolizing Activities of Hot Water Extract from Makgeoly and Its Angiotensin Converting Enzyme Inhibitory Effect (막걸리 열수 추출물의 아질산염 소거능, 알코올 분해능 및 angiotensin converting enzyme 저해 효과)

  • Cho, Eun-Kyung;Kim, Hee-Yeon;Byeon, Hyeon-Ji;Kim, Soo-Won;Choi, Young-Ju
    • Journal of Life Science
    • /
    • v.20 no.5
    • /
    • pp.768-774
    • /
    • 2010
  • In this study, we investigated the antioxidant activities, alcohol metabolizing activities, nitrite scavenging ability, angiotensin converting enzyme (ACE), and elastase inhibitory effects of hot water extract from Makgeoly (HWM). Antioxidant activities were measured by using 2,2.diphenyl.1.picryl.hydrazyl (DPPH) free radical scavenging activity and SOD (superoxide dismutase).like activity. The DPPH radical scavenging activity and SOD.like activity of HWM were remarkably increased in a dose.dependent manner and were 48.0% and 98.7% at 10 mg/ml, respectively. To determine the influence of HWM on alcohol metabolizing activity, the generating activities of reduced.nicotinamide adenine dinucleotide (NADH) by alcohol dehydrogenase (ADH) and aldehyde dehydrogenase (ALDH) were measured. The facilitating rates of ADH and ALDH activity by HWM were remarkably increased in a dose.dependent manner and were 70.2% and 64.1% at 10 mg/ml, respectively. The inhibitory activity against angiotensin converting enzyme (ACE) of HWM was increased in a dose.dependent manner and was 74.2% at 10 mg/ml. The nitrite scavenging ability of HWM showed the most remarkable effect at pH 1.2 and 2 mg/ml. These results indicated that HWM may have valuable biological properties owing to their antioxidant activities, ADH and ALDH activity, nitrite scavenging ability, and ACE inhibitory activity.

The activity of antioxidants and suppression of cancer cell proliferation in extracts of Orostachys japonicus A. Berger (바위솔 추출물의 항산화활성 및 암세포 증식억제)

  • Kim, Chung-Hyun;Park, Jae-Ho;Lim, Jong-Kuk;Lee, Kon-Joo;Chung, Gyu-Young;Jeong, Hyung-Jin
    • Korean Journal of Medicinal Crop Science
    • /
    • v.11 no.1
    • /
    • pp.31-39
    • /
    • 2003
  • The antioxidative activities and biological properties in the EtOAc extracts and purified extracts of Orostachys japonicus were measured by assay of DPPH, xanthine/xanthine oxidase and mammalian cells(2-12). Scavenging of DPPH radical and inhibition of xanthine/xanthine oxidase of EtOAc extracts were showed the highest activity in the arable land and in September. The S-4 fraction showed the highest activity among the silica-gel column chromatography fractions. LH-4 fraction showed higher activity than the other fractionsins in assay of DPPH and xanthine/xanthine oxidase. Fatty acids and phenolic compounds were identified by GC/MS and main compounds were 1,2,3-benzenetriol, alpha-androsta-7,14-diene in LH-4 fraction. The activities of POD and SOD in samples havested on different habitats were high such as arable land> intermountain> seashore. That of POD and SOD in crude extracts of late stage were higher than early stage. Isozyme bands of crude extracts samplinged in all habitats and all growing stages showed two bands and the signal intensity showed strongly according to passage of growing stage. The purified extracts of LH-4 fraction showed excellent inhibition effect in proliferation of HL-60 cells and markedly suppressed colony formation in mouse fibroblast cells. Dose response between partially purified extracts(400ppm) and negative control did not produced statistically significant reduction in colony formation.

Polydiacetylene-Based Chemo-/Biosensor of Label Free System with Various Sensing Tools (다양한 감지 방법을 갖고 있는 폴리디아세틸렌 기반 비표지 화학/바이오센서)

  • Park, Hyun-Kyu;Park, Hyun-Gyu;Chung, Bong-Hyun
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.409-413
    • /
    • 2007
  • Polydiacetylene(PDA)-based sensors possess a number of properties that can be successfully applied for label-free detection system. PDA is one of the most attractive color-generating materials, with growing applications as sensors. Here we introduce various PDA-based devices, used as biosensor, chemosensor, thermosensor, and optoelectronics sensor. In general, PDA liposomes and films are closely packed and properly designed for polymerization via 1,4-addition reaction to form an ene-yne alternating polymer chain. PDA-based two/three dimensional structures have been used for colorimetric or fluorescent devices, sensing biological as well as chemical components. This color-generating material also present a very high charge carrier mobility, allowing its application as field-effect transistor (FET). The immobilized PDA structures or films have distinct advantages for the detection of low concentration target molecules over the aqueous solution-based detection systems. In the present review, reported detection methods by using various PDA structures are summarized with updated references.

