• Title/Summary/Keyword: Before and after renovation

Search Result 29, Processing Time 0.035 seconds

Comparative Studies on the DM Yield and Quality Before and After Pasture Renovation of Summer Depression Damaged Pasture (하고 피해 초지의 갱신전과 후의 건물수량 및 사료가치 비교 연구)

  • 이인덕;이형석;김선균
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.20 no.3
    • /
    • pp.215-220
    • /
    • 2000
  • This study was conducted to evaluate the dry matter yield and quality of the before and after renovation of summer depression damaged pasture, and carried out at Chungnam National University ffom 1997 to 1999. The yield of DM in first and second year of after renovation, comparing with those of before renovation(6,547kg/ha), significantly increase obtained 12,291kglha and 13,50Ikg/ha, respectively(P<0.05). In the chemical composition, CP content and DM digestibility were markedly increased comparing with those of before renovation(P<0.05), but the contents of NDF, ADF, cellulose and lignin were decreased respectively(P<0.05). In the botanical composition, weeds after renovation was markedly decreased comparing with before renovation, but increased the percentage of herbage in summer depression damaged pasture. The results from this study, It is proved that a renovation method, which was conducted by two times of reseeding and raking, was effective in recovering botanical composition of herbage, and enhancing productivity and upgrading quality in summer depression damaged pasture. (Key words : Renovation, Reseeding, Summer depression)

  • PDF

Diagnosis and Renovation of a Time-worn Rapid Sand Filter used for Drinking Water Treatment (정수장의 노후 급속 모래여과지 진단 및 개량)

  • Kim, Sang-Goo;Park, Hyun-Seog;Son, Hee-Jong;Lee, Jeong-Gyu;Ryu, Dong-Choon;Yoo, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.999-1005
    • /
    • 2016
  • The H water treatment plant has been operating since 1982 and has had no renovation. It is assumed that the filters have been operated for more than 30 years and therefore are deteriorated. Many of the filters show an unequal state of air scouring during backwashing. For this study one filter, which was presumed most deteriorated among eighteen filters, was selected as a model filter for renovation. Some of the effects seen after renovation of the underdrain system were a lower average filtrated turbidity by approximately 0.02 NTU and an equal backwash state throughout the filter bed. Sand wash efficiencies by backwash before renovation of the underdrain system were 28%, 8%, and 5% at the surface, 50 cm depth, and 100 cm depth, respectively, and after renovation of the underdrain system were 94%, 26%, and 15%, respectively. The standard deviation of the effective sand size was 0.025-0.033 mm before renovation of the underdrain system and 0.002-0.011 mm after renovation of the underdrain system, meanings there was equal backwash pressure throughout the filter. Filtration time after renovation was approximately 2 times longer than before renovation.

The Concentration Variation of Volatile Organic Compounds before and after Renovation in Apartment Houses (아파트 개조 전후의 휘발성유기화합물 농도변화 실태)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Shin, Hae-Chul
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.59-67
    • /
    • 2007
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after renovation in apartment houses. The field measurements of TVOC and HCHO concentration according to the Korea Test Method Standard for Indoor Air Quality were carried out in 4 subject apartment houses. The results are as follows; the TVOC concentration after renovation in apartment houses ranged from mean 0.35ppm to mean 5.08ppm and increased of $0.35{\sim}5.08ppm$. The TVOC concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.58ppm). The HCHO concentration after renovation ranged from mean 0.13ppm to mean 0.43ppm and increased of $0.06{\sim}0.26ppm$. The HCHO concentration of 2 subjects exceeded the Standard (0.17ppm). As results of analysis on the relation of concentrated ascension and renovation elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

Variations in Multi-family House Prices Following Remodeling Work

  • Kim, Jae-sung;Cho, Kyuman
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.689-690
    • /
    • 2015
  • The remodeling of multi-family houses (MFH) has emerged as a significant issue in the construction industry. Many decision makers struggle with the decision to remodel because of insufficient information including standards or methods for projecting the price of their structure after remodeling. In this context, this research analyzed the change in price of MFHs after remodeling. To achieve this research goal, (i) the price data from 14 groups (i.e., MFH renovation cases and equivalent MFH cases without remodeling) were collected, and (ii) the trend of price variation among each group was analyzed. Finally, this research suggests price variations of each group in terms of three different time points (i.e., before remodeling, after remodeling, and the present), which shows the effects of remodeling on the price of MFHs. This research offers a framework for the development of a model that will predict the price of an MFH after remodeling.

