• 제목/요약/키워드: Beam Head

검색결과 360건 처리시간 0.023초

액체로켓 연소기용 Inconel 718 주조 및 단조 합금의 전자빔 용접부 미세조직 및 극저온 특성 (A Study on Microstructures and Cryogenic Mechanical Properties of Electron Beam Welds between Cast and Forged Inconel 718 Superalloys for Liquid Rocket Combustion Head)

  • 홍현욱;배상현;권순일;이재현;도정현;최백규;김인수;조창용
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.50-57
    • /
    • 2013
  • Characterization of microstructures and cryogenic mechanical properties of electro beam (EB) welds between cast and forged Inconel 718 superalloys has been investigated. Optimal EBW condition was found in the beam current range of 36~39 mA with the constant travel speed of 12 mm/s and arc voltage of 120 kV for 10 mm-thick specimens. Electron beam current lower than 25 mA caused to occur the liquation microfissuring in cast-side heat affected zone (HAZ) of EB welds. The HAZ liquation microfissure was found on the liquated grain boundaries with resolidified ${\gamma}/Laves$ and ${\gamma}/NbC$ eutectic constituents. EBW produced welds showing a fine dendritic structure with relatively discrete Laves phase due to fast cooling rate. After post weld aging treatment, blocky Laves phase and formation of ${\gamma}^{\prime}+{\gamma}^{{\prime}{\prime}}$ strengtheners were observed. Presence of primary strengthener and coarse Laves particles in PWHT weld may cause to reduce micro-plastic zone ahead of a crack, leading to a significant decrease in Charpy impact toughness at $-196^{\circ}C$. Fracture initiation and propagation induced by Charpy impact testing were discussed in terms of the dislocation structures ahead of crack arisen from the fractured Laves phase.

Economic construction management of composite beam using the head stud shear connector with encased cold-formed steel built-up fix beam via efficient computer simulation

  • Yin, Jinzhao;Tong, Huizhi;Gholizadeh, Morteza;Zandi, Yousef;Selmi, Abdellatif;Roco-Videla, Angel;Issakhov, Alibek
    • Advances in concrete construction
    • /
    • 제11권5호
    • /
    • pp.429-445
    • /
    • 2021
  • With regard to economic efficiency, composite fix beams are widely used to pass longitudinal shear forces across the interface. The current knowledge of the composite beam load-slip activity and shear capability are restricted to data from measurements of push-off. Modelling and analysis of the composite beams based on Euro-code 4 regarding to shear, bending, and deflection under differing loads were carried out using Finite Element through an efficient computer simulation and the final loading and sections capacity based on the failure modes was analysed. In bending, the section potential was increased by an improvement of the strength in both steel and concrete, but the flexural and compressive resistance growth is very weak (3.2% 3.1% and 3.0%), while the strength of the concrete has increased respectively from 25 N/mm2 to 30, 35, and 40 N/mm2 compared to the increment of steel strength by 27% and 21% when it was raised from 275 to 355 and 460 N/mm2, respectively. It was found that the final flexural load capacity of fix beams was declined with increase in the fix beam span for both three steel strength. The shear capacity of sections was remained unchanged at constant steel strength and different length, but raised with final yield strength increment of steel sections by 29%, and 67% when it was raised from 275 N/mm2 to 355 N/mm2 and 460 N/mm2, respectively.

Quasi-optical design and analysis of a remote steering launcher for CFETR ECRH system

  • Zhang Chao;Xiaojie Wang;Dajun Wu;Yunying Tang;Hanlin Wang;Dingzhen Li;Fukun Liu;Muquan Wu;Peiguang Yan;Xiang Gao;Jiangang Li
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1619-1626
    • /
    • 2024
  • In order to optimize the operational safety and reliability of the upper launcher for the CFETR ECRH system, a design of the launcher for NTM control based on the remote steering concept is currently being carried out for comparison with the front steering equivalent. This paper presents the layout design and analysis of the quasi-optical system in the remote steering launcher. A 3D visual quasi-optical design tool has been developed for the quasi-optical system, which can parameterize modeling, perform general astigmatic beam calculation and show the accurate beam propagation path in the upper port. Three identical sets of quasi-optical modules are arranged in the launcher, and each one consists of two fixed double-curvature focusing mirrors, which focus and reflect the steering beams (- 12°-12°) from two square corrugated waveguides. The beam characteristics at the resonance layer are described, and the average beam radius is < 100 mm. The peak head loads on the surfaces of the two fixed mirrors are 1.63 MW/m2 and 1.52 MW/m2. The position and size of the beam channel in the blanket are obtained, and the opening apertures on the launcher-facing and plasma-facing sides of the blanket module are 0.54 m2 and 0.4 m2, respectively.