A New Design of the Interrogating Waves for Medical Ultrasonic Imaging Based on Wavelets and Subband Filter Banks: A Simulation Study (의료용 초음파 영상시스템을 위한 Wavelet 과 Subband Filter Bank 에 기반한 새로운 탐침 파형의 설계: A Simulation Study)

  • Yang Yoon Seok
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.431-438
    • /
    • 2004
  • Medical ultrasonic imaging is a useful imaging facility known to be most safe and easy. It enables physicians to observe the inside structures of the bodies, blood flow, and motions of internal organs. Some physical properties of biologic tissues can also be estimated from backscattered sounds. However, the ultrasonic pulses interrogating the living organisms leave their footprints in the returning signals during imaging. Some significant details are buried in the footprints and their overlaps from adjacent particles. These distortions also decrease the quality of the images. Many research efforts have been made to enhance the image quality and to recover the acoustic information in various ways. In this study, a new interrogation method based on the wavelet and subband filter bank is proposed. It adopts the subband wavelet filters satisfying the perfect-reconstruction (PR) conditions as the interrogating pulses to restore the details useful in tissue characterization and to enhance the image quality. The proposed method was applied to two types of simulations of ultrasonic imaging. The results showed its ability to restore the detailsin the simulated interrogation of biologic tissues, and verified the improved image quality in the simulated imaging of general ultrasonic phantom compared with the conventional method.

A New Algorithm for Extracting Fetal ECG from Multi-Channel ECG using Singular Value Decomposition in a Discrete Cosine Transform Domain (산모의 다채널 심전도 신호로부터 이산여현변환영역에서 특이값 분해를 이용한 태아 심전도 분리 알고리듬)

  • Song In-Ho;Lee Sang-Min;Kim In-Young;Lee Doo-Soo;Kim Sun I.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.589-598
    • /
    • 2004
  • We propose a new algorithm to extract the fetal electrocardiogram (FECG) from a multi-channel electrocardiogram (ECG) recorded at the chest and abdomen of a pregnant woman. To extract the FECG from the composite abdominal ECG, the classical time-domain method based on singular value decomposition (SVD) has been generally used. However, this method has some disadvantages, such as its high degree of computational complexity and the necessary assumption that vectors between the FECG and the maternal electrocardiogram (MECG) should be orthogonal. The proposed algorithm, which uses SVD in a discrete cosine transform (DCT) domain, compensates for these disadvantages. To perform SVD with lower computational complexity, DCT coefficients corresponding to high-frequency components were eliminated on the basis of the properties of the DCT coefficients and the frequency characteristics of the FECG. Moreover, to extract the pure FECG with little influence of the direction of the vectors between the FECG and MECG, three new channels were made out of the MECG suppressed in the composite abdominal ECG, and the new channels were appended to the original multi-channel ECG. The performance of the proposed algorithm and the classical time-domain method based on SVD were compared using simulated and real data. It was experimentally verified that the proposed algorithm can extract the pure FECG with reduced computational complexity.

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF

Development of Target-Controlled Infusion System in Plasma Concentration. PART1 : Establishment of Pharmacokinetic Model and Verification (혈중 목표 농도 자동 조절기(TCI) 개발 PART1 : 약동학적 모델의 수립과 검증)

  • 안재목;길호영
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.341-349
    • /
    • 2002
  • The target controlled infusion(TCI) pump system is a logical approach to the development of improved administration techniques of an intravenous anaesthetic agent. The principle of TCI system is based on an understanding of the pharmacokinetic properties, three or four compartment model. The TCI system is optimal and flexible control of the plasma drug concentration. But the clinical goal is always to achieve a therapeutic drug effect, not a therapeutic concentration. So we developed the algorithm to target the concentration at the site of drug effect rather than the concentration in the plasma. If impulse drug is inputted into body, the decline of plasma concentration with time is shown, resulting in the expression of the differential equation. Therefore, we must reformulate our three-compartment model as four-compartment model with the effect compartment. And we tested plasma targeting and effect targeting algorithm by computer simulation using four-compartment model. So we developed the TCI capable of applying all intravenous drugs by adjusting individual pharmacokinetic parameters independently.

