• Title/Summary/Keyword: Bi-2223 superconducting tape

Search Result 131, Processing Time 0.022 seconds

The effect of pre-treatment on superconducting property and deformation of Bi-2223/Ag tapes. (Bi-2223/Ag 고온초전도 선재의 전처리에 따른 가공성 및 초전도 특성)

  • Ha, Hong-Soo;Lee, Dong-Hoon;Choi, Jung-Kyu;Hwang, Sun-Yuk;Yang, Joo-Saeng;Kim, Sang-Chul;Ha, Dong-Woo;Oh, Sang-Soo;Kwon, Young-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.25-29
    • /
    • 2003
  • Pre-treatment of Bi-2223/Ag tapes has been investigated to improve the superconducting property and grain alignment. However, rolling deformability of Bi-2223/Ag wires was degraded by the breakage of Ag alloy sheath after pre-treatment. Various pre-treatment conditions were tried to prevent the problem of sliver sheath and improve the superconducting property of Bi-2223/Ag tapes. Filament precursor of Bi-2223/Ag tapes was modified to be textured easily during main sintering by the optimum pre-treatment with low oxygen pressure and up to $800^{\circ}C$. Critical current was also increased up to 20% than that of no pre-treated tape.

  • PDF

A Study of Joining Method of BSCCO(2223) Tape (BSCCO(2223) 초전도 선재의 접합공정 연구)

  • 김정호;김중석;김태우;지붕기;주진호;나완수
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.1-7
    • /
    • 1999
  • we evaluated the effects of joining process such as contact method. shape of joined area and pressure on the electrical and mechanical properties of Bi-2223 superconducting tape, Specifically. the current capacity of the jointed tape was measured as a function of uniaxial pressure. and the thermal shock, bonding strength and the thermal of the tape were evaluated and correlated to the microstructural evolution. It was observed that the current capacity was significanrly dependent on the uniaxial pressure The jointed tape, fabricated with a pressure of 1,000-1,600 Mpa. showed the highest value of current capacity results from improvements in core density, contacting area and grain alignment, ect. In addition, the strength of jointed tape was measured to be 86 Mpa, which is about 88% of the unjoined ape's strength. The irreversible strain($\varepsilon$irrev) for the jointed tape was measured to be 0.1%, smaller than that of unjoined tape ($\varepsilon$irrev= 0.3%). The decrease in the strength and irreversible strain for jointed tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

The Electrical.Mechanical Properties df Ag Sheathed Bi2223 High-$T_c$ Superconducting Wire (Ag 피복 Bi2223 고온초전도 선재의 전기적.기계적 특성)

  • Jang, H.M.;Oh, S.S.;Ha, D.W.;Ha, H.S.;Ryu, K.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1339-1341
    • /
    • 1997
  • The various type Ag sheathed Bi-2223 tapes have been were fabricated by Powder-in-tube(PIT) process. The critical current density could be improved with the value of $23,000\;A/cm^2$(77 K, zero field) in the single concentric Bi-2223 tape. The bending property dependence of $I_c$ was improved in the double concentric Bi-2223 tape compared with single filamentary and single concentric one.

  • PDF

Analysis of the Operational Characteristics of High-Tc Superconducting Power Supply Using by BSCCO Tape (BSCCO 고온초전도선재를 이용한 고온초전도전원장치의 동작특성 해석)

  • Ahn, Min-Cheol;Kim, Ho-Min;Yoon, Yong-Soo;Ko, Tae-Kuk;Lee, Sang-Jin;Han, Tae-Su
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.12-14
    • /
    • 2001
  • This paper deals with the fabrication and characteristic experiment of a high-Tc superconducting (HTSC) power supply using by Hi-2223 tape. The purpose of this research is to apply real HTSC load. This system consists of two heaters, an electromagnet, a Bi-2223 solenoid and a Bi-2223 pancake load. In the experiment, 17sec and 8.5sec were used for pumping period. Mechanism of the superconducting switch is used for heater-trigger. In experiment, the pumping-current has reached about 1.2A.

  • PDF

Development and fabrication of multi-filamentary Bi(2223)/Ag jointed tape (Bi(2223)/Ag 다심 초전도 접합선재의 제조)

  • 김규태;김정호;김호진;이동욱;주진호;나완수
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.172-175
    • /
    • 2003
  • Critical current ratio and n-value of Bi(2223)/Ag superconducting joint tape were measured as a function of uniaxial pressure. In the superconducting joint method, MM and MSM joint were used ; MM joint is direct connection of two -multi filamentary tapes, and MSM is connection of them by using a single -filamentary tape. It was observed that the critical current ratio(CCR) for jointed tapes was not dependent on the uniaxial pressure but joining methods. The n-value of jointed tapes has similar trends with that of the CCR. Especially, double MSM joint showed the highest electrical properties as 63.4-76.0%(CCR) and 3.5-5.1 (n-value). It is considered that the improvements are due to the better inter connections of multifilaments by two single filamentary tapes on both sides.

