• 제목/요약/키워드: Bio-filtration

검색결과 137건 처리시간 0.028초

노면배수에 함유된 미량오염물질 및 제거에 관한 연구 (A Study on the Micropollutants and Removal of Micropollutants Contained in Road Runoff)

  • 김부길;박흥재;장성호
    • 한국환경과학회지
    • /
    • 제18권2호
    • /
    • pp.215-219
    • /
    • 2009
  • Micropollutants, which can be caused by imperfect combustion, are toxic chemical compound that flows into the river system after being contained in road runoff, a non-point source pollutant and accumulates in the body. The micropollutants that have characteristics such as toxicity, persistence, bio-accumulation, long-range transportation behave so similarly to micro particles that they can be removed by means of filtration or absorption. This study has examined the kinds and concentrations of micropollutants contained in deposited road particles. It has revealed that the kinds of micropollutants contained in the clarified supernatant liquid of deposited road particles are heavy metals and polycyclic aromatic hydrocarbons(PAHs) composed of two or three benzene rings, including naphthalene and acenaphthalene. Their concentrations have been shown to be low, with 0.418 mg/L, 0.058 mg/L, 0.104 mg/L, 0.014 mg/L, 0.00075 mg/L for Zn, Pb, Cu, Cr, Cd, respectively and 0.00156 mg/L and 0.00184 mg/L for naphthalene and acenaphthalene.

Purification and Characterization of Acetolactate Synthase from Barley

  • Chong, Chom-Kyu;Chang, Soo-Ik;Choi, Jung-Do
    • BMB Reports
    • /
    • 제30권4호
    • /
    • pp.274-279
    • /
    • 1997
  • Acetolactate synthase (ALS) catalyzes the first common step in the biosynthesis of branchedchain amino acids, valine, leucine, and isoleucine. ALS is the target site for several structually diverse classes of herbicides including sulfonylureas, imidazolinones. and triazolopyrimidines. We have purified ALS from etiolated barley shoots to homogeneity. The five major purification steps are ammonium sulfate fractionation, DEAE anion exchange, hydroxylapatite, Bio-Gel A gel filtration, and low pressure Mono-Q chrornatoqraphy. Approximately 170-fold purification was achieved and the yield was 0.45% of initial activity in the crude extract. Both SDS-PAGE and Western blot analysis showed a single polypeptide of ALS with an apparent molecular mass of 64 kDa. The result of nondenaturing gel electrophoresis with activity staining indicated that the molecular mass of its native form is approximately 225 to 250 kDa. The values of $K_m$ for pyruvate. pl. and optimum pH of ALS were determined to be 2.0 mM, 5.2. and 7.0. respectively Feedback inhibition studies showed that ALS is more susceptible to leucine than valine. And $IC_{50}$ value of Cadre, a class of irnidazolinones, is about $1.5\mu{M}$ for ALS.

  • PDF

교반식 퇴비화 암모니아가스의 부숙퇴비를 이용한 탈취성능 특성 (Performance Characteristics of Matured Compost Biofiltration of Ammonia Gas from the Agitated Composting)

  • 홍지형;박금주
    • 한국축산시설환경학회지
    • /
    • 제8권1호
    • /
    • pp.1-8
    • /
    • 2002
  • 실제 규모의 반밀폐 교반통기식 퇴비화 시스템에서 돈분과 톱밥의 혼합물을 퇴비화하는 과정에서 발생하는 암모니아가스의 탈취처리를 위하여 개방식 바이오필터 시스템을 제작하고 바이오필터로서 부숙퇴비를 이용하여 탈취시험을 수행하였다. 퇴비화 및 탈취과정에서 재료의 이화학적 특성 및 암모니아가스의 발생량을 측정하여 퇴비화의 특성 및 바이오필터 시스템의 성능을 분석하였다. 바이오필터의 암모니아가스 탈취효율은 2개월 평균 84%로 나타났으며 탈취재를 통과한 후의 암모니아가스의 농도는 최대 45ppm 이하로 나타나 허용농도 (50ppm) 범위에 있었다. 부숙퇴비는 교반통기식 퇴비화 시스템에서 발생하는 암모니아가스의 탈취재로 활용할 수 있는 것으로 나타났다.

