• Title/Summary/Keyword: Bio signal

Search Result 668, Processing Time 0.028 seconds

Assessment of Driver's Emotional Stability by Using Bio-signals (생체신호 측정을 통한 운전자의 감정적 안정상태 평가)

  • Kim, Jung-Yong;Park, Ji-Soo;Yoon, Sang-Young
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.203-211
    • /
    • 2011
  • Objective: The aim of this study is to introduce a methodology to assess driver's emotion stability by using bio-signals. Background: Psychophysiological analysis of driver's behavior has been conducted to improve the driving safety and comfort. However, the variability of bio-signal and individual difference made it difficult to assess the psychophysiological status of drivers that can be expressed as emotional stability of drivers. Method: Two experimental studies were reviewed and summarized. New techniques assessing emotional stability of drivers were explained. Statistical concept and multidimensional space were used to identify the emotionally stable conditions. Conclusion: Psychophysiological approach can provide information of driver's emotional status. The experimental methodology and algorithm used in this study showed the possibility of parameterization of psychophysiological response. Application: Currently measured statistical and geometrical data can be further applied to develop an interactive device monitoring and reacting driver's emotion when driver experiences emotionally unstable or uncomfortable situation.

Longan (Dimocarpus longan Lour.) Fruit Extract Stimulates Osteoblast Differentiation via Erk1/2-Dependent RUNX2 Activation

  • Park, Seoyoung;Kim, Joo-Hyun;Son, Younglim;Goh, Sung-Ho;Oh, Sangtaek
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.6
    • /
    • pp.1063-1066
    • /
    • 2016
  • Longan (Dimocarpus longan Lour.) has been used as a traditional oriental medicine and possesses a number of physiological activities. In this study, we used cell-based herbal extract screening to identify longan fruit extract (LFE) as an activator of osteoblast differentiation. LFE up-regulated alkaline phosphatase (ALP) activity, induced mineralization, and activated Runx2 gene expression in MC3T3-E1 cells. Furthermore, treatment of MC3T3-E1 cells with LFE promoted the phosphorylation of extracellular signal-regulated kinase1/2 (Erk1/2); however, abrogation of Erk1/2 activation with PD98059 resulted in down-regulation of the phospho-SMAD1/5/8 and Runx2 levels, which in turn reduced the ALP activity. Our findings suggest that LFE exerts its osteogenic activity through activation of the ERK signaling pathway and may have potential as an herbal therapeutic or a preventive agent for the treatment of osteoporosis.

Construction of 19F-13C Solid-State NMR Probe for 400MHz Wide-Bore Magnet

  • Jeong, Ji-Ho;Park, Yu-Geun;Choi, Sung-Sub;Kim, Yongae
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2013
  • Various fluorine-containing materials are used in electronic devices like LCD display panels and Li-ion batteries. The structural conformation of fluorine in fluorinated materials is an important contributing factor that influences the chemical and physical properties. The conformation can be changed by heat and stress during manufacture or use. Understanding the conformational changes is critical for understanding the performance and durability of electronic devices. Solid-state NMR spectroscopy could be widely used for the analysis of various fluorine-containing materials for electronic devices. However, conventional CPMAS probes cannot be used for in-situ analysis of fluorine-containing electronic devices like LCD panels and Li-ion batteries. In this paper, we show the design, construction, and optimization of a $^{19}F-^{13}C$ double-resonance solid-state NMR probe for a 400MHz wide-bore magnet with a flat square coil for in-situ analysis of fluorine-containing electronic devices without observing fluorine background signals. This custom-built probe does not show any fluorine background signals, and can have higher efficiency for lossy samples.

Activation of Lysophosphatidic Acid Receptor Is Coupled to Enhancement of $Ca^{2+}$ -Activated Potassium Channel Currents

