• Title/Summary/Keyword: Beam extraction

Search Result 151, Processing Time 0.026 seconds

Design and simulation of 500 MHz single cell superconducting RF cavity for SILF

  • Yanbing Sun;Wei Ma;Nan Yuan;Yulin Ge;Zhen Yang;Liping Zou;Liang Lu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.195-206
    • /
    • 2024
  • Shenzhen Innovation Light source Facility (SILF) is a 3.0 GeV fourth generation diffraction limited synchrotron light source currently under construction in Shenzhen. The SILF storage ring is proposed to use two 500 MHz single cell superconducting radio frequency (SRF) cavities to provide 2.4 MV RF voltage. In this study, we examined the geometric structure of mature CESR superconducting cavities and adopted a beam-pipe-type extraction scheme for high-order modes (HOM). One of the objectives of SRF cavity design and optimization in this study is to reduce Ep/Eacc and Bp/Eacc as much as possible to reduce power loss and ensure stable operation of the cavity. To reduce the risk of beam instability and thermal breakdown, the HOM and Multipacting (MP) are simulated. Moreover, the mechanical properties of the cavity are analyzed, including frequency sensitivity from pressure of liquid helium (LHe), stress, tuning, Lorentz force detuning (LFD), the microphone effect, and buckling. By comprehensive design and optimization of 500 MHz single-cell SRF cavities, a superconducting cavity for SILF storage ring was developed. This paper will detailed present the design and simulation.

Gene Expression Biodosimetry: Quantitative Assessment of Radiation Dose with Total Body Exposure of Rats

  • Saberi, Alihossein;Khodamoradi, Ehsan;Birgani, Mohammad Javad Tahmasebi;Makvandi, Manoochehr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8553-8557
    • /
    • 2016
  • Background: Accurate dose assessment and correct identification of irradiated from non-irradiated people are goals of biological dosimetry in radiation accidents. Objectives: Changes in the FDXR and the RAD51 gene expression (GE) levels were here analyzed in response to total body exposure (TBE) to a 6 MV x-ray beam in rats. We determined the accuracy for absolute quantification of GE to predict the dose at 24 hours. Materials and Methods: For this in vivo experimental study, using simple randomized sampling, peripheral blood samples were collected from a total of 20 Wistar rats at 24 hours following exposure of total body to 6 MV X-ray beam energy with doses (0.2, 0.5, 2 and 4 Gy) for TBE in Linac Varian 2100C/D (Varian, USA) in Golestan Hospital, in Ahvaz, Iran. Also, 9 rats was irradiated with a 6MV X-ray beam at doses of 1, 2, 3 Gy in 6MV energy as a validation group. A sham group was also included. After RNA extraction and DNA synthesis, GE changes were measured by the QRT-PCR technique and an absolute quantification strategy by taqman methodology in peripheral blood from rats. ROC analysis was used to distinguish irradiated from non-irradiated samples (qualitative dose assessment) at a dose of 2 Gy. Results: The best fits for mean of responses were polynomial equations with a R2 of 0.98 and 0.90 (for FDXR and RAD51 dose response curves, respectively). Dose response of the FDXR gene produced a better mean dose estimation of irradiated "validation" samples compared to the RAD51 gene at doses of 1, 2 and 3 Gy. FDXR gene expression separated the irradiated rats from controls with a sensitivity, specificity and accuracy of 87.5%, 83.5% and 81.3%, respectively, 24 hours after dose of 2 Gy. These values were significantly (p<0.05) higher than the 75%, 75% and 75%, respectively, obtained using gene expression of RAD51 analysis at a dose of 2 Gy. Conclusions: Collectively, these data suggest that absolute quantification by gel purified quantitative RT-PCR can be used to measure the mRNA copies for GE biodosimetry studies at comparable accuracy to similar methods. In the case of TBE with 6MV energy, FDXR gene expression analysis is more precise than that with RAD51 for quantitative and qualitative dose assessment.

Development of ISI UT Auto Flaw Evaluation and Acceptance Module of Nuclear Power Plants (원전 ISI UT 자동 결함평가 및 판정 모듈 개발)

  • Park, Ik-Keun;Park, Un-Su;Kim, Hyun-Mook;Kim, Chung-Seok;Um, Byong-Guk;Lee, Jong-Po
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.212-218
    • /
    • 2000
  • The importance and role of pre-/in-service inspection(PSI/ISI) for nuclear power plant(NPP) components are intimately related to plant design, safety, reliability, operation, etc. In this paper, for an effective and efficient management of large amounts of PSI/ISI data in NPPs, an intelligent database program(WS-IDPIN) for PSI/ISI data management of NPP was developed. WS-IDPIN program enables the prompt extraction of previously conducted PSI/ISI conditions and results so that the time-consuming data management, painstaking data processing and analysis in the past are avoided. Furthermore, development of ISI UT auto flaw evaluation and acceptance module based on ASME Code Sec. XI were presented. This module can be used for any angle beam examination from flat plate to spherical shapes as selected by the proper azimuthal angle. This program can be further developed as a unique PSI/ISI data management expert system.

