• 제목/요약/키워드: Bi-2223 HTS tape

검색결과 85건 처리시간 0.024초

고온 초전 도체의 산화물 코팅 조건 변화에 따른 초전도 특성의 변화 (Superconducting properties through ceramic coating condition on high-Tc superconducting tapes)

  • 이남진;하동우;하홍수;장현만;오상수;손명환;권영길;김상현;류강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.218-221
    • /
    • 2000
  • Currently, Bi-2223 HTS tape is capable of being fabricated in longer than 100m length by industrial processes. But there are some problems in heat treatment of the degree of longer than 100m tape, which is in term of volume occupied with specimen in furnace. The effects of ceramic coating with variable slurry states were studied in Bi-2223 high-temperature superconductor. The HTS tapes coated with oxide were prepared by using dip-coating method on slurry state. Critical current(I$_{c}$) of tapes coated with ceramic materials were equal with 11.5A at 77K after first heat treatment as different slurries. For final heat treatment, Critical current of HTS tapes coated with zirconia oxide mixed in PMMA and PVA organic solute were 20.8A at 77K. The breakdown voltage of HTS tapes coated with zirconia oxide were 3kV in air and 4~7kV in L$N_2$.>.

  • PDF

Prototype 고온초전도 케이블의 최소 Quench에너지 및 대전류 특성 (A Characteristics of Large Current and Minimum Quench Energy on Prototype High-$T_c$ Superconducting Cable)

  • 김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.236-242
    • /
    • 2000
  • NZP velocities were investigated on Ag sheathed multi filamentary Bi-2223 tape and direction type HTS cable. The critical current($I_c$) of Ag sheathed Bi-2223 tape and direction type HTS cable were 12 A, 63 A at 77 K, 0 T. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. In case of DC, the NZP velocities of numerical analysis and experiment were almost same. NZP velocities of direction type HTS cable were 1.9-2.4 cm/sec. The result shows that the total transport current of spiral type HTS cable in $LN_2$ was 475[A], and transport current passed through almost the outer layer (2-layer). Also, AC transport losses in outer layer of HTS cable was proportion to $I^2$ and higher than losses of inner layer. And in case of $I_p=I_c$, calculated numerical loss density was concentrated on the edge of tape and most of loss density in cable was distributed outer layer more than inner layer.

  • PDF

Critical Current Degradation Analysis in HTS Pancake Coil due to Self Field Effects

  • Nah, Wan-Soo;Joo, Jin-Ho;Yoo, Jai-Moo
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.68-72
    • /
    • 1999
  • Since the discovery of high Tc superconductors, great efforts have been focused to develop high performance HTS magnets for the ultimate applications to power system devices. Magnet designers, however, have had difficulties in the estimation of the maximum operating current of the designed magnet from the tested short sample data, due to the degradation of the critical current density in the magnet. Similar story applies to the HTS electrical bus bar. It has been found that the critical current of Bi-2223 stacked tapes is much less than the total summation of critical currents of each tape, which is mainly attributed to the self magnetic fields. Furthermore, since the critical current degradation of Bi-2223 tape is greater in the normal magnetic field (to the tape surface) than in the parallel one, detailed magnetic field configurations are required to reduce the self field effects. In this paper, we calculate the self field effects of a stacked conductor, defining self field factors of normal and parallel magnetic fields to the tape surface. Finally, the critical current degradations in the HTS magnet are explained by the introduced self field factors of the stacked conductor.

  • PDF

고온 초전도체 테이프의 상전도 영역 전파 특성 해석 (Analysis of normal Bone propagation characteristics in a high-temperature superconducting tape)

  • 정신근;설승윤
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.11-15
    • /
    • 2001
  • Stability of a Bi-2223/Ag tape was studied by using a numerical model considering the temperature distribution of cross-sectional area. The dynamic evolution of normal zone of a HTS tape can be shown by the developed two-dimensional Program using finite difference method. Two kinds of analyses are compared to quantify the critical disturbance energy for quenching HTS tapes. One is the length-thickness(x-r) side and the other is the length-width(x-z) side. For each case. the governing energy balance equations and corresponding boundary conditions are formulated. The results of analyses shows that the critical disturbance energies for each cases seem to be very close for considered Bi-2223/Ag tape .

