• Title/Summary/Keyword: Bending Method

Search Result 2,709, Processing Time 0.039 seconds

A Study on the Lateral Pressure Effect under Axial Compressive Load of Ship Platings (종방향 압축력을 받는 선체판부재의 횡압력 영향에 관한 연구)

  • Park, Joo-Shin;Ko, Jae-Yong;Lee, Jun-Kyo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.61-67
    • /
    • 2005
  • The ship plating is generally subjected to combined in-plane load and lateral pressure loads. In-plane loads include axial load and edge shear, which are mainly induced by overall hull ginder bending and torsion of the vessel. Lateral pressure is due to water pressure and cargo. These load components are not always applied simultaneously, but more than one can normally exist and interact. Hence, for more rational and safe design of ship structures, it is of crucial importance to better understand the interaction relationship of the buckling and ultimate strength for ship plating under combined loads. Actual ship plates are subjected to relatively small water pressure except for the impact load due to slamming and panting etc. The present paper describes an accurate and fast procedure for analyzing the elastic-plastic large deflection behavior up to the ultimate limit state of ship plates under combined loads. In this paper, the ultimate strength characteristics of plates under axial compressive loads and lateral pressure loads are inverstigated through ANSYS elastic-plastic large deflection finite element analysis with varying lateral pressure load level.

  • PDF

Evaluation of Fatigue Degradation in SUS316L Using Nonlinear Ultrasonics (초음파의 비선형 특성을 이용한 SUS316L 재료의 피로 열화 평가에 관한 연구)

  • Choi, Ik-Hwang;Baek, Seung-Hyun;Lee, Tae-Hun;Jhang, Kyung-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • This study evaluated the fatigue degradation in a SUS316L specimen using the nonlinear ultrasonic method. The nonlinearity of the ultrasonic wave was estimated by a relative nonlinear parameter defined as the ratio of the amplitudes for the fundamental wave to the second harmonic wave. In the experiment, a measurement system with contact transducers was constructed; reliable measurements were assured by keeping measurement conditions consistent and reducing extra harmonics generated in the measurement system. Two types of SUS316L specimen were used in experiments; a rotating bar fatigue specimen and a tensile fatigue specimen. The fatigue condition used was high cycle fatigue. The former specimen had a cylindrical shape and was used to observe the change in the nonlinear parameter after fatigue accumulation in a specimen. The latter was a plate-shaped specimen and was used to confirm the change in the nonlinear parameter at the position where the fatigue stress was concentrated. The measured nonlinear parameter showed a strong correlation to the damage level in both fatigue tests.

Development of a Closed Roof Model for Liquid Manure Storage Tanks to Prevent Corrosion and Atmospheric Diffusion of Oder Gases (부식과 악취가스 대기확산 방지를 위한 액비저장조 밀폐형 지붕모델 개발)

  • Yun, N.K.;Lee, S.H.;Kim, K.W.;Yum, S.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • The roof structural model of liquid manure storage tank was designed to improve a structural safety and an ability of resistance to corrosion by the bad environmental condition with high humidity and high gas concentration. Due to corrosion of a general steel, the 5 years used materials were reduced to one-third of a new material in the result of a bending strength test. Some structural materials were tested to evaluate a strength and an anti-corrosion, and stainless steel pipe (STS439), steel angle with zinc hot dipping, rectangular steel pipe covered with FRP (Fiberglass Reinforced Plastics) resin were selected finally. A stainless steel is more expansive about $3{\sim}5$ times than general structural steel. But its durability under heavy corrosive environment is expected twice as long as general steel. The roof models were designed as closed cone type for each of the three structural materials. In the result of a FEM (Finite Element Method) structural analysis for the developed models, the safe snow depth was higher 2.3 times than a general roof structure, when elements of equal section modulus were used.

  • PDF

Far-Infrared Emission Characteristics of Germanium Included Fabrics for Emotional Garment (게르마늄 함유 감성의류용 직물의 원적외선 방출 특성)