Assessment of the possibility as Cosmetics Materials by Brown algae from Jeju Island Using Supercritical Fluid System (초임계 유체 기술을 이용한 제주산 갈조류의 화장품 소재로서의 가능성 평가)

  • Choi, Ha-Young;Choi, Na-Young;Shon, Myung-Soo;Kim, Duk-Soo;Lee, Hyun-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.698-704
    • /
    • 2020
  • Although various biological extracts derived from the resources from Jeju are currently being developed for cosmetic materials, few studies using Brown algae from Jeju have been conducted. This study identified materials with high antioxidant levels and examined their whitening effects to assess their feasibility as potential cosmetic resources. Brown algae from Jeju (Undaria pinnatifida (Harvey) Suringar, Laminaria japonica, Ecklonia cava, Hizikia fusiforme (Harvey) Okamura (HF), and Sargassum fulvellum (Turner) C. Agardh (SF) were processed using a supercritical fluid system at 50℃ and 400 bar, and their total phenol content, antioxidant activity, tyrosinase inhibition, and primary skin irritation were measured. Of all the samples, only SF using the supercritical fluid system (SFS) displayed concentration-dependent behavior for the total phenol content (p<0.05). Among the samples, the antioxidant activity of SFS was significantly higher (p<0.05) and the one increased at higher concentrations (p<0.05). On the other hand, tyrosinase was inhibited to a greater extent with HF than the others. The primary skin irritation tests showed that none of the samples were skin irritants. This study confirmed the feasibility of using Phaeophyceae from Jeju as potential cosmetic materials, where the samples can be selected and utilized based on the required physicochemical properties.

Synthesis and Characteristics of Partially Fluorinated Poly(vinylidene fluroide)(PVDF) Cation Exchange Membrane via Direct Sulfonation (직접술폰화반응에 의한 부분불소화 Poly(vinylidene fluroide)(PVDF) 양이온교환막의 합성 및 특성)

  • Kang, Ki Won;Hwang, Taek Sung
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.406-414
    • /
    • 2015
  • In this study, partially fluorinated cation exchange membranes were prepared by direct sulfonation of Poly(VDF-co-hexafluoropropylene) copolymers (PVDF-co-HFP) followed by a casting method for application in the Membrane capacitive deionization (MCDI). The structure of sulfonated PVDF-co-HFP (SPVDF) was confirmed by Fourier-transform infrared (FT-IR) and $^1H$ Nuclear magnetic resonance ($^1H$ NMR) analysis. For quantitative analysis of the chemical composition, the X-ray Photoelectron Spectroscopy (XPS) was used. The membrane properties such as water uptake, ion exchange capacity and electrical resistance were measured. It was suggested that the optimum direct sulfonation condition of PVDF-co-HFP ion exchange membranes was $60^{\circ}C$ and 7 hours for temperature and duration of sulfonation, respectively. The water uptake of the SPVDF ion exchange membrane was 21.5%. The ion exchange capacity and electrical resistance were 0.89 meq/g and $3.70{\Omega}{\cdot}cm^2$, respectively. It was investigated that if it is feasible to apply these membranes in MCDI at various cell potentials (0.9~1.5 V) and initial flow rates (10~40 mL/min). In the MCDI process, the maximum salt removal rate was 62.5% in repeated absorption-desorption cycles.

Variation of Single Gas ($SF_6$, $N_2$, $O_2$, $CF_4$) Permeance through Hollow Fiber Polymeric Membranes Depending on Temperature and Pressure (중공사 고분자 분리막을 통한 단일기체($SF_6$, $N_2$, $O_2$, $CF_4$) 투과플럭스의 온도와 압력에 따른 변화특성)

  • Lee, Min-Woo;Lee, Soon-Jae;Kim, Han-Byul;Kim, Sung-Hyun;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.23-34
    • /
    • 2012
  • In this study, we investigated the permeation property of single gases ($N_2$, $O_2$, $SF_6$, $CF_4$ through hollow fiber polymeric membrane (PSF, PC, PI) as a function of pressure and temperature to decide operating condition for $SF_6$ gas separation process. The results showed the gas permeation varied differentlydepending on the properties of gases and membrane. When permeance of each gases was represented as a function of temperature and pressure in 3 dimensional space, the surface of permeance was shown approximately flat. Thus, we established permeance models with forms of first-and second-order polynomial. These two models showed high goodness of fit. This indicates that the two polynomial models have enough applicability to predict the gas separation process.