• Title/Summary/Keyword: Beam Tracking

Search Result 181, Processing Time 0.027 seconds

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.

A Novel Mobile Antenna for Ku-Band Satellite Communications

  • Park, Ung-Hee;Noh, Haeng-Sook;Son, Seong-Ho;Lee, Kyong-Hee;Jeon, Soon-Ik
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.243-249
    • /
    • 2005
  • A mobile antenna for multimedia communications with Ku-band geostationary satellite KOREASAT-3 and JSAT-2A is presented. The forward link of the satellite communication is 11.7 to 12.75 GHz, and the return link is 14.0 to 14.5 GHz. The mobile antenna is designed to be a stair structure using 24 active phased array elements in order to provide a low profile, and to be at a non-periodic array distance using the genetic algorithm. Also, the designed antenna uses the double beam forming method for stable satellite tracking. The fabricated mobile antenna is examined using various experiments to confirm its capability for practical application. From the measured results, the fabricated mobile antenna system is confirmed to have a good performance.

  • PDF

Frequency and Amplitude Control of Micro Resonant Sensors (마이크로 공진형 센서의 주파수 및 진폭 제어)

  • Park, Sung-Su
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.258-264
    • /
    • 2009
  • This paper presents two control algorithms for the frequency and amplitude of the resonator of a micro sensor. One algorithm excites the resonator at its a priori unknown resonant frequency, and the other algorithm alters the resonator dynamics to place the resonant frequency at a fixed frequency, chosen by the designer. Both algorithms maintain a specified amplitude of oscillations. The control system behavior is analyzed using an averaging method, and a quantitative criterion is provided for the selecting the control gain to achieve stability. Tracking and estimation accuracy of the natural frequency under the presence of measurement noise is also analyzed. The proposed control algorithms are applied to the MEMS dual-mass gyroscope without mechanical connecting beam between two proof-masses. Simulation results show the effectiveness of the proposed control algorithms which guarantee the proof-masses of the gyroscope to move in opposite directions with the same resonant frequency and oscillation amplitude.

3D Printed customized sports mouthguard (3D 프린터로 제작하는 마우스가드)

  • Ryu, Jae Jun;Lee, Soo Young
    • The Journal of the Korean dental association
    • /
    • v.58 no.11
    • /
    • pp.700-712
    • /
    • 2020
  • The conventional mouthguard fabrication process consists of elastomeric impression taking and followed gypsum model making is now into intraoral scanning and direct mouthguard 3D printing with an additive manufacturing process. Also, dental professionals can get various diagnostic data collection such as facial scans, cone-beam CT, jaw motion tracking, and intraoral scan data to superimpose them for making virtual patient datasets. To print mouthguards, dental CAD software allows dental professionals to design mouthguards with ease. This article shows how to make 3D printed mouthguard step by step.

  • PDF

Robust Position Control of a Single-Link Flexible Manipulator Using Sliding Mode and Piezofilm Actuator (슬라이딩모드와 압전필름 작동기를 이용한 단일링크 유연 머니퓰레이터의 강건위치제어)

  • 최승복
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1371-1381
    • /
    • 1995
  • A novel hybrid control scheme to actively control the endpoint position of a very flexible single-link manipulator is proposed. The control scheme consists of a motor mounted at the beam hub and a piezofilm actuator bonded to the surface of the flexible link. The control torque of the motor to produce a desired motion is firstly determined by employing the sliding mode control theory on the equation of motion of the rigid link having the same mass as that of the proposed flexible link. The torque is then applied to the flexible manipulator in order to activate the commanded motion. During the motion, undesirable oscillation is actively suppressed by applying a feedback control voltage to the piezofilm actuator. Consequently, the imposed desired position is accomplished. In order to demonstrate high control performances accrued from the proposed method, computer simulations are undertaken by treating both regulating and tracking control problems.