전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질 (Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations)

  • 조평곤;김유현;최종학;이기열;김형철;김장섭;신동철;이성현;이준협;신귀순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.453-460
    • /
    • 2009
  • 슬라이스 두께(slice thickness)와 선속시준(beam collimation, BC)의 변화에 따른 CT gantry aperture 내의 선량 분포와 영상의 질을 알아보고자 하였다. CT장치로는 64-slice MDCT 스캐너(Brilliance 64, Philips, Cleveland, USA)를 사용하였다. 피사체가 없는 경우(air scan)의 선량측정을 위해 CT용 전리함을 gantry aperture내의 회전중심점(isocenter)과 12시, 3시, 6시, 9시 방향에서 회전중심점으로부터 5 cm 간격으로 30 cm까지 BC를 변화시키면서 각각 측정 하였다. 또한 5개의 구멍(팬텀의 중심과 12시, 3시, 6시, 9시 방향)으로 구성된 CT head and body dose phantom을 gantry aperture 내에 위치시키고 각 지점에서 선량을 측정하였다. Gantry aperture 내 피사체의 위치변화에 대한 영상의 노이즈를 비교하기 위해서 AAPM CT용 팬텀의 물통을 회전중심점과 12시 방향으로 5 cm와 10 cm 이동시킨 후 BC를 변화시키면서 스캔한 후 팬텀의 중심과 12시, 3시, 6시, 9시 방향의 지점에서 노이즈를 측정하였다. 이 중에서 몇 군데의 위치는 영상 영역에서 벗어나서 측정 할 수가 없었다. 이때 노이즈 측정을 위해서 영상재구성의 슬라이스 두께는 5 mm로 하였다. 측정한 결과 다음과 같은 결론을 얻었다: 첫째, CTDIw는 회전중심점으로부터 멀어질수록, BC가 넓어질수록 감소하였다. 둘째, BC의 넓이가 비슷한 경우의 CTDIw는 거의 유사한 값을 보였다. 즉, CTDIw는 검출기 배열의 수나 화소의 크기 보다는 전체적인 BC의 넓이에 의존하고 있음을 알 수 있었다. 셋째, air scan과 phantom scan 경우 모두에서 CTDIw는 BC가 증가될수록 감소하였다. 그러나 air scan의 경우보다 head phantom scan 시 약 30%, body phantom scan 시 약 52% 정도 CTDIw의 값이 감소하였다. 넷째, BC와 팬텀의 위치 변화에 따른 노이즈 값은 $2{\times}0.5\;mm$의 BC을 제외하고는 head phantom scan한 경우 3.9~5.9, body phantom scan한 경우 5.3~7.4로 나타나, BC와 팬텀의 위치변화에 따라서 큰 차이가 없었다. 따라서 피사체의 위치가 gantry aperture 내 SFOV(scan field of view)에 포함될 경우 회전중심점에 정확하게 위치시키지 않아도 영상의 질에는 많은 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

Reduction of Patient Dose in Radiation Therapy for the Brain Tumors by Using 2-Dimensional Vertex or Oblique Vertex Beam Technique

