• Title/Summary/Keyword: Bio signal

Search Result 668, Processing Time 0.032 seconds

Design of Compression Pants for Wireless sEMG Monitoring using e-textile (E-textile을 이용한 무선 sEMG 모니터링 컴프레션 바지 설계)

  • Heejae Jin;Hyojeong Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.1
    • /
    • pp.94-107
    • /
    • 2024
  • This study developed compression pants with excellent wearability and signal quality by approaching the design of wireless sEMG monitoring pants from the perspective of technical design, including the evaluation of wearability and the stable wireless transmission of signals through electrode and circuit design, and using e-textiles. An electrode, sewn with silver thread and a circuit stitched in a zigzag pattern using stainless steel wire, were applied. Additionally, polyurethane sealing tape was used to enhance adherence to the skin and reduce electrical resistance. Conductive snaps completed the design, allowing attachment and detachment to the bio-signal acquisition mainboard. Through the subjects' evaluation, it was determined that the final pants were applied with a pattern reduction rate of 25% to provide superior comfort according to different body parts while also minimizing skin irritation around the thigh circuit. The final pants for wireless sEMG monitoring, which demonstrated stable transmission of wireless measurements, was positively evaluated in terms of cognitive acceptability. This study is significant in that it achieved an optimal design by considering both technical aspects and the electrical characteristics of bio-signal monitoring garments, as well as the wearer's perception when designing smart wear.

근전도신호를 이용한 노약자/장애인용 재활 보조시스템의 인터페이스기법

  • 장영건;신철규;이은실;권장우;홍승홍
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.107-113
    • /
    • 1997
  • In this paper, an interfacing method to control rehabilitation assitance system with bio-signal is proposed. Controlling with EMG signals method has certain advantage on signal-collecting, but has some drawbacks in the function resolution of EMG signals because data-processing process is not efficient. To improve function-resolution and to increase the efficiency of EMG signal interfacing with rehabilitation assistance system, Multi-layer Perception which is highly effective with static signal and hidden-Markov model for dynamic signal resolving are fused together. In proposed method. The direction and average speed of the rehabilitation assitance system are controlled by the trajectory control and estimation of the moving direction result from the fused model. From the experiment, proposed GMM and 2-level MLP hybrid-classifier yielded 8.6% perception-error rate, improving function resolution. New acceleration control method constructed with 3 nested linear filter produced continuous acceleration paths without the information of destination point. Thus, the mass output caused by non- continuous acceleration-deceleration was eliminated. In the simulation, the necessary calculation, in the case of multiplication, was reduced by 11.54%.

  • PDF

Design of U-healthcare System based on Smart-Cloth (스마트 의류 기반의 유-헬스케어 시스템의 설계)

  • Cho, Byung-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.237-242
    • /
    • 2016
  • To build effective u-healthcare system based-on smart-cloth, design of hardware and software modules for suitable smart-cloth is needed. And a gateway smart-phone program for sensing signal's collecting and processing is needed to send sensing bio-signal from smart-cloth to sever. To do this, it is an important to design and describe modules well for having no difficult problems when implementing later. Also, if medical team do not monitor bio-signals sending from smart-phone frequently and these signals' change values which diagnose automatically due to building expert system based on rules/facts is informed for users, it will be an useful u-healthcare system. Therefore in this paper, by presenting design method of u-healthcare system hardware and software modules based on smart-cloth which prepared these functions, this design method is showed for applying a common use u-healthcare system's production usefully.

The Effects of Using a Pressure Bio-feedback Unit and a Pelvic Belt on Selective Muscle Activity in the Hip Abductor during Hip Abduction Exercise (엉덩 관절 벌림 운동 시 압력 생체 되먹임 장치와 골반 벨트의 사용이 엉덩 벌림근의 선택적 근 활성도에 미치는 영향)

  • Lee, Dong-Kyu;Moon, Se-Na;Noh, Kyung-Hee;Park, Kyung-Hee;Kim, Tae-Ho;Oh, Jae-Seop
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.323-330
    • /
    • 2011
  • Purpose : The purpose of this study was to examine the effects of using a pressure bio-feedback unit (PBFU) and a pelvic belt (PB) on the electromyographic (EMG) signal amplitude of the gluteus medius (Gmed) and the quadratus lumborum (QL) during hip abduction exercise when lying on the side. Methods : Twenty able-bodied volunteers (10 male, 10 female) were recruited for this study. The EMG signal amplitude was randomly measured during hip abduction with preferred hip abduction (PHA), with PBFU, and with PB. The surface EMG signal was recorded from the Gmed and the QL. Data were analyzed using a one-way repeated ANOVA. Results : Muscle activity of Gmed was significantly higher in PBFU and in PB than in PHA (p<.05). There were no significant difference between PBFU and PB(p>.05). Muscle activity of the QL was significantly lower in PB than in PHA(p<.05). The Gmed/QL muscle activity ratio was also significantly higher in PBFU and in PB than in PHA(p<.05), with no significant difference between PBFU and PB (p>.05). Conclusion : Based on these findings, using a PBFU and a PB is an effective method to disassociate QL use from Gmed use during hip abduction exercises when lying on the side.