Pressure Control of a Piezoactuator-Driven Pneumatic Valve System (압전 작동기로 구동 되는 공압 밸브의 압력제어)

  • Jo, Myeong-Su;Yu, Jung-Gyu;Choe, Seung-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.399-405
    • /
    • 2002
  • This paper proposes a new type of piezoactuator-driven valve system. The piezoceramic actuator bonded to both sides of a flexible beam surface makes a movement required to control the pressure at the flapper-nozzle of a pneumatic valve system. After establishing a dynamic model, an appropriate size of the valve system is designed and manufactured. Subsequently, a robust H$_{\infty}$ control algorithm is formulated in order to achieve accurate tracking control of the desired pressure. The controller is experimentally realized and control performance for the sinusoidal pressure trajectory is presented in time domain. The control bandwidth of the valve system, which directly represents the fastness, is also evaluated in the frequency domain.

Development of New Focus Control Model for Optical Disk Drives (광디스크 드라이브의 새로운 포커스 제어모델 개발)

  • Jee, Jung-Geun;Chang, Young-Bae;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.1004-1009
    • /
    • 2002
  • There are four servo systems in a DVD drive such as a focus servo system, a tracking servo system, a sled servo system and a spindle servo system. Focus servo system maintains relative distance between lens and disk. In this paper, two plant models for the focus servo system will be presented. One of them is conventional and the other is newly developed. Focus error signal between lens and disk is detected using LDV 2 beam method. The system is observable and all states are estimated. Full states feedback controller and minimum order observed are designed using those states. Impulse responses are simulated. And experiment is performed to compare with responses of conventional model.

  • PDF

5ft S-Band TT&C Antenna Test

  • Ahn Sang-il;Park Dong-Chul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.467-470
    • /
    • 2004
  • In early 2004, KARI developed 5ft S-Band TT&C antenna for especially KOMPSAT-2 operation in LEOP phase. This paper shows system features of 5ft S-Band antenna and its test result with KOMPSAT-l. Tracking test, command uplink test and telemetry downlink test were performed. Through tests, 5ft antenna was verified to be operational in uplink and downlink with KOMPSAT series. Due to its inherent wide 3dB beam-width of about 7deg at S-Band, this antenna system can be used very effectively even though orbital information is less accurate like LEOP and spacecraft safe mode.

  • PDF

Fabrication of He-Ne ellipsometer and in-situ measurement of effective density variation of $TiO_2$thin films (보급형 He-Ne 타원해석기의 제작과 $TiO_2$ 박막 유효밀도 변화의 in-situ 측정)

  • 김상준;방현용;김상열
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.432-437
    • /
    • 1999
  • We have fabricated an in situ ellipsometer operating at He-Ne wavelength. It can be applied to the real-time, in-situ tracking of the ellisometric change which occurs during various sample treatments. As a rotating analyzer type, all optical elements and related parts are designed to share a common hollow-axis configuration, and hence the ellipsometer is compact in shape and simple in design. It is mountable on the spare ports of vacuum chamber with ease. Using this ellipsometer, we observed the effective density variation of previously grown $TiO_2$ thin films by using electron beam evaporation. The packing density of the as-grown film was 82%. When exposed to atomsphere, the micro-void of the film was filled with water vapor. This water-filled $TiO_2$ thin film was subject to heating/cooling cycles in vacuum and the ellipsometric variation versus temperature and cycling number was measured in real time using this in situ He-Ne ellipsometer.

  • PDF

Degradation Analysis of User Terminal EIRP and G/T due to Station-Keeping Variation of Stratospheric Platform

  • Ku, Bon-Jun;Ahn, Do-Seob;Baek, Dong-Cheol;Park, Kwang-Ryang;Lee, Seong-Pal
    • ETRI Journal
    • /
    • v.22 no.1
    • /
    • pp.12-19
    • /
    • 2000
  • Wireless communication systems using airship have been proposed in worldwide. The airship will be located at the stratosphere about $20{\sim}23\;km$ above the sea level. The position of airship will vary within the station keeping range with time due to the drag of the wind in the stratosphere. When the earth station antenna has a high gain without the tracking function, the antenna performance may be degraded by a small variation of the airship. This means that variation of airship location could result in serious degradation of the system performance. In this paper, degradation in earth station's Equivalent Isotropic Radiated Power (EIRP) and Gain to noise Temperature ratio (G/T) due to the stratospheric platform movements has been derived by calculating the deviation angle of the main beam directions between the earth station and the platform antenna. In this case, the antenna of the earth station has been assumed circular and/or patch array antennas.

  • PDF