• 제목/요약/키워드: Beam quality

검색결과 1,057건 처리시간 0.024초

빔 쉐이핑된 펨토초 레이저를 이용한 터치스크린 패널의 ITO 박막 패터닝 (Patterning of ITO on Touch Screen Panels using a beam shaped femtosecond laser)

  • 김명주;김용현;윤지욱;최원석;조성학;최지연
    • 한국레이저가공학회지
    • /
    • 제16권4호
    • /
    • pp.1-6
    • /
    • 2013
  • Femtosecond laser patterning of ITO on a touch screen panel with a shaped fs laser beam was investigated. A quasi flat-top beam was formed using a variable mask and a planoconvex lens. The spatial profile of the original Gaussian beam and the shaped beam were monitored by a CCD beam profiler. The laser patterned ITO film was examined using an optical microscope, Scanning Electron Microscope (SEM) with Energy Dispersive X-ray Spectroscopy (EDS), and Atomic Force Microscope (AFM). It turned out that the quality of the ITO pattern fabricated by a shaped beam is superior to that of the pattern without beam shaping in terms of debris generation, height of the craters, and homogeneity of the bottom. Optimum processing window was determined at the laser irradiance exhibiting 100% removal of Sn. The removal rate of In was measured to be 83%.

  • PDF

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.

Investigation of Standard Evaluation for the Quality Control of General X-ray Systems

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Byoung-Jun;Park, Deok-Woo;Jung, Byoung-Hoon;Lee, Hyo-Jin;Hong, Ji-Young;Kim, Seung-Chul
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • Thanks to the great development of technology in radiation, we are now able to reduce radiation exposure to the patients, and the radiographer and expenses in medical sector. We are also trying to produce ideal images which maintain useful information. These kinds of effort are increasing over the world. For that reason, we should get images which include necessary data of patients. Then it also can help to reduce radiation exposure to the patients. Therefore, we need to know the problems that cause a falling off in image's quality and check on generator in case of their electronic and mechanical errors. And moreover, we should anticipate the possibility of devices errors and prevent them with regular quality control. This investigation was conducted in medical institutions, institute of educations and hospitals. They are all in Seongnam-City. We used PMX-III, kVp meter to implement kVp test, mR / mAs output test, light fiel / beam alignment test, Reproducibility of exposure dose, half value layer test, reproducibility of exposure time test. in the case of hospitals, they perceive the importance of regular quality control and organize the regular quality control team so they can be satisfied with the error standard in most experiments. On the other hand, when it comes to medical institutions and institute of educations, they perceive the importance of regular quality control less than hospitals do. Radiographer need to understand the importance of regular quality control and practice it so they can get the fine ideal image with the lower dose to the patient.

  • PDF

수입 및 국산 용지를 사용한 지도 인쇄물의 내마모성 및 내광성에 관한 비교 연구 (Comparison Study on abrasion resistance and beam endurance of map printing using the import and domestic paper)

  • 강영수;신종순;강영립
    • 한국인쇄학회지
    • /
    • 제20권1호
    • /
    • pp.54-64
    • /
    • 2002
  • For the efficient work of map printing and quality improvement, we experimented on abrasion-resistance and beam-endurance of 5 kinds of map papers (offset paper, art paper, domestic map paper, foreign map paper, and Tyvek paper). The results obtained that imported and domestic map paper were superior to the others in endurance-proof.

  • PDF

파이버 레이저에 의한 고속 키 홀 용접 (High speed key-hole welding by fiber laser)

  • 박서정;장웅성;천창근;주성민
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년도 춘계 학술대회 개요집
    • /
    • pp.195-197
    • /
    • 2006
  • The present study examined the characteristics of high speed welding thin metal sheet using single mode fiber laser of averaged maximum output power 300 W. Due to the fiber laser that has a good quality of beam can make a very small focusing beam size, thin metal sheet welding and high speed key hole welding can be peformed by high power density.

  • PDF

The use of Power Beam Welding Technology in Manufacturing Industry

  • J-Sims;Punshon, C-S;Riches, S-T
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1994년도 특별강연 및 춘계학술발표 개요집
    • /
    • pp.1-20
    • /
    • 1994
  • In order for manufacturing companies to remain competitive it Is necessary for them to review continually their fabrication methods. The use of power beams for welding and cutting offer significant opportunities for industry to improve its product quality and increase profitability. This paper discusses a number of current industrial applications for electron beam and laser welding.