  • PDF

Oroantral communication, its causes, complications, treatments and radiographic features: A pictorial review

  • Shahrour, Rama;Shah, Priya;Withana, Thimanthi;Jung, Jennifer;Syed, Ali Z
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.307-311
    • /
    • 2021
  • Purpose: An oroantral communication (OAC) is an abnormal space between the maxillary sinus and oral cavity. The causes, complications, treatment, and radiographic features of OAC in 2-dimensional and 3-dimensional imaging modalities are discussed. Materials and Methods: This pictorial review presents a broad spectrum of imaging findings of OAC. Representative radiographs depicting OAC were chosen from our database. PubMed was used to conduct a comprehensive literature search of OAC. Results: Characteristic features of OAC include discontinuity of the maxillary sinus floor, thickening of the maxillary sinus mucosa, or a combination of both. Two-dimensional imaging modalities are the method of choice for identifying discontinuities in the maxillary sinus floor. However, 3-dimensional imaging modalities are also essential for determining the status of soft tissue in the maxillary sinus. Conclusion: The integration of 2-dimensional and 3-dimensional imaging modalities is crucial for the correct diagnosis and comprehensive treatment of OAC. However, the diagnosis of OAC must be confirmed clinically to prevent unnecessary mental and financial burdens to patients.

Recurrent benign cementoblastoma: A case report and literature review

  • Yoon, Yeong-Ah;Kwon, Young-Eun;Choi, So-Young;Choi, Karp-Shik;An, Seo-Young;An, Chang-Hyeon
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.447-454
    • /
    • 2021
  • A 16-year-old male presented with pain in the right posterior mandible on chewing that had lasted for several months. The radiographic features of the lesion included a radiolucent-radiopaque mixed-density mass with a radiolucent rim attached to the root of the mandibular right first molar. The preliminary radiographic diagnosis was benign cementoblastoma, which was confirmed by histopathological examination following surgical excision. The lesion recurred 3 years after treatment; radiographically, it consisted of 3 round foci with mixed radiopacity, each with a radiolucent rim near the root of the mandibular right second premolar and the edentulous postoperative region. The lesion was diagnosed as recurrent benign cementoblastoma and a second surgery was scheduled. This report presented an unusual case of recurrent benign cementoblastoma following surgical excision and extraction of the involved tooth, along with a literature review on reported cases of recurrent benign cementoblastoma with a focus on its clinical features and the best treatment options.

Retrospective study on three-dimensional characteristics of mesiodens using CBCT in pediatric dentistry (치과용 Cone-beam CT를 이용한 상악 정중과잉치의 3차원적 특성에 관한 후향적 연구)

  • Ryu, GiYoun;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.77-94
    • /
    • 2021
  • The purpose of this study was to investigate the three-dimensional characteristics of mesiodens using Cone-beam Computed Tomography(CBCT) and analyze the factors affecting complications and anesthetic methods of extraction. This study evaluated 602 mesiodens of 452 patients who underwent extraction of mesiodens at the department of Pediatric Dentistry in Seoul National University Dental Hospital between 2017 and 2019. The ratio of mesiodens patients over total patient per year was gradually increased over the past 20 years. Mesiodens with labio-palatally horizontal direction while root directing labial were the most common among the mesiodens with horizontal direction. Mesiodens were the most common at the cervical side of the adjacent teeth(37.0%) and mesiodens located in the near-palatal side were observed about 3.83 times higher than the far-palatal side. Most of the mesiodens(82.1%) were in contact with adjacent permanent teeth on all three sides of the CBCT and 46.2% of mesiodens had curved roots. The patient's age, vertical position, presence of complications, and proximity showed a significant difference in the selection of general anesthesia among anesthetic methods. The direction and vertical position of mesiodens had a significant effect on complications. These results provide a better understanding of mesiodens for establishing an accurate diagnosis and treatment plan.

The Development of Topographic Feature Extraction Method by use of the Seafloor Curvature Measurement (곡률 계산에 의한 해저면 지형요소 추출 기법 개발)

  • Kim, Hyun-Sub;Jung, Mee-Sook;Park, Cheong-Kee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.3
    • /
    • pp.163-172
    • /
    • 2007
  • A seafloor curvature measurement method was developed to extract redundant topographic features from the multi-beam bathymetry data, and then applied to the data of abyssal plain area in the Pacific. Any seafloor might be modeled to a quadratic surface determined in a linear least squares sense, and its curvature could be derived from the eigen values related with quadratic model parameters. The curvature's magnitude as well as polarity showed distinct relationship with geometric characteristics of the seafloor like as ridge and valley. From the investigation of curvature's variation with the number of data in the quadratic surface, the optimal size of data aperture could be applied to real bathymetry data. The application to real data also required the determination of the accompanying threshold values to cope with corresponding topographic features. The calculation method of previous studies were reported to be sensitive to the background noise. The improved curvature measurement method, incorporating the sum of eigen values has reduced unwanted artifacts and enhanced ability to extract lineament features along strike direction. The result of application shows that the curvature measurement method is effective tool for the estimation of a possible mining area in the seamount free abyssal hill area.