  • Kim, Hyun-Ah;Kim, Seung-Jin
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.687-692
    • /
    • 2010
  • This paper surveys emission characteristics of Far-infrared of the fabrics fabricated with germanium imbedded sheath-core conjugate composite filaments. For this purpose, master batch chip was prepared with PET semi-dull chip and nano sized germanium particles and sheath-core type conjugate composite filament was spun using this master batch chip and polyester semi dull. The emission power and emissivity of the germanium imbedded fabrics were measured and investigated using FT-IR spectrophotometer by KICM- FIR 1005 measurement method. In addition, the fabric mechanical properties were measured and discussed with the effects of the optimum texturing process conditions and fabric structural design conditions. The sheath/core type PET composite germanium imbedded filaments were manufactured by the optimum spinning condition, its tenacity and breaking strain showed the same level as the regular PET filament. The tenacity and breaking strain of the DTY showed good physical properties and no problem in the weaving process. Then, wet and dry shrinkages showed higher values than those of regular PET filament. The emission power of the germanium imbedded fabric was $3.53{\times}10^2W/m^2$ at the $5-20{\mu}m$ wave length range, and emissivity was 0.874. The fabric hand of germanium imbedded fabrics was inhanced by the optimum texturing process and fabric structural design with improved mechanical properties such as fabric bending and compressional properties.

  • PDF

A Study on the Estimation for the Compressive Strength of Member According to the Knot Types (옹이 형태별 소재의 압축강도 예측에 관한 연구)

  • Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.170-177
    • /
    • 2010
  • Finite element numerical analysis was conducted with using the knot data which has a strong influence on the prediction of capacity for the structural wood member. Wood is a orthotropic property unlike other structural materials, so orthotropic property was applied. Knot was modelled as a cylinder shape, cone shape, and cubic shape. Compressive test was carried out to investigate the failure types and to calculate ultimate strengths for the wood members. Numerical model which can reflect the member size, number of knot, location of knot, size of knot was created and analyzed. By the numerical analysis using the ultimate compressive strength, numerical stress distribution types of each specimen was compared to real failure types for the test specimen. Cylinder shape modelling might be most reasonable, according to the necessary time for the analysis, the difficulty of element meshing, and the similarity of stress transfer around knot. Moreover, according to the stress and deformation distribution for the numerical analysis, failures or cracks of real specimen were developed in the vicinity of stress concentrated section and most transformed section. Based on the those results, numerical analysis could be utilized as a useful method to analyze the performance of bending member and tensile member, if only orthotropic property and knot modelling were properly applied.

COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN (4종의 간접법용 복합 레진의 기계적 특성 비교)

  • Kim, Kil-Soo;Yoon, Tae-Ho;Song, Kwang-Yeob;Ahn, Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

CLINICAL CONSIDERATION ON USING THE ELASTIC 'TIE BACKS' DURING SPACE CLOSURE ('Elastic tie back'을 이용한 발치공간 폐쇄에 관한 임상적 고려)

  • Cho, Ki-Soo;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.217-227
    • /
    • 1993
  • Preadjusted appliance, following the original concept of the Andrews Straight-Wire appliance, became increasingly common in the 1980s. In six phases of treatment, anchorage control, leveling and aligning, overbite control, overjet reduction, space closure, and finishing are very effective with using the preadjusted appliances. Space closure is the phase of treatment in which the difference between standard edgewise and preadjusted mechanics is most noticeable. Orthodontists have been able to reduce the use of closing loops and, because of the level slot lineup, enjoy the advantages of sliding mechanics. In 1990, Dr. John C. Bennett and Richard P. McLaughlin introduced the new space closure system, namely, elastic 'tiebacks'. They found an $.019'\times.025'$ working archwire most effective in an .022'-slot system. Hooks of .024' stainless steel or .028' brass wire are soldered to the upper and lower archwires. The force required for space closure is delivered by elastic 'tiebacks'. An elastic modulo stretched by 2-3mm(to twice its normal length) usually delivers 0.5-1.5mm of space closure per month. Group movement and sliding mechanics are combined for gentle, controlled space closure, so that about 0.5mm of incisor retraction and 0.5mm of mesial molar movement can be seen each month. The tiebacks are replaced every four to six weeks. By using the elastic 'tiebacks', the next two cases were treated during space closure. Even though we found some clinical problems of this mechanics, long treatment time, hard to control of vertical dimension and anchorage, the application method of this system is so simple that orthodontists can manage many patients during short chair time. But we must apply this mechanics after perfect understanding of the biomechanics in tooth movement.