  • PDF

호흡동조 양성자치료의 Quality Verification (Quality Verification for Respiratory Gated Proton Therapy)

  • 김은숙;장요종;박지연;강동윤;염두석
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.107-113
    • /
    • 2013
  • 목 적: 호흡동조 시스템을 이용한 양성자치료 시 생성되는 양성자빔을 측정하고 분석함으로써 호흡동조 양성자치료의 정확성을 검증하고자 한다. 대상 및 방법: 호흡동조 양성자치료를 실시한 환자 세 명의 치료계획을 이용하여 양성자 치료 시스템에서 양성자빔을 생성했다. 이때 자체 제작한 구동 팬톰을 사용하여 호흡동조 시스템을 적용해 분할 조사되는 양성자빔을 재현하였다. 양성자빔의 중요특성인 Range, Spread-Out Bragg Peak (SOBP), Output factor를 각 5회씩 측정하였으며 호흡동조 시스템을 적용하지 않은 연속 양성자빔에서도 동일한 항목들을 측정했다. Range와 SOBP 측정에는 Multi-Layer Ionization Chamber, Output factor 측정에는 Scanditronix Wellhofer와 Farmer chamber를 사용했다. 결 과: 호흡동조 시스템을 적용한 경우 세 환자의 평균 Range는 7.226, 12.216, 19.918 $g/cm^2$, SOBP는 4.950, 6.496, 8.486 $g/cm^2$, Output factor는 0.985, 1.026, 1.138 cGy/MU였으며, 적용하지 않은 경우 평균 Range는 7.230, 12.220, 19.920 $g/cm^2$, SOBP는 4.940, 6.512, 8.490 $g/cm^2$, Output factor는 0.984, 1.027, 1.136 cGy/MU로 측정됐다. 평균 Range의 차는 -0.004, -0.004, -0.002 $g/cm^2$, SOBP는 0.010, -0.016, -0.004 $g/cm^2$, Output factor는 0.001, -0.001, 0.002 cGy/MU로 나타났다. 결 론: 호흡동조 양성자치료 시 분할 조사된 양성자빔과 연속 조사된 양성자빔의 Range, SOBP 및 Output factor 모두 차이가 미미했다. 따라서 본 연구를 통해 호흡동조 시 발생된 양성자빔의 선질을 검증하였고 이를 이용한 양성자치료의 정확성 또한 확인할 수 있었다.

  • PDF

Laser Welding Quality Monitoring with an Optical Fiber System

  • Kim, Jin-Tae;Kim, Do-Hyoung;Chung, Chin-Man;Baik, Sung-Hoon;Park, Seung-Kyu;Kim, Min-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제7권3호
    • /
    • pp.193-196
    • /
    • 2003
  • We have developed a laser welding monitoring system to monitor laser welding process conditions such as sample feed rate, laser focal position, and laser power. A 2 ㎾ Nd:YAG CW laser beam has been applied to the welding of a stainless steel plate (SUS306) to investigate the welding monitoring. Theradiation signal from the weld pool was guided back through the focusing optics and the laser delivery fiber, and measured by a photo detector. By changing the focus of the laser beam along the z-direction, the penetration depth of the welding material has been measured. That shows the penetration depth depends on the frequency fluctuations of the plume signals which can be used in welding quality control.

승용차 부품의 정면밀링가공시 공구마모 및 표면거칠기 특성에 관한 연구 (A Study on Characteristics of Tool Wear and Surface Roughness in Face Milling of Automobile Parts)

  • 김성일;오성훈;문상돈;김태영
    • 한국자동차공학회논문집
    • /
    • 제4권5호
    • /
    • pp.223-230
    • /
    • 1996
  • The quality and productivity in machining automobile parts are influenced by various factors such as cutting conditions, vibration, and used tool. To improve the quality and productivity of the automobile parts(torsion beam), lots of research on the evaluation of tool life and control of surface roughness has been required. Therefore, the width of flank wear, cutting force, and surface roughness are monitored to analyse the characteristics of tool wear and surface roughness at different tools. This experimental investigation is mainly focused on the characteristics of the tool wear, tool life and surface roughness in multi-insert milling of automobile parts(torsion beam) by using uncoated tungsten carbide tool(WC), TiN coated tool, and cermet tool.

  • PDF