  • PDF

굽힘상태의 외부보강한 Bi-2223 초전도테이프에서 임계전류 열화특성에 미치는 인장변형률의 영향 (Effect of Tensile Strain on $I_c$ Degradation Characteristics In Bent Externally Reinforced Bi-2223 Superconducting Tapes)

  • 신형섭;김기현;오상수;하동우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.6-11
    • /
    • 2004
  • The influences of mixed strain mode of bending-tension on the critical current. Ic in externally reinforced Bi-2223 tapes and their interaction were investigated in this study. A test fixture which providing a mixed deformation mode of bending-tension to HTS tapes has been newly devised. When the total strain induced in the tape in the mixed strain mode was expressed by the superposition of the bending and tensile strains the irreversible strain for the critical current degradation of Bi-2223 tapes increased, as compared with the simple bending mode case. The $I_c$ degradation at the region exceeding the irreversible strain showed a medium between the simple bending case and the simple tension case. As the initial bending strain imparted increased , namely as the diameter of mandrel adopted decreased. the apparent irreversible strain in Bi-2223 tapes increased . but the increment became smaller As a result. it can be found that the tension to be applied to bent Bi-2223 tapes during cabling should be smaller. as the mandrel diameter becomes smaller.

단층원통형 고온초전도도체의 교류손실 특성 (AC Loss Characteristics of a Single-layered Cylindrical High Temperature Superconductor)

  • 마용호;이주영;류경우;손송호;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.626-630
    • /
    • 2007
  • The AC loss is an important issue in the design of the high temperature superconductor (HTS) power cables and fault current limiters. In these applications, a cylindrical HTS conductor is often used. In commercialization of these apparatuses, AC loss is a critical factor but not elucidated completely because of complexities in its measurement, e.g. non-uniform current distribution and phase difference between currents flowing in an individual HTS tape. We have prepared two cylindrical conductors composed of a Bi-2223 tape with different critical current density. In this paper, the AC loss characteristics of the conductors have been experimentally investigated and numerically analyzed. The result show that the measured losses for two conductors are not dependent on both arrangements and contact positions of a voltage lead. This implies that most of loss flux is only in the conductors. The loss for the Bi-2223 conductor with low critical current density is in good agreement with the calculated loss from Monoblock model, whereas the loss measured for the Bi-2223 conductor with high critical current density doesn't coincide with the loss calculated from the Monoblock model. The measured loss is also different from numerically calculated one based on the polygon model especially in low transport current.

은 피복 Bi-2223 고온초전도 선재의 안정성 (Stability of Ag Sheathed Bi-2223 HTS Tape)

  • 장현만;오상수;하홍수;하동우;정종만;류강식;김상현
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.369-372
    • /
    • 1999
  • Using Ag sheathed multi filamentary Bi-2223 tape, stability against heat pulse has been investigated. The measured normal zone propagation(NZP) velocity of the tape was found to be faster due to increase of operating current and magnetic field, and agree well with calculated data from one dimensional heat balance equation. Minimum quench energy(MQE) was found to be larger than 17 J at 30 K zero magnetic filed at operating current of 96.5 with respect to I$_c$.

  • PDF

고온초전도 케이블용 은시스 Bi-2223 테이프 및 적층 도체의 안정성연구 (A Study on Stability of Ag sheathed Bi-2229 tape and Cylindrical Stacking Conductor for HTS Cable)

  • 이병성;김영석;장현만;백승명;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1554-1556
    • /
    • 2000
  • Normal zone propagation(NZP) characteristics were investigated on Ag sheathed multi filamentary Bi-2223 tape and cylindrical stacking conductor. The critical current($I_c$) of Ag sheathed Bi-2223 tape and cylindrical stacking conductor were 12 A, 63 A at 77 K, 0 T. Normal zone propagation(NZP) experiments with tape were conducted with refrigerator in temperature from 45 K to 77 K, 0 T. Cylindrical stacking conductor was molding with epoxy and experiments were conducted with adiabatic condition in $LN_2$. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. Temperature ($T_1$) of tape with distance of 0.5 cm from heater was strongly climbed up to 95K and slowly decreased. NZP velocities of cylindrical stacking conductor were 1.9-2.4 cm/sec in $LN_2$.

  • PDF

고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구 (Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system)

  • 김동혁;고락길;강부민;하동우;손명환;문치웅
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권1호
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.