  • PDF

Analytical and Experimental Study on the Quality Stability of Multi Roll Forming Process (멀티 롤 포밍 공정의 품질 안정성에 대한 해석 및 실험적 연구)

  • Son, Jae-Hwan;Han, Chang-Woo;Ryu, Kyung-Jin;Kang, Hae-Dong;Kim, Chul-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6977-6984
    • /
    • 2015
  • It is faced with the necessity of multi roll forming process of the ball slide rail which is made by adding the separate manufacturing processes, piercing, bending, trimming, to the roll forming process of a continuous plastic deformation, to improve the quality. However, the vibration and noise of the press machine in this process leads to the quality degradation of slide rail manufactured in this process. In this study, the roll was designed considering the optimal strain rates by the roll forming program with finite element method. And to estimate the static stability of the multi process the Von-Mises stress and deformation on the press was calculated with a structural analysis program. Also, to avoid driving systems in the resonance region their natural frequencies in the 1st and 2nd mode were calculated through the modal analysis. To verify its dynamic stability improvement the magnitudes of noise and vibration in the existing and studied system were compared using a microphone and accelerometers. And the widths and surface roughnesses of the rails which had been produced in the existing and studied process were measured. Therefore, it is known that multi roll forming process is stable in the analytical and experimental study.

Correlation Analysis Between Lumbar Scoliosis of X-ray and HIVD of L-spine MRI in LBP Patients who Visit Korean Medicine Hospital (한방병원에 요통으로 내원한 환자에서 X-ray상 요추측만과 MRI상 HIVD와의 연관성 분석)

  • Kim, Kil-Hwan;Choi, Young-Jun;Kwon, Ok-Jun;Joo, Young-Kuk;Song, Seung-Bae;Song, Gwang-Chan;Seo, Ji-Yeon;Choo, Won-Jung
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.11 no.1
    • /
    • pp.41-51
    • /
    • 2016
  • Objectives : This study is planned to classify Correlation between Cobbs Angle of Lumbar scoliosis and prevalence of Lumbar Intervertebral Disc. Methods : We Measured the lumbar scoliosis angle of the 114men and 91 women patients with lumbar pain in Bucheon Jaseng Korean Medicine Hospital. We use Cobb's angle method for measuring the lumbar scoliosis. And We use Magentic Resonance Imaging(MRI) for classifying the patient who has lumbar intervertebral disc or not. Results : 1.There was no statistical relation between the Cobbs angle and gender(P>0.05) 2.There was no statistical relation between the Cobbs angle and age(P>0.05) 3.There was significant relation between the direction of lumbar scoliosis and the direction of disc herniation(P<0.05) 4.There was no statistical relation between on the Cobbs angle and disc herniation. The more severe of lumbar scoliosis has not tendency of disc herniation. 5.There was no statistical relation between lumbar scoliosis Cobbs Angle on HIVD of L-spine patient and direction of disc herniation on horizontal plane. Conclusions : The direction of disc herniation has tendency of the opposite direction of lumbar scoliosis. When disc herniation, opposite side bending broad intervertebral foramen and reduce pressure.

  • PDF

A FINITE ELEMENT ANALYSIS ON STRESS AND DISPLACEMENT ACCORDING TO ISTHMUS WIDTH OF GOLD INLAY CAVITY (금인레이 와동의 폭경에 따른 응력분포와 변위에 관한 유한요소법적 연구)

  • Shin, Gang-Suk;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.395-411
    • /
    • 1993
  • The purpose of this study was to examine the clear concept of the designs for cavity preparations. Among the several parameters in cavity designs, profound understanding of isthmus width factor would facilitate selection of the appropriate cavity preparation for a specific clinical situation. In this study, the cavities were prepared on maxillary first premolar and filled with gold inaly. A two - dimensional model was composed of 1037 - node triangle elements. In this model, isthmus was varied in width at 1/4, 1/3 and 1/2 of intercuspal width and material properties were given for four element groups, i.e., enamel, dentin, pulp and gold. The 500N occlusal load varied in direction and it was examined using three types of load : concentrated load, divided load and distributed load. The models were also examined with empty cavities using the devided load and distributed load. These models were analyzed the displacement and strees distribution by the two - dimensional Finite Element Method. The results were as follows : 1. All experimental models which filled with gold inlay after cavity preparation were similar direction of displacement with control model under same load type. But in the models with empty cavities, as isthmus width was wider, the degree of displacement was increased at same load type. 2. Among the experimental models which were filled with gold inaly after cavity preparation, the model II showed the least stress concentration under concentrated load and divided load. But in the models with empty cavities, the model III showed the largest stress concentration and tooth fracture is expected regardless isthmus width. 3. All experimental models showed similar displacement pattern beneath restorative material under a concentrated load. In the models with empty cavities, a divided load resulted in a lingual displacement of the lingual cusp, but a distributed load resulted in a buccal displacement of the lingual cusp. In regard to the above results, the restored models were stronger than empty models in respect to the bending moment and tensile stress. The empty models are expected to fracture regardless isthmus width. The safest isthmus width was 1/3 of intercuspal distance, which showed the least stress concentration in respect to the effect of stress distribution.

  • PDF