  • PDF

Transport current loss of YBCO Coated Conductor and Bi-2223 tape (Bi-2223 선재와 YBCO Coated Conductor 선재의 전송전류 손실 비교)

  • Lim Hyoungwoo;Lee Kwangyoun;Cha Gueesoo;Lee Jikwang;Park Chan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1010-1012
    • /
    • 2004
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper we measured and compared characteristics of BSCCO tape and YBCO Coated Conductor(YBCO CC). BSCCO tape was fabricated by PIT method. We measured critical current density and transport current loss of it. Also, YBCO CC tape consist of substrate. buffer, YBCO and metal layers. We measured critical current density on variations of external magnetic field and transport current loss of these cases. The results of measurement show that normalized critical current of YBCO CC is smaller then that of BSCCO tape in the external magnet field. According to the results. measured loss and calculated of the YBCO CC show the same tendency.

  • PDF

The characterization of Bi-2223/Ag tape fabricated by using the rectangular dies (사각 다이스를 이용한 Bi-2223/Ag 선재의 특성평가)

  • 정재훈;유재무;고재웅;김영국;신평우
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.168-171
    • /
    • 2003
  • It was known that properties of superconducting tapes could be influenced by mechanical processing method. In this presentation, the effect of drawing method on the final properties of superconductor tape has been systematically studied. Firstly, BSCCO/Ag tapes have been fabricated via two-stage drawing method and conventional rolling process. The two-stage drawing process consists of circular dies drawing and rectangular dies drawing. Important parameters such as fill factor and critical current values of fully processed superconducting tapes have been evaluated to elucidate the effect of drawing method.

  • PDF

A study on the safe operation condition for Bi-2223/Ag tapes with applied alternating currents (교류용 Bi-2223/Ag 선재의 안정 통전 조건에 관한 연구)

  • Yim S. W.;Sohn S. H.;Hwang S. D.;Lim S. H.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.138-141
    • /
    • 2005
  • Bi-2223/Ag tapes need to be safe, even it is under the over-critical current state for the protection of a superconducting power machine. However, it is not easy to identify the condition for the safe operation because of their broad S/N transition region. In this paper, for the study of the operation condition of Bi-2223/ Ag tapes, we investigated the V-I curves and the temperature variation of Bi-2223/ Ag tapes experimentally, applying alternating over-currents, and analyzed the relationship between resistance and temperature increase. For the experiments, a Bi-2223/Ag tape of 57 A $I_c$ was prepared, and the over-critical current characteristics under adiabatic state from $LN_2$ was measured. From the experiments, we confirmed that the Joule heating predicted by V-I curve corresponded with the increase of the measured temperature exactly. Using the results, a safe operation condition of Bi-2223 tape was discussed.

  • PDF

Degradation Behavior of Critical Current in Bi-2223 Superconducting Tape in Bending-Tension Mixed Mode (인장-굽힘모드에서 Bi-2223 초전도 테이프의 임계전류 열화거동)

  • Shin, Hyung-Seop;Kim, Byung-Soo;Choi, Ho-Yeon;Oh, Sang-Soo;Ha, Dong-Woo;Ha, Hong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.573-576
    • /
    • 2003
  • HTS superconducting tapes are now commercially available for practical applications such as magnets and cables. Since superconductors in such applications are subjected to high mechanical loads that can significantly degrade the superconducting properties, mechanical properties and the strain tolerance known as the strain effect on superconducting properties are needed to be estimated for developing superconducting devices. Influences of loading mode on the Ic degradation and the interaction on strain effect were discussed in this study.

  • PDF

Effect of Field Orientation on Magnetization Loss in a Stacked Bi-2223 Conductor (자장방향이 적층 Bi-2223도체의 자화손실에 미치는 영향)

  • 류경우;김현준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2003
  • The ac loss is an important issue in the design of high-Tc superconducting power devices such as transformers and cables. In these devices many Bi-2223 tapes are closely stacked together and exposed to alternating magnetic fields that can have different orientations with respect to a tape. In such arrangement the magnetization loss is influenced by the screening current induced in adjacent tapes and thus different from that in a single tape. This stacking effect was experimentally investigated by measuring the magnetization loss in a stack, which consists of a number of tapes. First the magnetization loss in the single tape was measured in order to confirm the reliability of the loss data measured in the stack. The results for the single tape coincide well will the loss characteristics described in other previous works. For the stack In parallel and longitudinal magnetic fields the measured loss is Independent of both the number of tapes and stacking type. The longitudinal magnetization loss Is well explained rather by the slab model for decoupled filaments. For the tall stack in perpendicular field the measured loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is unaffected. These loss behaviors in the tall stack are well described by the slab model for full coupling.