• Title/Summary/Keyword: Bicon implant

Search Result 13, Processing Time 0.02 seconds

THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES (임플란트 표면에 따른 인공치면세균막 형성에 관한 연구)

  • Kim, Jin-Woo;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS WITH INTERNAL CONNECTION BETWEEN THE IMPLANT AND THE ABUTMENT (임플란트와 지대주간 내측 연결을 갖는 임플란트 보철의 유한요소 응력분석)

  • Ahn, Jong-Kwan;Kay, Kee-Sung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.356-372
    • /
    • 2004
  • Statement of problom: In the internal connection system the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. Purpose: The purpose of this study was to assess the loading distributing characteristics of 3 implant systems with internal connection under vertical and inclined loading using finite element analysis. Material and method: Three finite element models were designed according to the type of internal connection of ITI(model 1), Friadent(model 2), and Bicon(model 3) respectively. This study simulated loads of 200N in a vertical direction (A), a $15^{\circ}$ inward inclined direction (B), and a $30^{\circ}$ outward inclined direction (C). Result: The following results have been made based on this numeric simulations. 1. The greatest stress showed in the loading condition C of the inclined load with outside point from the centric cusp tip. 2. Without regard to the loading condition, the magnitudes of the stresses taken at the supporting bone, the implant fixture, and the abutment were greater in the order of model 2, model 1, and model 3. 3. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture, and lower stress was taken at the cancellous bone. 4. The stress of the implant fixture was usually widely distributed along the inner surface of the implant fixture contacting the abutment post. 5. The stress distribution pattern of the abutment showed that the great stress was usually concentrated at the neck of the abutment and the abutment post, and the stress was also distributed toward the lower part of the abutment post in case of the loading condition B, C of the inclined load. 6. In case of the loading condition B, C of the inclined load, the maximum von Misess stress at the whole was taken at the implant fixture both in the model 1 and model 2, and at the abutment in the model 3. 7. The stress was inclined to be distributed from abutment post to fixture in case of the internal connection system. Conclusion: The internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, and the abutment according to the abutment connection form had differenence among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the a butment post.

COMPARATIVE STUDY OF OSSEOINTEGRATION OF 4 DIFFERENT SURFACED IMPLANTS IN THE TIBIA OF DOGS (성견 경골에서 표면처리방법이 다른 4종의 임프란트 골유착에 관한 비교연구)

  • Hong, Who-Suk;Kim, Tae-Hee;Ryu, Seong-Hee;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.46-54
    • /
    • 2005
  • Purpose: This study was performed in order to compare the osseointegration of 4 different surfaced implants in the dog's tibia which has thick dense cortical bone and loose marrow space. Materials & methods: Four mongrel dogs and four different surface types of implants, smooth surfaced AVANA implants, RBM surfaced AVANA implants, HA-coated Steri-Oss implants and SLA Bicon implants, were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics: Control group, RBM group, HA group, and SLA group. Three implants of each group were installed into the metaphysis of tibia of adult dogs. The animals were sacrificed at 8 weeks after implantation. The undecalcified specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: Radiographically and histologically good osseointegration of implant was observed in the dense cortical bone, but poor osseointegration was observed in the marrow space. Histologically more bone apposition to implant surface was found in rough surfaced groups than the smooth surfaced, Control group. In histomorphometric findings of cortical bone the average bone-implant contact ratios of HA group (95.4%, p<0.01), RBM group (87.1%, p<0.05), and SLA group (86.0%, p<0.05) were significantly higher than that of Control group (75.9%). In marrow space the average bone-implant contact ratios of HA group (76.1%, p<0.01) and SLA group (45.4%, p<0.05) were significantly higher than that of Control group (29.6%). The ratio of RBM group was higher than that of Control group but there was no significantly difference between RBM group and Control group. Conclusion: These results suggest that the rough surfaced implants can obtain the better osseointegration than the smooth surfaced implant in the cortical and marrow space and that HA-coated implants can obtain the best osseointegration in the marrow space among them.