• Title/Summary/Keyword: Behavior detection

Search Result 935, Processing Time 0.026 seconds

Actinometric Investigation of In-Situ Optical Emission Spectroscopy Data in SiO2 Plasma Etch

  • Kim, Boom-Soo;Hong, Sang-Jeen
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.3
    • /
    • pp.139-143
    • /
    • 2012
  • Optical emission spectroscopy (OES) is often used for real-time analysis of the plasma processes. OES has been suggested as a primary plasma process monitoring tool. It has the advantage of non-invasive in-situ monitoring capability but selecting the proper wavelengths for the analysis of OES data generally relies on empirically established methods. In this paper, we propose a practical method for the selection of OES wavelength peaks for the analysis of plasma etch process and this is done by investigating reactants and by-product gas species that reside in the plasma etch chamber. Wavelength selection criteria are based on the standard deviation and correlation coefficients. Moreover, chemical actinometry is employed for the normalization of the selected wavelengths. We also present the importance of chemical actinometry of OES data for quantitative analysis of plasma. Then, the suggested OES peak selection method is employed.. This method is used to find out the reason behind abnormal etching of PR erosion during a series of $SiO_2$ etch processes using the same recipe. From the experimental verification, we convinced that OES is not only capable for real-time detection of abnormal plasma process but it is also useful for the analysis of suspicious plasma behavior.

The Optimized Monolithic Fault Protection Circuit for the Soft-shutdown behavior of 600V PT-IGBT by employing a New Blanking Filter (600V Punch-through형 절연 게이트 바이폴라 트랜지스터의 Soft-shutdown을 위해 시간 지연 회로를 적용한 새로운 보호회로)

  • Lim, Ji-Yong;Ji, In-Hwan;Ha, Min-Woo;Choi, Young-Hwan;Choi, Yearn-Ik;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1299-1300
    • /
    • 2006
  • Floating p-well 전압 감지를 이용한 시간 지연 회로를 적용하여 punch-though형 절연 게이트 바이폴라 트랜지스터 (PT-IGBT)의 최적화된 보호 회로를 제안하였다. Floating P-well 축전기와 게이트 저항은 정상 스위칭 동작시 단락 회로 감지 동작 (false detection of fault)을 차단하며, floating p-well 전압은 단락회로 상황시 풀-다운 (pull-down) MOSFET의 문턱 전압 이상으로 상승되어 풀-다운 MOSFET을 턴-온(turn-on) 시킴으로서 IGBT의 게이트 전압을 감소시킨다. 이에 따라 IGBT의 컬렉터 전류는 자연스럽게 감소된다. 실험 결과를 통해, 단락회로 상황에서 최적화된 IGBT의 보호회로가 소프트-셧다운 (soft-shutdown) 특성을 보이는 것을 확인할 수 있다.

  • PDF

A Comparison Study on Software Testing Efforts (소프트웨어 테스트 노력의 비교 연구)

  • Choe, Gyu-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.818-822
    • /
    • 2003
  • We propose a software-reliability growth model incoporating the amount of uniform and Weibull testing efforts during the software testing phase in this paper. The time-dependent behavior of testing effort is described by uniform and Weibull curves. Assuming that the error detection rate to the amount of testing effort spent during the testing phase is proportional to the current error content, the model is formulated by a nonhomogeneous Poisson process. Using this model the method of data analysis for software reliability measurement is developed. The optimum release time is determined by considering how the initial reliability R(x|0) would be. The conditions are $R(x|0)>R_o$, $R_o>R(x|0)>R_o^d$ and $R(x|0)<R_o^d$ for uniform testing efforts. Ideal case is $R_o>R(x|0)>R_o^d$. Likewise, it is $R(x|0){\geq}R_o$, $R_o>R(x|0)>R_o^{\frac{1}{g}$ and $R(x\mid0)<R_o^{\frac{1}{g}}$ for Weibull testing efforts. Ideal case is $R_o>R(x|0)>R_o^{\frac{1}{g}}$.

  • PDF

The Detection of Aflatoxin in Home-made Takju and Peanut butter (자가탁주와 땅콩버터에 대한 Aflatoxins 오염도의 검색)

  • 오유진;윤여표;여신구;홍진태
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.2
    • /
    • pp.171-176
    • /
    • 1986
  • ABSTRACT-In order to detect the aflatoxins in home-made Takju and peanut butter, the samples were collected in Chungbuk region and cleaned up Sep-pak silica cartridge. Aflatoxins were detected by thin layer chromatographic and high performance liquid chromatographic behavior. Determination was carried out by thin layer densitometer. The results were as follows; 1. Aflatoxin B, was detected in 78% of the home-made Takju, and the highest concentration was 1.2 ppb and average 0.36 ppb. 2. Aflatoxins were not detected in any peanut butter smaples. 3. Clean-up method by Sep-pak silica cartridge was more efficient and economical than column chromatography of AOAC method.method.