  • Kim, Il-Han;Chie, Eui-Kyu;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • 제28권3호
    • /
    • pp.225-231
    • /
    • 2003
  • Up-front irradiation technique as 3-dimensional conformation, or intensity modulation has kept large proportion of brain tumors from being complicated with acute radiation reactions in the normal tissue during or shortly after radiotherapy. For years, we've cannot help but counting on 2-D vertex beam technique to reduce acute reactions in the brain tumor patients because we're not equipped with 3-dimensional planning system. We analyzed its advantages and limitations in the clinical application. From 1998 to 2001, vertex or oblique vertex beams were applied to 35 patients with primary brain tumor and 25 among them were eligible for this analysis. Vertex(V) plans were optimized on the reconstructed coronal planes. As the control, we took the bilateral opposed techniques(BL) otherwise being applied. We compared the volumes included in 105% to 50% isodose lines of each plan. We also measured the radiation dose at various extracranial sites with TLD. With vertex techniques, we reduced the irradiated volumes of contralateral hemisphere and prevented middle ear effusion at contralateral side. But the low dose volume increased outside 100%; the ratio of V to BL in irradiated volume included in 100%, 80%, 50% was 0.55+/-0.10, 0.61+/-0.10, and 1.22+/-0.21, respectively. The hot area within 100% isodose line almost disappeared with vertex plan; the ratio of V to BL in irradiated volume included in 103%, 105%, 108% was 0.14+/-0.14, 0.05./-0.17, 0.00, respectively. The dose distribution within 100% isodose line became more homogeneous; the ratio of volume included in 103% and 105% to 100% was 0.62+/-0.14 and 0.26+/-0.16 in BL whereas was 0.16+/-0.16 and 0.02+/-0.04 in V. With the vertex techniques, extracranial dose increased up to $1{\sim}3%$ of maximum dose in the head and neck region except submandibular area where dose ranged 1 to 21%. From this data, vertex beam technique was quite effective in reduction of unnecessary irradiation to the contralateral hemispheres, integral dose, obtaining dose homogeneity in the clinical target. But it was associated with volume increment of low dose area in the brain and irradiation toward the head and neck region otherwise being not irradiated at all. Thus, this 2-D vertex technique can be a useful quasi-conformal method before getting 3-D apparatus.

선미식(船尾式) 트롤선(船)의 해양항행중(海洋航行中) 파고(波高)와 선속(船速)에 따른 선체(船体) 동요특성(動搖特性) (The Characteristics of Motion Response of Stern Trawlers according to the Wave Height and the Ship's Speed in the Sea)

  • 강일권;박병수
    • 수산해양교육연구
    • /
    • 제12권2호
    • /
    • pp.199-212
    • /
    • 2000
  • It is very important to investigate the hull response of a fishing vessel in the sea to ensure the safe navigation and fishing operation in rough sea by preserving excellent sea keeping qualities. For this purpose, the author measured various responses of three stem trawlers in waves using real sea experimental measuring system. The author analyzed the experimental data using the statistical and spectral analyzing method to get the characteristics of the motion responses of the vessels according to the wave height and the ship's speed. The results obtained can be summarized as follows ; (1) Rather higher response of the pitch motion due to the wave height appeared in the head sea and the bow sea than any other wave direction without relevance to ship's size. In case of the roll motion, the beam sea and the quartering sea have a high response value. The period of peak of the pitch motion and the roll motion according to the wave height in each vessel has almost same value respectively. (2) The change of response of the pitch motions deeply depend on the ship's speed in the head sea and the bow sea, but not in the other wave direction. (3) The change of response of the roll motions in the beam sea, the quartering sea and the following sea are affected by the influence of the ship's speed in 5k't to 8k't, but not related to the ship's speed in out of that range.

  • PDF

어류 체장의 자동 식별을 위한 어종별, 체장별 및 주파수별 음향 반사 강도의 데이터 뱅크 구축 (Construction of a Data Bank for Acoustic Target Strength with Fish Species, Length and Acoustic Frequency for Measuring Fish Size Distribution)