An implementation of 2D/3D Complex Optical System and its Algorithm for High Speed, Precision Solder Paste Vision Inspection (솔더 페이스트의 고속, 고정밀 검사를 위한 이차원/삼차원 복합 광학계 및 알고리즘 구현)

  • 조상현;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.139-146
    • /
    • 2004
  • A 2D/3D complex optical system and its vision inspection algerian is proposed and implemented as a single probe system for high speed, precise vision inspection of the solder pastes. One pass un length labeling algorithm is proposed instead of the conventional two pass labeling algorithm for fast extraction of the 2D shape of the solder paste image from the recent line-scan camera as well as the conventional area-scan camera, and the optical probe path generation is also proposed for the efficient 2D/3D inspection. The Moire interferometry-based phase shift algerian and its optical system implementation is introduced, instead of the conventional laser slit-beam method, for the high precision 3D vision inspection. All of the time-critical algorithms are MMX SIMD parallel-coded for further speedup. The proposed system is implemented for simultaneous 2D/3D inspection of 10mm${\times}$10mm FOV with resolutions of 10 ${\mu}{\textrm}{m}$ for both x, y axis and 1 ${\mu}{\textrm}{m}$ for z axis. Experiments conducted on several nBs show that the 2D/3D inspection of an FOV, excluding an image capturing, results in high speed of about 0.011sec/0.01sec, respectively, after image capturing, with $\pm$1${\mu}{\textrm}{m}$ height accuracy.

THE EVALUATION OF THE PATIENTS TAKING CBCT IN DEPARTMENT OF PEDIATRIC DENTISTRY (소아치과에서 Cone beam형 전산화단층영상을 이용한 환자의 평가)

  • Jeon, Hye-Jin;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.249-256
    • /
    • 2012
  • Cone beam computed tomography (CBCT) has become widely available in recent years and is recognized as an important diagnostic tool for varies disease and condition of the orofacial structure. Clinician is easy to determine adequate treatment plan for pediatric patients by using CBCT. CBCT is used in Chonbuk National University Dental Hospital since 2005. This research presents clinical application of CBCT on patients visiting department of pediatric dentistry in Chonbuk National University Dental Hospital from Jan, 2005 to July, 2011. 1. Total number of patients taken CBCT is 252, and total number of area taken CBCT is 279. 2. An age group form 9 years to 12 years showing 53% was highest and percentage of 6~8 years showed 24%. 3. Chief complaints for CBCT taking are position and shape of impacted teeth (49.1%), mesiodens (19.4%), supernumerary teeth (7.9%), position and root canal shape of erupting teeth (7.2%), cyst (5.4%), inflammatory lesion (3.9%), odontoma (3.9%), tumor (2.2%), and et al. 4. Treatments are extraction (29.7%), orthodontic traction and leveling (24.0%), follow up (16.5%), refer to other professional part (11.5%), endodontic treatment (3.9%), surgical removal (2.9%), malsupialization (3.9%), enucleation (1.1%), and fail to follow up (5.0%), and et al.

The thickness of alveolar bone at the maxillary canine and premolar teeth in normal occlusion

  • Jin, Seong-Ho;Park, Jun-Beom;Kim, Namryang;Park, Seojin;Kim, Kyung Jae;Kim, Yoonji;Kook, Yoon-Ah;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.5
    • /
    • pp.173-178
    • /
    • 2012
  • Purpose: The main purpose of this study was to investigate bone thickness on the buccal and palatal aspects of the maxillary canine and premolars using cone-beam computed tomography (CBCT). The differences between left- and right-side measurements and between males and females were also analyzed. Methods: The sample consisted of 20 subjects (9 males and 11 females; mean age, $21.9{\pm}3.0$) selected from the normal occlusion sample data in the Department of Orthodontics, The Catholic University of Korea. The thickness of the buccal and palatal bone walls, perpendicular to the long axis of the root were evaluated at 3 mm and 5 mm apical to cemento-enamel junction (CEJ) and at root apex. Results: At the canines and first premolars regions, mean buccal bone thickness of at 3 mm and 5 mm apical to CEJ were less than 2 mm. In contrast, at the second premolar region, mean buccal bone thickness at 3 mm and 5 mm apical from CEJ were greater than 2 mm. Frequency of thick bone wall (${\geq}2mm$) increased from the canine to the second premolar. Conclusions: This result should be considered before tooth extraction and planning of rehabilitation in the canine and premolar area of maxilla. Careful preoperative analysis with CBCT may be beneficial to assess local risk factors and to achieve high predictability of success in implant therapy.