  • Choi, Sun-Hye;Lee, Byung-Hwan;Kim, Hyeon-Joong;Hwang, Sung-Hee;Lee, Sang-Mok;Nah, Seung-Yeol
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.3
    • /
    • pp.223-228
    • /
    • 2013
  • The calcium-activated $K^+$ ($BK_{Ca}$) channel is one of the potassium-selective ion channels that are present in the nervous and vascular systems. $Ca^{2+}$ is the main regulator of $BK_{Ca}$ channel activation. The $BK_{Ca}$ channel contains two high affinity $Ca^{2+}$ binding sites, namely, regulators of $K^+$ conductance, RCK1 and the $Ca^{2+}$ bowl. Lysophosphatidic acid (LPA, 1-radyl-2-hydroxy-sn-glycero-3-phosphate) is one of the neurolipids. LPA affects diverse cellular functions on many cell types through G protein-coupled LPA receptor subtypes. The activation of LPA receptors induces transient elevation of intracellular $Ca^{2+}$ levels through diverse G proteins such as $G{\alpha}_{q/11}$, $G{\alpha}_i$, $G{\alpha}_{12/13}$, and $G{\alpha}s$ and the related signal transduction pathway. In the present study, we examined LPA effects on $BK_{Ca}$ channel activity expressed in Xenopus oocytes, which are known to endogenously express the LPA receptor. Treatment with LPA induced a large outward current in a reversible and concentration-dependent manner. However, repeated treatment with LPA induced a rapid desensitization, and the LPA receptor antagonist Ki16425 blocked LPA action. LPA-mediated $BK_{Ca}$ channel activation was also attenuated by the PLC inhibitor U-73122, $IP_3$ inhibitor 2-APB, $Ca^{2+}$ chelator BAPTA, or PKC inhibitor calphostin. In addition, mutations in RCK1 and RCK2 also attenuated LPA-mediated $BK_{Ca}$ channel activation. The present study indicates that LPA-mediated activation of the $BK_{Ca}$ channel is achieved through the PLC, $IP_3$, $Ca^{2+}$, and PKC pathway and that LPA-mediated activation of the $BK_{Ca}$ channel could be one of the biological effects of LPA in the nervous and vascular systems.

Quantitative analysis of glycerol concentration in red wine using Fourier transform infrared spectroscopy and chemometrics analysis

  • Joshi, Rahul;Joshi, Ritu;Amanah, Hanim Zuhrotul;Faqeerzada, Mohammad Akbar;Jayapal, Praveen Kumar;Kim, Geonwoo;Baek, Insuck;Park, Eun-Sung;Masithoh, Rudiati Evi;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.2
    • /
    • pp.299-310
    • /
    • 2021
  • Glycerol is a non-volatile compound with no aromatic properties that contributes significantly to the quality of wine by providing sweetness and richness of taste. In addition, it is also the third most significant byproduct of alcoholic fermentation in terms of quantity after ethanol and carbon dioxide. In this study, Fourier transform infrared (FT-IR) spectroscopy was employed as a fast non-destructive method in conjugation with multivariate regression analysis to build a model for the quantitative analysis of glycerol concentration in wine samples. The samples were prepared by using three varieties of red wine samples (i.e., Shiraz, Merlot, and Barbaresco) that were adulterated with glycerol in concentration ranges from 0.1 to 15% (v·v-1), and subjected to analysis together with pure wine samples. A net analyte signal (NAS)-based methodology, called hybrid linear analysis in the literature (HLA/GO), was applied for predicting glycerol concentrations in the collected FT-IR spectral data. Calibration and validation sets were designed to evaluate the performance of the multivariate method. The obtained results exhibited a high coefficient of determination (R2) of 0.987 and a low root mean square error (RMSE) of 0.563% for the calibration set, and a R2 of 0.984 and a RMSE of 0.626% for the validation set. Further, the model was validated in terms of sensitivity, selectivity, and limits of detection and quantification, and the results confirmed that this model can be used in most applications, as well as for quality assurance.

A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL (하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템)

  • Jang, Byung-Jun;Park, Jae-Hyung;Yook, Jong-Gwan;Moon, Jun-Ho;Lee, Kyoung-Joung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1325-1332
    • /
    • 2009
  • In this paper, we design a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals with small size and improved noise performance using single circular-polarized antenna and phase-locked loop. The demonstrated bio-radar system consists of single circular-polarized antenna with $90^{\circ}$ hybrid, low-noise amplifier, power amplifier, voltage-controlled oscillator with phase-locked loop circuits, quadrature demodulator and analog circuits. To realize compact size, the printed annular ring stacked microstrip antenna is integrated on the transceiver circuits, so its dimension is just $40\times40mm^2$. Also, to improve signal-to-noise-ratio performance by phase noise due to transmitter leakage signal, the phase-locked loop circuit is used. The measured results show that the heart rate and respiration accuracy was found to be very high for the distance of 50 cm without the additional digital signal processing.

