• Title/Summary/Keyword: Bio-signal Measurement

Search Result 160, Processing Time 0.024 seconds

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Research of Non-integeral Spatial Interpolation for Precise Identifying Soybean Location under Plastic Mulching

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.156-156
    • /
    • 2017
  • Most crop damages have been occurred by vermin(e.g., wild birds and herbivores) during the period between seeding and the cotyledon level. In this study, to minimize the damage by vermin and acquire the benefits such as protection against weeds and maintenance of water content in soil, immediately vinyl mulching after seeding was devised. Vinyl mulching has been generally covered with black color vinyl, that crop seeding locations cannot be detected by visible light range. Before punching vinyl, non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. For this study, the spline method was relatively faster than the other polynomial interpolation methods, because it has a lower maximum order of formulation when using a system such as the tridiagonal linear equation system which provided the capability of real-time processing. The temperature distribution corresponding to the distance between the crops was 10 cm, and the more clearly the leaf pattern of the crop was visually confirmed. The frequency difference was decreased, as the number of overlapped pixels was increased. Also the wave pattern of points where the crops were recognized were reduced.

  • PDF

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

A Study on the Implementation of Mobile Healthcare System using Hybrid App (하이브리드 앱을 이용한 모바일 헬스케어 시스템 구현에 관한 연구)

  • Cho, Yang-Hyun;Kim, Sung Wan;Jeong, Pil-Seong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.503-514
    • /
    • 2013
  • Mobile Healthcare is a new type of health care services for managing health and life irrespective of time and space by uniting IT and BT. For this service bio-signal measurement using WBAN, and data analysis and monitoring technologies based on mobile devices are essential. Generally, however, mobile application has low compatibility because of the features of mobile platform, we have to redevelop it to support the corresponding platform. In this paper we introduce a Mobile Healthcare System which can function as gateway and monitoring based on hybrid app to create ubiquitous healthcare monitoring system compatible with various mobile devices by overcoming the difference of platforms. The proposed system consists of sensor composition part, monitoring composition part, and server composition part.

Analysis on the Depth of Anesthesia by Using EEG and ECG Signals

  • Ye, Soo-Young;Choi, Seok-Yoon;Kim, Dong-Hyun;Song, Seong-Hwan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.299-303
    • /
    • 2013
  • Anesthesia, which started being used to remove pain during surgery, has become itself one of the major concerns to be considered during surgery. While actual anesthesia is being performed, patients tend to have unpleasant experiences, due to wakening that accompanies pain, or wakening that does not accompany pain. Since this awakening during anesthesia is a most unpleasant experience in a patient's life, evaluating the depth of anesthesia during surgery is essential for patients to avoid this experience. Although there has been much effort on the understanding and measurement of the depth of anesthesia, while various researches were performed on the need of anesthesia, the development of an indicator that could objectively evaluate the depth of anesthesia, other than by using the patient's vital signs, is still inadequate. Therefore, this study was to develop an objective indicator by using EEG and ECG, which are essentially measured during the surgery, to evaluate the depth of anesthesia. The experiment was performed by taking patients who require a relatively short operation time, and general inhalation anesthetics among surgical patients in obstetrics and gynecology as the subjects of experiment, to measure the EEG and ECG signals of patients under anesthetics. The result showed that SEF using EEG and LF, HF using ECG signal and correlation dimension analysis parameter were valuable parameters that could measure the depth of anesthesia, by the stage of anesthesia.

Design and Construction of Integrated Database for Contents Development of Pulse Analysis System (맥진기 컨텐츠 개발을 위한 통합 데이터베이스 설계 및 구축)

  • So, Ji-Ho;Jeon, Young-Ju
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.137-142
    • /
    • 2017
  • The development of medical devices based on the theory of tranditional Korean medicine is increasing due to population aging and emerging demand for medical services. Various clinical trials are being conducted to ensure the clinical effectiveness of the developed medical devices, and the importance of systematic management of variously collected information in this process is increasing. In this paper, we designed and constructed the database that can systematically manage the medical information of the patient and the pulse measurement information in conducting clinical trials by using pulse analysis system which is a representative diagnostic method of traditional Korean medicine. The constructed database can be efficiently used for the verification of existing algorithms or developing new algorithms through the quality control of various information and measured data on clinical trials. It also has several advantages in the control of clinical data. The results of this study can contribute to the establishment of Korean medical device data standard for the construction of integrated database management system that can share information with different kind of pulse analysis system and other bio-signal measuring devices.

