• Title/Summary/Keyword: Beam quality

Search Result 1,060, Processing Time 0.026 seconds

A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy

  • Chung, Kwangzoo
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.129-133
    • /
    • 2017
  • The machine log files recorded by a scanning control unit in proton beam therapy system have been studied to be used as a quality assurance method of scanning beam deliveries. The accuracy of the data in the log files have been evaluated with a standard calibration beam scan pattern. The proton beam scan pattern has been delivered on a gafchromic film located at the isocenter plane of the proton beam treatment nozzle and found to agree within ${\pm}1.0mm$. The machine data accumulated for the scanning beam proton therapy of five different cases have been analyzed using a statistical method to estimate any systematic error in the data. The high-precision scanning beam log files in line scanning proton therapy system have been validated to be used for off-line scanning beam monitoring and thus as a patient-specific quality assurance method. The use of the machine log files for patient-specific quality assurance would simplify the quality assurance procedure with accurate scanning beam data.

Evaluation of Nd:YAG Laser Beam Quality in Unstable Rosonators (불안전형 공진기를 갖는 Nd:YAG 레이저에서의 beam quality 평가)

  • 김광석;김정묵;김철중;이종민
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.60-66
    • /
    • 1994
  • First, the beam waist size of TE$M_{00}$ Nd:YAG laser mode with Positive Branch Unstable Resonator was calculated. and then, the output power, fundamental mode and multimode beam quality factor of PBUR were measured and compared with thouse of reference resonator with plane pallalel mirrors. In characterizing the beam quality, the $M^2$ concept was used. The focusability of laser beam in unstable resonators was discussed with this $M^2$.

  • PDF

Improvement of Beam-Quality Evaluation Method for Medical Linear Accelerator Using Magnetic Field

  • Kim, Jeongho;Han, Manseok;Yoo, Sejong;Kim, Kijin;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.120-128
    • /
    • 2015
  • Beam-quality of medical linac evaluations vary by diverse factors. Because conventional beam-quality evaluation methods yield fragmentary results, a new beam-evaluation method is suggested, and its feasibility is evaluated. The PDDs (percentage depth doses) of 6 MV (Mega-voltage) and 10 MV photon, R (Range) of a 6 MeV (Mega Electron-voltage) and 9 MeV electron were measured and compared with the conventional evaluation methods, and the improved methods $PDD^{10}{_5}$, $PDD^{20}{_{10}}$, $PDD^{30}{_{20}}$, $PDD^{20}{_5}$, $PDD^{30}{_{10}}$, and $R^{70}{_{50}}$, $R^{50}{_{30}}$, $R^{70}{_{30}}$ as the magnetic field of the bending magnet was changed to +2% to -2%, and the results were compared. The comparison showed that the improved methods exhibit a higher discrimination than the conventional methods in each energy regime. $PDD^{10}{_5}$, $PDD^{30}{_{20}}$, $PDD^{30}{_{10}}$ and $R^{70}{_{50}}$, $R^{50}{_{30}}$ should be applied. These methods exhibit a higher discrimination in each energy regime than conventional beam-quality evaluation methods; therefore, they should be used for beam-quality evaluation according to the magnetic field variation.

Impact of the Spectral Linewidth of a Pseudorandom Binary Sequence (PRBS)-Modulated Laser on Stimulated Brillouin Scattering and Beam Quality

  • Aeri Jung;Sanggwon Song;Kwang Hyun Lee;Jung Hwan Lee;Kyunghwan Oh
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.665-672
    • /
    • 2023
  • This study focuses on investigating the impact of the spectral linewidth of a seed laser in a master-oscillator power amplifier (MOPA) configuration on stimulated Brillouin scattering and the beam quality of the output diffracted by a grating. To conduct the study, a distributed feedback (DFB) laser is modulated in a pseudorandom binary sequence (PRBS) and amplified by a two-stage Yb-doped fiber amplifier to achieve an output power of over 1 kW. The spectral linewidth of the seed laser is systematically varied from 1 to 12 GHz in the frequency domain by varying the PRBS modulation parameters. The experimental results reveal a tradeoff between suppressing stimulated Brillouin scattering and enhancing beam quality with increased spectral linewidth. Therefore, the study provides valuable insights into optimizing spectral beam combining to achieve high beam quality and scalable power upgrade in fiber lasers.