  • PDF

Evaluation of Ventilation Effectiveness Before and After Kitchen Renovation in Schools of Gyeongsangnam-do (경남지역 학교 급식조리실 개선 전후 환기성능 평가)

  • Jongwon Son;Taehyeung Kim;Hyunchul Ha;Byounghoon Kim;Kritana Prueksakorn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.35-47
    • /
    • 2024
  • Objectives: Many cases of lung cancer have been reported by school kitchen workers as occupational cancer. Twenty-eight schools in Gyeongsangnam-do Province were selected to evaluate the effect of improved kitchen ventilation systems. Ventilation characteristics before and after renovation were compared and design techniques were identified. Methods: In the design stage for kitchen ventilation systems, expert intervention was used to improve the designs. Ventilation characteristics and air quality were evaluated before and after the renovations. Hood face velocity and fan flow rate were measured and the smoke visualization technique was used to evaluate the capability of protecting worker's breathing zone. The concentrations of PM0.3 were measured at points not adjacent to cooking equipment because these concentrations fluctuate greatly. Results: Mean hood face velocity increased from 0.29 m/s before renovation to 0.7m/s after renovation. The concentrations of PM0.3 showed a roughly 95% reduction. Concentrations of CO showed more than a 75% reduction. Smoke visualization showed greater protection of workers' breathing zone. Conclusions: Advanced design techniques for school kitchen ventilation systems were applied to renovate old kitchen ventilation systems. The performance of the new kitchen ventilation systems was nearly excellent. Further improvement of design techniques is still needed, however.

Assessment of fish stocks and economic value in accordance with fishway renovation: Case study of Samcheokoshipcheon0010 Weir (어도 개보수에 따른 어류 자원량 및 경제적 가치 평가: 삼척오십천 사례)

  • Moon, Woon-Ki;Bae, Dae-Yeul;Kim, Do-Hyun;Shin, Hyun-Beom;Suh, Jung Bin;Lim, Kyeong Hun;Lee, Eui-Haeng;Yoo, Jae-Sang;An, Kwang-Guk;Kim, Jai-Ku
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.30-39
    • /
    • 2020
  • The changes in fish stock and biomass before and after fishway renovation located in a Korean estuary were studied and fluctuations in the economic value of the fish resources were estimated. The target fishway located in the east coast area in Korea was renovated in 2014 from the small fish ladder to the ice-harbor fishway. Monitoring was continued for five consecutive years after the renovation(2015 to 2019). Since the renovation of the fish passage, the economic values increased with increases in the fishery resources, except for in 2016 when the drought impact was severe. The yearly average incremental increase in the five years after the renovation was about 227%. The increase in economic value is believed to be due to the increased population of migratory fish as a result of habitat expansion. The exponential rise model showed an increase in economic value with increasing fishery resources (R2=0.896). The model coefficient contributing to economic analysis was 0.582 and the maximum economic value after the renovation was estimated at about 30.4 million. The economic value would be a useful index for quantitative comparison in terms of ecosystem services before and after renovation.

Evaluation on Reduction Effect of Dam Hydraulic Turbine Dynamo Noise using Auralization (가청화를 이용한 댐 수차 발전기소음의 저감효과 평가)

  • Jung, Eun-Jung;Jung, Chul-Woon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.253-257
    • /
    • 2007
  • In case of the hydraulic turbine dynamo room at Dam, due to its big volume and reflexible finishing material, since the noise of electricity-generation is amplifying, it influences the difficulty of mutual communication among the workers, also it is causing both mental and physical damages to those workers in the neighboring office. Accordingly, after presentation of the optimized renovation model of the hydraulic turbine dynamo room using the acoustic simulation, this Research has compared and evaluated them using the auralizational technique between the present condition of "before improvement" and the acoustic condition of "after improvement". As the result of psycho-acoustics experiment, as the acoustic conditions at both "before & after Improvement" were apparently compared, it appeared that there is a considerable amount of noise-reduction effect at psycho-acoustics. It is considered that such material could be utilized as the valuable data hereafter for the time when any construction and renovation of the hydraulic turbine dynamo room and other similar workshop.