Hypertension Monitoring and Notification Service based on Context Information (상황정보 기반의 고혈압 모니터링 및 알림 서비스)

  • Lee, Young-Ho;Kim, Jong-Hun;Shin, Da-Hye;Jung, Eun-Young;Park, Dong-Kyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.57-66
    • /
    • 2011
  • In recent years, health management services have been increased according to the increase in interests on health and the development of information technology (IT) based on increases in advanced ages and chronic disease patients. Thus, it requires the monitoring of health conditions and the specialized healthcare services not only in a hospital but also their own home. This study provides the specific notification services related to the context information based on users' bio signal data and the notification services of specific patients and attempts to develop a hypertension monitoring system and a notification service system according to indexes. Because this system considers the context of users by differing it from the conventional monitoring services, it makes possible to obtain more exact measurement values. In addition, it is able to reduce certain health risks through managing specific patients and based on living indexes. Also, it can provide more customized services to users due to the exact and finely classified services.

Real Time Scale Measurement of Inorganic Phosphate Release by Fluorophore Labeled Phosphate Binding Protein (형광단이 붙어 있는 인산결합 단백질에 의한 인산 배출의 실시간 측정)

  • Jeong Yong-Joo
    • Journal of Life Science
    • /
    • v.15 no.6 s.73
    • /
    • pp.935-940
    • /
    • 2005
  • Fluorescence change of coumarin labeled phosphate binding protein (PBP-MDCC) was monitored to measure the amount of released inorganic phosphate ($P_{i}$) during nucleoside triphosphate (NTP) hydrolysis reaction. After purification of PBP-MDCC, fluorescence emission spectra showed that fluorescence responded linearly to $P_{i}$ up to about 0.7 molar ratio of $P_{i}$ to protein. The correlation of fluorescence signal and $P_{i}$ standard was measured to obtain [$P_{i}$] - fluorescence intensity standard curve on the stopped-flow instrument. When T7 bacteriophage helicase, double-stranded DNA unwinding enzyme using dTTP hydrolysis as an energy source, reacted with dTTP, the change of fluorescence was able to be converted to the amount of released $P_{i}$ by the $P_{i}$ standard curve. $P_{i}$ release results showed that single-stranded Ml3 DNA stimulated dTTP hydrolysis reaction several folds by T7 helicase. Instead of end point assay in NTP hydrolysis reaction, real time $P_{i}$-release assay by PBP-MDCC was proven to be very easy and convenient to measure released $P_{i}$.

Correlation between Stories and Emotional Responses for American Movies (영화 스토리와 관객 감성반응과의 상관성에 대한 연구)

  • Woo, Jeong-Gueon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.7
    • /
    • pp.13-19
    • /
    • 2021
  • While watching the movie, the audience shows various emotional reactions. Emotional reactions such as sadness and anger, joy and anger appear depending on the storyline of the film. This aspect can be seen through the audience's brain wave response. This study is to examine the relationship between the movie story development and the movie story development through brain wave measurement of the emotional reaction of the audience in situations and events occurring in the movie development. Four American films, which represent each genre and are well known to many people, were selected for the study. These are of the adventure genre, of the animation genre, of the action genre, and of the drama genre. In order to measure the emotional response of these movies, four cases were set centered on the PPG of EEG and analyzed as a time series graph pattern. It can be seen that the emotional response on the graph has a certain relationship with the story development. It is expected that this study will help in selecting a genre when making a movie in the future, especially when deciding how to compose and develop a story, and it will help to induce the emotions of the audience.

High-Performance Compton SPECT Using Both Photoelectric and Compton Scattering Events

  • Lee, Taewoong;Kim, Younghak;Lee, Wonho
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1393-1398
    • /
    • 2018
  • In conventional single-photon emission computed tomography (SPECT), only the photoelectric events in the detectors are used for image reconstruction. However, if the $^{131}I$ isotope, which emits high-energy radiations (364, 637, and 723 keV), is used in nuclear medicine, both photoelectric and Compton scattering events can be used for image reconstruction. The purpose of our work is to perform simulations for Compton SPECT by using the Geant4 application for tomographic emission (GATE). The performance of Compton SPECT is evaluated and compared with that of conventional SPECT. The Compton SPECT unit has an area of $12cm{\times}12cm$ with four gantry heads. Each head is composed of a 2-cm tungsten collimator and a $40{\times}40$ array of CdZnTe (CZT) crystals with a $3{\times}3mm^2$ area and a 6-mm thickness. Compton SPECT can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction. The correct sequential order of the interactions used for image reconstruction is determined using the angular resolution measurement (ARM) method and the energies deposited in each detector. In all the results of simulations using spherical volume sources of various diameters, the reconstructed images of Compton SPECT show higher signal-to-noise ratios (SNRs) without degradation of the image resolution when compared to those of conventional SPECT because the effective count for image reconstruction is higher. For a Derenzo-like phantom, the reconstructed images for different modalities are compared by visual inspection and by using their projected histograms in the X-direction of the reconstructed images.