  • PDF

A study on Preventing Data Leakage using Abnormal Behavior Detection in a Virtual Private Network (VPN에서의 이상행동 탐지를 활용한 정보유출 방지에 관한 연구)

  • Park, Jang-Su;Kim, Su-Hyun;Lee, Im-Yeong
    • Annual Conference of KIPS
    • /
    • 2015.04a
    • /
    • pp.404-405
    • /
    • 2015
  • 최근 IT기술과 인터넷의 발전으로 시간과 공간에 제한을 두지 않고 업무를 처리해야 하는 상황으로 업무환경이 급격히 변화되고 있다. 특히 기업에서는 외부 네트워크와 정보교환의 필요성이 증가되었고, 구성원들의 잦은 외근, 출장 등 사무실 밖에서 업무를 처리하는 비중이 높아져, 내부뿐만 아니라 외부와의 정보공유를 하는데 있어 안전한 네트워크 구조를 요구하고 있다. 외부에서 효율적이고 안전하게 내부시스템에 접속할 수 있게 사용되는 것이 VPN(가상사설망: Virtual Private Network)으로, 기관 및 기업에서 VPN을 지속적으로 도입하여 운영하고 있다. 하지만 VPN에 인증이 성공되면 다양한 업무시스템에 접근이 용이하기 때문에, 악의적인 사용자로부터 정보유출이 손쉽게 이루어질 수 있다. 따라서 본 연구에서는 사용되고 있는 VPN에 대해 관리가 잘 이루어지는지 확인하는 실태점검 리스트를 제시하고, VPN에 대한 정보유출방지 모니터링을 위해 VPN의 접속로그를 분석하여 정보유출 보안위협행위를 탐지할 수 있는 시나리오를 도출하고자 한다.

Self-Organization of Swarm Robots Based on Color Recognition (컬러 인식에 기반을 둔 스웜 로봇의 자기 조직화 연구)

  • Jung, Hah-Min;Hwang, Young-Gi;Kim, Dong-Hun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.3
    • /
    • pp.413-421
    • /
    • 2010
  • In the study, self-organization by color detection is proposed to overcome required constraints for existing self-organization by an external ceiling camera and communication. In the proposed self-organization, each swarm robot can follow its colleague robot and all swarm robots can follow a target by LOS(Line of Sight). The swarm robots follow the moving target by the proposed potential field, avoiding confliction with neighboring robots and obstacles. Finally, all swarm robots are reached by a sight among swarm robots. In this paper, for unicycle robots with non-holonomic constraints instead of point robot with holonomic constraints self-organization is presented, it enhances the possibility of H/W realization.

Studies on the Spectrophotometric Determination and Electrochemical Behavior of Heavy Lanthanide Ions in Nonaqueous System and Heavy Metal Chelate Complexes with Bidentate Legands: (Part I) Flow Injection Spectrophotometric Determination of Heavy Lanthanide Ions with Xylenol Orange

  • Sam-Woo Kang;Chong-Min Park;Kwang-Hee Cho;Hong-Seock Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.59-62
    • /
    • 1993
  • Spectrophotometric determination of some heavy lanthanide ions by flow injection method is described. Xylenol Orange forms water soluble chelates with lanthanide ions in a tris[hydroxymethyl]-aminomethane-buffered medium having pH 8.3 and containing cetyltrimethylammonium bromide. The molar absorptivities of Ln(III)-XO complexes were increased by the ternary system with cetyltrimethylammonium bromide with the concomitant bathochromic shift of absorption maxium compared to those of the binary system without cetyltrimethylammonium bromide. The calibration curves are linear in the range 0.25-1.00 ppm for Gd(III), Dy(III), Er(III), Tm(III) and Yb(III) and the dynamic range are very wide. The detection limits (S/N=2) are from 2 ppb for Gd(III) to 30 ppb for Yb(III) and the relative standard deviations are from 1.2% for 0.5 ppm Gd(III) to 1.8% for 0.5 ppm Yb(III). The sample throughput was ca. 50 $h^{-1}$.

Quantitative detection of peri-implantitis bacteria using real-time PCR (Real-time PCR을 이용한 임플란트주위염 원인균의 정량적 분석)

  • Kim, Min-Jung;Han, Gyeong-Soon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.5
    • /
    • pp.555-565
    • /
    • 2021
  • Objectives: This study was conducted to analyze peri-implantitis bacteria and identify their associations with health status and health activities. Methods: Gingival sulcus fluid at the implant's periodontal pockets sampled from the participants were analyzed by multiplex real time PCR. Results: Participants had strains in the order of 100% F. nucleatum, 98.0% E. corrodens, and 96.0% P. micra, and the correlation between C. rectus and E. nodatum was high (p<0.01). Diabetic group (P. gingivalis, P. nigrescens) hypertension (P. nigrescens), group with four or more periodontal pockets (P. gingivalis, T. dentica, P. intermedia, E. nodatum, and C. rectum), smoking (P. micra, E. corrodens), drinking (T. dentola), and scaling groups (C. rectus) were found to have more strains (p<0.05). Conclusions: Representative pathogenic microorganisms detected in periodontal pockets of implants were similar to dental periodontal pockets; however there were differences in the amount and distribution of microorganisms, and they were affected by health status and health behavior.

Exploratory Study: A Modification Training Method of Attentional Bias Toward Safety

  • Gao, Jingqi;Wu, Xiang;Luo, Xiaowei;Zhang, Ao
    • Safety and Health at Work
    • /
    • v.12 no.3
    • /
    • pp.346-350
    • /
    • 2021
  • Background: The high sensitivity of individuals toward safety information in production activities, that is, attentional bias toward safety (ABS), can positively predict safe behaviors. It has become a hot topic in current organizational safety behavior research. However, there is no literature on its modification method. Methods: Based on the modified dot-probe task, we designed a modification training method of ABS. The training method required subjects to respond to the location of detection points that presented after safety stimulus and neutral stimulus pictures. Subjects' attentional bias values of safety and neutral pictures were measured during the experiment. Twenty-one students were selected and divided into a control group and training group to gain comparable results. Results: A novel training method was developed in this study to promote the efficacy of safety stimulus by activating ABS of the subjects. Moreover, repeated trainings and preacquired relative knowledge can enhance this effect. Conclusion: This study develops an experimental approach to evaluate the effectiveness of safety education and safety training, and also provides a new research idea for accident prevention.

A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave (유도초음파를 이용한 3/4″ 배관 결함 검출 연구)

  • Chung, Woo Geun;Kim, Jin-Hoi;Cheon, Keun Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.