  • 이대재;신형일
    • 한국수산과학회지
    • /
    • 제38권4호
    • /
    • pp.265-275
    • /
    • 2005
  • A prerequisite for deriving the abundance estimates from acoustic surveys for commercially important fish species is the identification of target strength measurements for selected fish species. In relation to these needs, the goal of this study was to construct a data bank for converting the acoustic measurements of target strength to biological estimates of fish length and to simultaneously obtain the target strength-fish length relationship. Laboratory measurements of target strength on 15 commercially important fish species were carried out at five frequencies of 50, 70, 75, 120 and 200 kHz by single and split beam methods under the controlled conditions of the fresh and the sea water tanks with the 389 samples of dead and live fishes. The target strength pattern on individual fish of each species was measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down aspect) to $+45^{\circ}$ (head up aspect) in $0.2^{\circ}$ intervals, and the averaged target strength was estimated by assuming the tilt angle distribution as N $(-5.0^{\circ},\;15.0^{\circ})$. The TS to fish length relationship for each species was independently derived by a least-squares fitting procedure. Also, a linear regression analysis for all species was performed to reduce the data to a set of empirical equations showing the variation of target strength to a fish length, wavelength and fish species. For four of the frequencies (50, 75, 120 and 200 kHz), an empirical model for fish target strength (TS, dB) averaged over the dorsal sapect of 602 fishes of 10 species and which spans the fish length (L, m) to wavelength (\Lambda,\;m)$ ratio between 5 and 73 was derived: $TS=19.44\;Log(L)+0.56\;Log(\Lambda)-30.9,\;(r^2=0.53)$.

한국 연근해에서 어획된 주요 12어종의 75 kHz에 대한 음향 반사 강도의 체장 의존성 (Fish length dependence of acoustic target strength for 12 dominant fish species caught in the Korean waters at 75 kHz)

  • 이대재
    • 수산해양기술연구
    • /
    • 제41권4호
    • /
    • pp.296-305
    • /
    • 2005
  • Acoustic target strength (TS) of 12 commercially important fish species caught in the Korean waters had been investigated and their results were presented. Laboratory measurements of target strength on 12 dominant fish species were carried out at a frequencies of 75 kHz by single beam method under the controlled condition of the water tank with the 241 samples of dead and live fishes. The target strength pattern on individual fish of each species was measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down aspect) to $45^{\circ}$ (head up aspect) in $0.2^{\circ}$ intervals, and the averaged target strength was estimated by assuming the tilt angle distribution as N ($-5.0^{\circ}$, $^15.0{\circ}$). The 75 to fish length relationship for each species was independently derived by a least - squares fitting procedure. Also, a linear regression analysis for all species was performed to reduce the data to a set of empirical equations showing the variation of target strength to fish length and fish species. An empirical model for fish target strength(TS, dB) averaged over the dorsal aspect of 158 fishes of 7 species and which spans the fish length(L, m) to wavelength(${\lambda}$, m) ratio between 6.2 and 21.3 was derived: TS: 27.03 Log(L)-7.7Log(${\kanbda}$)-17.21, ($r^2$=0.59).

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • 한국임상수의학회지
    • /
    • 제41권3호
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

Orthognathic surgery with removal of lipoma in the asymmetric mandibular prognathism of a patient with a mandibular bone defect due to intramuscular lipoma on the medial aspect of the ramus: a case report

  • Yoon Ju Nam;Min Seong Kang;Jung Han Lee;Bok Joo Kim;Jung Han Kim;Chul Hoon Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제50권4호
    • /
    • pp.235-240
    • /
    • 2024
  • Lipomas, the most common soft-tissue mesenchymal neoplasms in adults, are characterized by the proliferation of mature white adipocytes without cytologic atypia. Lipomas are rarely observed in the head and neck region. We present a case of resection and orthognathic surgical removal of an intramuscular lipoma of the mandible with involvement of the mandibular ramus and condylar head and neck. An 18-year-old female patient was referred to our hospital for orthognathic surgery for the management of facial asymmetry and mandibular prognathism. The patient did not present with facial swelling, pain, or temporomandibular dysfunction; however, on radiographic examination, including cone-beam computed tomography and magnetic resonance imaging, an infiltrative fatty lesion was observed in the masticator space inside the right mandible, and the adjacent mandible exhibited bone thinning and deformity. Resection of the lipoma was performed along with orthognathic surgery, including a Le Fort I osteotomy for the maxilla and bilateral sagittal split ramus osteotomy (BSSRO). In this case, because the ramus was split using BSSRO, accessing the lipoma intraorally was easy. Consequently, aesthetic scarring was avoided, and no complications, such as unfavorable splitting or pathologic fracture, occurred. Although recurrence has not been observed about 1 year, long-term follow-up should be performed.