  • PDF

제지폐수처리의 고분자 응집제 주입량 간이 결정법 (Simple Determination Method on Optimal Dosage of Polymer for Papermaking Wastewater Treatment)

  • 조준형;강미란;김해난
    • Journal of Forest and Environmental Science
    • /
    • 제30권1호
    • /
    • pp.85-90
    • /
    • 2014
  • Dewaterability, one of the important properties of wastewater sludge, was investigated using a simple capillary suction time (CST) measurement method. CST and SRF have a very close co-relation. It was convinced that CST method was quite effective, and compensating the time-consuming SRF of conventional drainage measuring method. It turned out that one could use the results of CST to find optimum flocculants ratio to improve drainage in wastewater treatment for the tissue paper production at a mill. Since the optimum ratio of flocculants could be determined with the value of CST and COD removal efficiency could be improved with precise ratio of flocculants. Thus, using CST for determining the optimum ratio of flocculants could be economical by reducing the amount of flocculants. Dewaterability might be measured within several seconds using the values of CST in a precise way. The dewaterability could also be useful in investigating the optimum ratio of flocculants.

Characteristic Features of an ${\alpha}-Galactosidase$ from Penicillium purpurogenum

  • Park, Gwi-Gun;Lee, Sang-Young;Park, Boo-Kil;Ham, Seung-Shi;Lee, Jin-Ha
    • Journal of Microbiology and Biotechnology
    • /
    • 제1권2호
    • /
    • pp.90-95
    • /
    • 1991
  • A ${\alpha}-galactosidase{\;}({\alpha}-D-galactoside$ galactohydrolase; EC 3.2.1.22) was purified from the culture filtrate of Penicillium purpurogenum by DEAE-cellulose column chromatography, gel filtration of Bio gel p-l00, and subsequent SP-Sephadex C-25 chromatography. The final preparation thus obtained showed a single band on polyacrylamide disc-gel and SDS-polyacrylamide gel electrophoresis. The molecular weight and isoelectric point were determined to be 63,000 and pH 4.0 by SDS-polyacrylamide gel electrophoresis and isoelectric focusing, respectively. The galactosidase exhibited maximum activity at pH 4.5 and $55^{\circ}C$, and was stable between pH 2 and 5, and also stable up to $40^{\circ}C$. The enzyme activity was not affected considerably by treatment with other metal compounds except mercuric chloride and silver nitrate. Copra galactomannan was finally hydrolyzed to galactose, mannose and mannobiose through the sequential actions of the purified galactosidase and mannanase from the same strain. The enzyme hydrolyzed melibiose and raffinose, but not lactose.

  • PDF

해수담수화 공정에서 역삼투막의 유기 막오염에 대한 SWRO 막의 화학세정 효율 평가 (Evaluation on Chemical Cleaning Efficiency of Organic-fouled SWRO Membrane in Seawater Desalination Process)

  • 박준영;홍성호;김지훈;정우원;남종우;김영훈;전민정;김형수
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.177-184
    • /
    • 2011
  • Membrane fouling is an unavoidable phenomenon in operation of seawater reverse osmosis (SWRO) and major obstacle for economic and efficient operation. When fouling occurs on the membrane surface, the permeate flux is decreased, on the contrary, the trans-membrane pressure (TMP) is increased, therefore operation and maintaining costs and potential damage of membranes are able to the pivotal risks of the process. Chemical cleaning process is essential to prevent interruptions for effective RO membrane filtration process. This study focused on proper chemical cleaning condition for polyamide RO membranes of 4 companies. Several chemical agents were applied for chemical cleaning under numbers of operating conditions. Additionally, a monitoring tool of FEEM as autopsy analysis method is adapted for the prediction of organic bio-fouling.

위성영상을 이용한 대청호 남조류의 공간 분포 맵핑 (Spatial Distribution Mapping of Cyanobacteria in Daecheong Reservoir Using the Satellite Imagery)

  • 백신철;박진기;박종화
    • 한국농공학회논문집
    • /
    • 제58권2호
    • /
    • pp.53-63
    • /
    • 2016
  • Monitoring of cyanobacteria bloom in reservoir systems is important for water managers responsible of water supply system. Cyanobacteria affect the taste and smell of water and pose considerable filtration problems at water use places. Harmful cyanobacteria bloom in reservoir have significant economic impacts. We develop a new method for estimating the cyanobacteria bloom using Landsat TM and ETM+ data. Developed model was calibrated and cross-validated with existing in situ measurements from Daecheong Reservoir's Water Quality Monitoring Program and Algae Alarm System. Measurements data of three stations taken from 2004 to 2012 were matched with radiometrically converted reflectance data from the Landsat TM and ETM+ sensor. Stepwise multiple linear regression was used to select wavelengths in the Landsat TM and ETM+ bands 1, 2 and 4 that were most significant for predicting cyanobacteria cell number and bio-volume. Based on statistical analysis, the linear models were that included visible band ratios slightly outperformed single band models. The final monitoring models captured the extents of cyanobacteria blooms throughout the 2004-2012 study period. The results serve as an added broad area monitoring tool for water resource managers and present new insight into the initiation and propagation of cyanobacteria blooms in Daecheong reservoir.