A Tunable Band-Pass Filter for Multi Bio-Signal Detection (대역폭 조정 가능한 다중 생체 신호 처리용 대역 통과 필터 설계)

  • Jeong, Byeong-Ho;Lim, Shin-Il;Woo, Deok-Ha
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • This paper presents a tunable band pass filter (BPF) for multi bio-signal detection. The bandwidth can be controlled by the bias current of transconductance (gm), while conventional BPF exploited switchable capacitor array for band selection. With this design technique, the die area of proposed BPF reduced to at least one tenth the area of conventional design. The simulation results show the high cut-off frequency tuning range of from 100Hz to 1Khz. The circuit was implemented with a 0.18um CMOS standard technology. Total current consumption is 1uA at the supply voltage of 1V with sub-threshold design technique.

Influence of Atherosclerosis Risk Factors on Carotid Intima, Media, and Intima-Media thickness

  • Kim, Wuon-Shik;Bae, Jang-Ho;Jin, Seung-Hyun;Park, Yong-Ki;Noh, Gi-Yong;Hwang, Jae-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 2006
  • We intended to measure the IT, MT, and the IMT of carotid artery separately and tried to analyze the clinical significance. Two hundred and fifty consecutive patients (125 males, 125 females) underwent carotid artery scanning using high-resolution ultrasound. The images were off-line analyzed using B-mode ultrasound image processing, devised in our research. We measured the IT, MT, and IMT semi-automatically at the far wall of designated 1cm length of the right common carotid and calculated the average values over the 200 points. The IT (p < 0.05), MT (p < 0.05) as well as IMT (p < 0.01) of patients with atherosclerotic disease were significantly thicker than that of the patients without atherosclerotic disease. Patients with hypertension showed significantly thicker IT (p < 0.05), MT (p < 0.01), and IMT (p < 0.01) than that of the patients without hypertension. However, only IT was thicker in patients with smoking (p < 0.05) than that of the patients without smoking. Smoking was associated only with intima while hypertension was associated with the all three layer's thickness. This result suggests the atherosclerotic process can be different by cardiovascular risk factors.

  • PDF

A Study Concerning Analysis of Arousal State of locomotive Engineering During Operating Train (열차 운행 중인 기관사의 각성상태 분석에 관한 연구)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Lee, Jae-Ho;Lim, Min-Gyu;Baek, Jong-Hyen;Song, Yong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.891-898
    • /
    • 2012
  • The study for the passenger's comfortableness of vehicles and the arousal of car drivers has been done widely. On the other hand, there are few studies for the locomotive engineers. Human error means that the mistakes made by human, recently it receives attention in the field of safety engineering and human engineering. Comparing the operating condition of train with car, because of the simplification of the visual stimulus, the arousal level on the train goes down easily. The arousal level down makes judgement down, the accident risk from human error is getting bigger. In this study, we measured bio-signals(ECG, EDA, PPG, respiration and EEG) from 6 locomotive engineers to evaluate their arousal state while they operated the train. Also we recorded the 3 axes acceleration signal showing the vibration state of train. Also, the existence of tunnels were simultaneously measured. At the station section where the train speed goes down, the size of vector's sum decreases because of reduced vibration. Beta component in EEG tends to increase at the entering point of each station and tunnel. It is due to the arousal reaction and tension growth. The mean SCR(skin conductance response) was more increased in neutral section. As the button control movement (body movement) increases in the neutral section, it is appeared that SCR increase. RR interval tends to gradually increase during train operation for 1 hour 40 minutes. However, It tends to sharply decrease at the stop station because strong concentration needed to stop train on the exact point. The engineer's arousal reaction can be checked through analysing the bio-signal change during train operation. Therefore, if this analysing result is adopted to the sleepiness prevention caution system, it will be useful for the safety train operation.

Implementation of RFID based on the self-blood sugar measurement system (RFID기반의 자가 혈당측정 시스템의 구현)

  • Park, Tae-Jin;Lee, Jong-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.10
    • /
    • pp.2079-2086
    • /
    • 2011
  • Recently, technology of self diagnosis system which one of health-care has been research very active. With this, In this paper, we have to implement the self-blood sugar measurement system that is interlock with PC, RFID, and Bio-Signal glucose tester and accessible user interface. Therefore the equipments can performs accessible interface composition for communication between devices and PC, analysis and test of communication status of the RFID tag and reader that it easy to obtain the data of self-diagnosis linkage with PC, RFID, and Bio-Signal glucose tester. In other words, as result of communication protocol experiment with self-blood sugar measurement data, it has been showed to display a high-reliability result through year, month, and day, body temperature, and levels and check point of blood glucose.

Design of Digital-clothing that can Detect Driver's Bio-signal and Position (운전자의 생체신호 및 위치 파악이 가능한 디지털 의류 설계)

  • Lee, Min-hye;Jeong, Dong-myong;Shin, Seong-yoon;Jeon, Tae-il;Choi, Jae-seok;Jeong, Gi-soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.171-173
    • /
    • 2018
  • The poor working conditions of transit drivers not only lead to mental stress and fatigue accumulation of workers, but also to the main causes of mass transit accidents. Stress and fatigue accumulation are closely related to the vital signs because they affect the psychological and physical health. In this paper, we designed a digital garment which can measure driver's health condition by measuring electrocardiogram, pulse rate and body temperature. Also proposed a system that transmits the measured bio-signal to the smartphone app via Bluetooth and transmits the current position of the driver to the server by using the built-in GPS of the smartphone, assuming there is something wrong.

  • PDF