Dose Effect of Phytosanitary Irradiation on the Postharvest Quality of Cut Flowers

  • Kwon, Song;Kwon, Hye Jin;Ryu, Ju Hyun;Kim, Yu Ri
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.2
    • /
    • pp.171-178
    • /
    • 2020
  • The present study was conducted to determine the effects of electron beam irradiation on the postharvest quality of cut flowers. Cut flowers were irradiated with electron beam at 100, 200, 400, 600, 800, 1,000, and 2,000 Gy with a 10 MeV linear electron beam accelerator to evaluate their irradiation tolerance. Postharvest quality was determined by monitoring fresh weight loss, flower longevity, flower diameter, flowering rate, visual quality of flowers and leaves, and chlorophyll content. Cut flowers showed a radiation-induced damage with increasing the irradiation dose. Flower longevity and fresh weight of cut flowers decreased when the irradiation dose was increased. Flower bud opening was also inhibited in a dose-dependent manner. The effective irradiation doses for 10% reduction of postharvest quality (ED10) values were 144.4, 451.6, and 841.2 Gy in the 'Medusa' lily, 'Montezuma' carnation, and 'Rosina White' eustoma, respectively. Although tolerance of cut flowers to electron beam irradiation vary according to species, cultivars, or maturity stage conditions, it is conceivable that 'Montezuma' carnation and 'Rosina White' eustoma could be tolerated and maintained overall postharvest quality up to 400 Gy, the generic irradiation dose approved by the Animal and Plant Health Inspection Service (APHIS) and the International Plant Protection Convention (IPPC) for postharvest phytosanitary treatments.

Beam Focusing Performance of Electrostatic Lens using SIMION Simulator (SIMION 시뮬레이터를 이용한 정전렌즈의 빔 집속 성능)

  • Oh, Maeng-Ho;Jeong, In-Sung;Lee, Jong-Hang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.128-133
    • /
    • 2009
  • Focused-ion-beam (FIB) system is capable of both machining and measuring in nano-scale; hence nano-scale focusing quality is important. This paper investigates design parameters of two electrostatic lenses in order to achieve the best ion beam focusing performance. Commercial SIMION simulator is used to optimize the dimensions of the condenser and objective lenses and investigate the influence of assembly error on focusing quality The simulation results show that the beam focusing quality is not influenced by angle deviation within ${\pm}0.02\;deg$ and geometrical eccentricity within ${\pm}50$ micrometers.

Prediction of Laser Process Parameters using Bead Image Data (비드 이미지 데이터를 활용한 레이저 공정변수 예측)

  • Jeon, Ye-Rang;Choi, Hae-Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.8-14
    • /
    • 2022
  • In this study reports experiments were conducted to determine the quality of weld beads of different materials, Al and Cu. Among the lasers used to make battery cells for electric vehicles, non-destructive testing was performed using deep learning to determine the quality of beads welded with the ARM laser. Deep learning was performed using AlexNet algorithm with a convolutional neural network structure. The results of quality identification were divided into good and bad, and the result value was derived that all the results were in agreement with 94% or more. Overall, the best welding quality was obtained in the experiment for the fixed ring beam output/variable center beam output, in the case of the fixed beam (ring beam) 500W and variable beam (center beam) 1,050W; weld bead failure was seldom observed. The tensile force test to confirm the reliability of welding reported an average tensile force of 2.5kgf/mm or more in all sections.

Measurement of Spatial coherence function and Directional coherence function of Propagating Laser Beam by using Wigner Distribution Function

  • Lee, Chang-Hyuck;Kang, Yoon-Shik;Noh, Jae-Woo
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.449-450
    • /
    • 2009
  • The spatial coherence and propagation property of laser beam propagating through several optical components were studied experimentally by using the measurement of Wigner distribution function. It is shown experimentally that the Wigner function measurement yields total degree of coherence, beam quality parameter, and the near and the far field information of the propagating beam. More complete characterization of the laser beam was achieved by applying the Schmidt mode decomposition to the Wigner distribution function, spatial coherence function and directional coherence function. Fine details of coherence property are understood by the characteristics of the contributing eigenmodes.

  • PDF

Simultaneous Optimization of Multiple Quality Characteristics in Laser Beam Cutting Using Taguchi Method

  • Dubey, Avanish Kumar;Yadava, Vinod
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.4
    • /
    • pp.10-15
    • /
    • 2007
  • Taguchi methods have been used for a long time to improve the product quality and process performance of a manufacturing system, Few researchers have applied this methodology in laser beam cutting (LBC) of sheet metals and found the considerable improvement in cut qualities. In all experimental investigations of LBC so far, the objective was to optimize the single quality characteristic at a time. In this paper the simultaneous optimization of multiple quality characteristics such as Kerf width and material removal rate (MRR) during pulsed Nd:YAG LBC of thin sheet of magnetic material (high Silicon-steel) has been presented using Taguchi's quality loss function. The results show the considerable improvement in multiple S/N ratio as compared to initial cutting condition. Also, the comparison of results from single and multi-objective optimization have been presented and it was found that the loss in quality is always possible shifting from single quality to multiple quality optimization.