The Degradation of Chitin with Food Grade Papain

  • Han, Beom-Ku;You, Tak;Moon, Jong-Kook;Kim, Sae-Bom;Jo, Do-Hyun
    • Journal of Applied Biological Chemistry
    • /
    • 제43권4호
    • /
    • pp.246-249
    • /
    • 2000
  • We investigated the production of chitin oligosaccharides using food grade papain. A solution of commercial food grade papain (FGP) was dialyzed for 12 h before measuring its chitinolytic activity. The effects of enzyme concentration, reaction temperature, and pH on the endochitinase and $\beta$-N-acetylglucosaminidase activities and the thermostability of these enzymes were investigated. In adddition, the reaction products were analyzed with gel filtration on a Bio-Gel P2. The endochitinase activity was twentyfold higher than that of $\beta$-N-acetylglucosaminidase. The optimal endochitinase activity was at pH 3.0, while the maximal $\beta$-N-acetylglucosaminidase activity was at pH 6.0. The reaction product consisted mainly of the dimer of N -acetylglucosamine, with a small amount of its trimer. Under the experimental conditions, $120{\mu}g$ of chitin oligomers were obtained with 1 mg of FGP protein after an incubation of 2 h.

  • PDF

Influence of sludge solids content on sludge dewaterability using bioleaching

  • Wong, Jonathan W.C.;Zhou, Jun;Zhou, Lixiang;Kurade, Mayur B.;Selvam, Ammaiyappan
    • Advances in environmental research
    • /
    • 제3권3호
    • /
    • pp.199-206
    • /
    • 2014
  • Dewatering is an extremely important step in wastewater treatment process to reduce the final sludge volume in order to minimize the cost of sludge transportation and disposal. In the present study, the effect of different sludge solids content (1, 2 and 3.8%) on the dewaterability of anaerobically digested sludge using Acidithiobacillus ferrooxidans and Acidithiobacillus thiooxidans was studied. The pH reduction rate was higher during initial process in the sludge having low solids content, but after 48 h of bioleaching, similar pH of below 3 was observed with all the different solids content. Bio-oxidation rate of $Fe^{2+}$ was initially higher in sludge with low solids content, but 100% $Fe^{2+}$ was oxidized within 60 h in all the three treatment levels. Compared to the control, specific resistance to filtration was reduced by 75, 78 and 80% in the sludge with a solids content of 1, 2 and 3.8% respectively, showing improvement in dewaterability with an increase in sludge solids content. Sludge effluent quality and sludge settling rate were also improved in treatments with higher solids content after the bioleaching process.

Application and Maintenance Strategies for Eco-Friendly Facilities in Landscape Trees Nurseries

  • Young Sun Seok;O Man Kwon;Yun Eui Choi
    • Journal of Forest and Environmental Science
    • /
    • 제40권2호
    • /
    • pp.151-165
    • /
    • 2024
  • Recently, as the number of landscaping plant nurseries have increased, environmental problems such as topographical damage due to indiscriminate changes in land use, increased non-point pollution, and increased impervious areas are also occurring. In this study, we propose eco-friendly facilities and a detailed maintenance manual that can enhance the eco-friendliness and scenic beauty of landscaping plant nurseries that are increasingly located near cities. By exploring previous reports on eco-friendly facilities and related laws, we cataloged the types of eco-friendly facilities, and by referring to examples of eco-friendly facilities introduced in overseas cases and the environmental functions of agriculture, we cataloged the types of eco-friendly facilities suitable for introduction in plant nurseries. The selected facilities are rain gardens, tree boxes, vegetated filter beds, bio-retention, infiltration trench, infiltration tanks, permeable pavements, and sand filtration systems. The maintenance tasks of eco-friendly facilities were categorized and management plans were proposed, which is expected to be utilized as a basic data to prepare eco-friendly space planning and operation management plans when creating a landscape plant nurseries in the future.