Development of Textile Fabrics Flexible Platform based Multiple Bio-Signal Central Monitoring System for Emergency Situational Awareness in High-Risk Working Environments (고위험 작업환경에서 응급상황 인지를 위한 직물형 플렉시블 플랫폼 기반의 다중 생체신호 중앙 모니터링 시스템 개발)

  • Jeon, Ki-Man;Ko, Kwang-Cheol;Lee, Hyun-Min;Kim, Young-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.227-237
    • /
    • 2014
  • The purpose of this paper is to implement a multiple bio-signal central monitoring system based on textile fabrics flexible platform which can obtain and monitor bio signals(heart rate, body temperature, electrocardiography, electromyogram) of workers in special working environments and additional situational information (3-axis acceleration, temperature, humidity, illumination, surrounding image). This system can prevent various accidents that may occur in the remote work environment and provide fast and efficient response by detecting workers' situations in real-time. For it, the textile fabrics flexible platform was made as innerwear or outerwear so that it does not interfere with workers' performance while collecting bio-signal and situational information, and obtained information is sent to the central monitoring system through wireless communication. The central monitoring system is based on wireless medical telemetry service of WMTS (Wireless Medical Telemetry Service); can monitor from 2 to 32 people simultaneously; and was designed so that it can be expanded. Also, in this study, to verify performance of the WMTS communication model, packet transmission rates were compared according to the distance.

A Study on Personalized Emotion Recognition in Forest Healing Space - Focus on Subjective Qualitative Analysis and Bio-signal Measurement - (산림 치유 공간에서의 개인 감정 인지 효과에 관한 연구)

  • Lee, Yang-Woo;Seo, Yong-Mo;Lee, Jung-Nyun;Whang, Min-Cheol
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.2
    • /
    • pp.57-65
    • /
    • 2019
  • This study is a scientific approach to psychological factors such as emotional stability among various effects of forest resources. In order to carry out this study, the experiment was conducted on the subjects by setting the forest healing space as various spaces. The subjects who participated in this experiment were the students in their twenties and the average age was 22±1.25 years. The subjects were assessed for emotional words through subjective sequence evaluation in different designated forest healing spot. In addition, the emotional states that they actually perceived were measured by measuring the bio-signals to their perceived emotions. BMP, SDNN, VLF, LF, HF, Amplitude, and PPI were used for the bio-signal reaction experiment applied to this study. The results of this experiment were measured by Friedman test and Wilcoxon test for statistical analysis. n this study, 'good', 'clear', and 'uncomfortable' words were found statistically significant at the spot of forest healing space for subjective emotional vocabulary. In addition, SDNN, HF and Amplitude were statistically significant in the results of quantitative bio-signal measurement at each spot in the forest healing space. Based on the results of this study, we can suggest the application direction and strategic utilization plan of forest healing spot and forest resource utilization field. This is not only a guide for the users who use the facility through the spatial facilities and physical requirements for the emotion based forest-healing, but also can be used as a personalized emotional space design aspect.

The implementation of Access Control System using Biometric System (Biometric System(fingerprint Reader)을 이용한 Access Control System 구현에 관한 연구)

  • 김광환;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.439-442
    • /
    • 2003
  • In this paper, a system that implementation of Access Control System Using Biometric System. Biometrics is science which deals with verifying or recognizing using physiological or behavioral characteristic Access Control System uses Biometric system to make an access control system. Biometrics goes under the study of bio-recognition or bio-measurement. It is a technology or study that identifies individuals using one's Biometric character. Access control system is a system used to identify one's entrance and exit, personal management, and security. Access control system can be joined with Biometric system to produce easier use and more sufficient effects. Access control system using Wiegand (Data Format) signal output, can replace earlier RF Card systems and make an access control (security) system. It uses RS-232, Rs-422 or TCP/IP type communication with the computer so an embedded system can be controlled using the software.

  • PDF

Measurement and Clinical Analysis of Carotid Intima, Media and Intima-Media Thickness

  • Kim, Wuon-Shik;Jeong, Hwan-Taek;Bae, Jang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.1
    • /
    • pp.6-13
    • /
    • 2005
  • Individual clinical significance of each layer of CCA (common carotid artery) has not been well studied. We intended to measure the intima thickness (IT), media thickness (MT), and intima-media thickness (IMT) of CCA separately and tried to analyze the clinical significance. One hundred fifty one consecutive patients (mean age: $57{\pm}15$ years; 77 males, 74 females) underwent CCA scanning using high-resolution ultrasound. The images were off-line analyzed using B-mode ultrasound image processing, devised for individual measurement of IT and MT as well as IMT. The mean coefficients of variation of new method measuring IT, MT, and IMT separately were 0.16% for IMT and 0.21% for both IT and MT. The IT (p < 0.01), MT (p < 0.01) as well as IMT (p < 0.001) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hypertension showed significantly thicker IT (p < 0.01), MT (p < 0.001), and IMT (p < 0.001) than that of the patients without hypertension. However, only IT was thicker in patients with smoking (p<0.01) than that of the patients without smoking.

  • PDF