  • PDF

An Effects of Air-Assisted-Catalyst Element for Reducing Density of Formaldehyde in a New House (신축주택에서 포름알데히드 농도저감에 대한 공기 촉매제의 효과에 관한 연구)

  • Jo, Hyeon-U;Park, U-Yeol;Jo, Hun-Hui;Jo, Ho-Gyu;Gang, Gyeong-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • The sick house syndrome is occurred from the harmful elements that the building interior materials are given off after building construction or renovation. The appropriate methods, which is to prevent sick house syndrome from spreading have to be selected before building construction or renovation. Thus, this study is to measure the density of formaldehyde, one of the volatile organic compounds after sprinkling air-assisted-catalyst on the building interior space. As a result, the emit value of formaldehyde is measured 0.07ppm that is lower than the standard of Environmental Protection Agency and World Health Organization, 0.1ppm, and the standard of Ministry of Health, Labour, and Welfare of Japan, 0.08ppm.

Seismic behavior of caisson-type gravity quay wall renovated by rubble mound grouting and deepening

  • Kim, Young-Sang;Nguyen, Anh-Dan;Kang, Gyeong-O
    • Geomechanics and Engineering
    • /
    • v.27 no.5
    • /
    • pp.447-463
    • /
    • 2021
  • Caisson-type structures are widely used as quay walls in coastal areas. In Korea, for a long time, many caisson-type quay walls have been constructed with a low front water depth. These facilities can no longer meet the requirements of current development. This study developed a new technology for deepening existing caisson-type quay walls using grouting and rubble mound excavation to economically reuse them. With this technology, quay walls could be renovated by injecting grout into the rubble mound beneath the front toe of the caisson to secure its structure. Subsequently, a portion of the rubble mound was excavated to increase the front water depth. This paper reports the results of an investigation of the seismic behavior of a renovated quay wall in comparison to that of an existing quay wall using centrifuge tests and numerical simulations. Two centrifuge model tests at a scale of 1/120 were conducted on the quay walls before and after renovation. During the experiments, the displacements, accelerations, and earth pressures were measured under five consecutive earthquake input motions with increasing magnitudes. In addition, systematic numerical analyses of the centrifuge model tests were also conducted with the PLAXIS 2D finite element (FE) program using a nonlinear elastoplastic constitutive model. The displacements of the caisson, response accelerations, deformed shape of the quay wall, and earth pressures were investigated in detail based on a comparison of the numerical and experimental results. The results demonstrated that the motion of the caisson changed after renovation, and its displacement decreased significantly. The comparison between the FE models and centrifuge test results showed good agreement. This indicated that renovation was technically feasible, and it could be considered to study further by testbed before applying in practice.

Ecological Change in Drainage Channel Site Renovated by Environment Friendly Methods (환경친화적 정비에 따른 배수로의 생태변화)

  • Yang, Yong-Seok;Kim, Sun-Joo;An, Min-Woo;Choi, Kyoung-Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.12 no.3 s.32
    • /
    • pp.19-28
    • /
    • 2006
  • This study has been conducted to perform the survey on the ecological systems, scenary, and water quality change for agriculturally purposed drainage channels constructed with the application of environment-friendly methods and thus to evaluate the environment-friendly redevelopment effects of them. The main results of this study are as follow: 1. The channels not looking good aesthetically before redevelopment had changed into graceful scenic views from the aspect of landscape architecture as natural-type gently waterside to the channel and naturally-looking water stream. In the village parks developed for the rest of residents, an enough view was secured and thus a wide prospect scope could be obtained. 2. The flora in the channels have increased to 35 families and 82 species from 19 families and 32 species before renovation. As the growth speed of them are slower than externally-brought plants, they can cause some risks to the stability of land slope, including scour by erosion. From that reason, it is necessary to adequately combine the species of the plants both natively growing there and externally-brought planted. 3. In case of water quality, it turned out that, from more than a year after redevelopment, plants began to take roots and the water quality improved. On the contrary, there have been some cases, partly found, that aggravated the quality of water due to the causes like as retention of floating matters by withered plants or plant bodies after the growth of plants in the channels under survey became active, and therefore it is judged that a periodic maintenance of waterways is needed. 4. In case of fishes, all species before renovation have revived, and the population and the number of species have increased after works the formation of puddles in the channels. In waterside grasslands, amphibia and reptiles have not only increased but also been diversified.