• Title/Summary/Keyword: Beam Factor

Search Result 1,017, Processing Time 0.034 seconds

Shear Performance of Post and Beam Construction by Pre-Cut Process (프리컷 방식을 적용한 기둥-보 공법의 수평전단내력)

  • Hwang, Kweonhwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1-12
    • /
    • 2007
  • For the purpose of effective utilization of domestic second-grown larch as structural members, post and beam construction applying traditional construction to Japanese larch glulam members was adopted with processing by machine pre-cut method. In general, horizontal shear test by KS F 2154 is conducted to assess the horizontal shear properties of the wooden structure by post and beam construction. The frame was consisted of post and beam member with appropriate fasteners, and members have their own processed parts (notch, hole, etc.) that can be well-connected each other. The shear wall was consisted of the frame with screw-nail sheathed panel (OSB). The results of horizontal shear loading tests without vertical loads conducted on the frame and the shear wall structures, the maximum strengths were about 1.9 kN/m and about 9.7 kN/m, the shear rigidities were about 167 kN/rad, 8198 kN/rad, respectively. The strength proportion of the frame specimen was about 20% of the wall's and about 2% in initial stiffness. Nail failures are remarkable on the shear wall specimen with punching shears and shear failures. The shear load factor for the shear wall specimen by the method of Architectural Institute of Japan was 1.5, which was obtained by the bi-linear method. Loading method should be considered to obtain smooth load-deformation relationship. For the better shear performance of the structures, column base and post and beam connections and sheathed panel should be further examined as well.

Effect of Hydride Reorientation on Delayed Hydride Cracking In Zr-2.5Nb Tubes

  • Yun Yeo Bum;Kim Young Suk;Im Kyung Soo;Cheong Yong Moo;Kim Sung Soo
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.529-536
    • /
    • 2003
  • The objective of this study is to investigate the reorientation of hydrides with applied stress intensity factor, the peak temperature and the time when to apply the stress intensity factor in a Zr-2.5Nb pressure tube during its thermal cycle treatment. Cantilever beam (CB) specimens with a notch of 0.5 mm in depth made from the Zr-2.5Nb tube were subjected to electrolytic hydrogen charging to contain 60 ppm H and then to a thermal cycle involving heating to the peak temperature of either 310 or $380^{\circ}C$, holding there for 50 h and then cooling to the test temperature of $250^{\circ}C$. The stress intensity factor of either 6.13 or $18.4\;MPa\sqrt{m}$ was applied at the beginning of the thermal cycle, at the end of the hold at the peak temperatures and after cooling to the test temperature, respectively. The reorientation of hydrides in the Zr-2.5Nb tube was enhanced with the increased peak temperature and applied stress intensity factor. Furthermore, when the CB specimens were subjected to $18.4\;MPa\sqrt{m}$ from the beginning of the thermal cycle, the reoriented hydrides occurred almost all over the Zr-2.5Nb tube, surprisingly suppressing the growth of a DHC crack. In contrast, when the CB specimens were subjected to the stress intensity factor at the test temperature, little reorientation of hydrides was observed except the notch region, leading the Zr-2.5Nb to grow a large DHC crack. Based on the correlation between the reorientation of hydrides and the DHC crack growth, a governing factor for DHC is discussed along with the feasibility of the Kim's DHC model.

Development of Schottky Diode for THz Applications using Heterogeneous Resist Patterning (이종 레지스트 패터닝을 이용한 테라헤르츠용 쇼트키 다이오드 개발)

  • Han, Min;Choi, Seok-Gyu;Lee, Sang-Jin;Baek, Tae-Jong;Ko, Dong-Sik;Kim, Jung-Il;Kim, Geun-Ju;Jeon, Seok-Gy;Yoon, Jin-Seob;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.8
    • /
    • pp.47-54
    • /
    • 2012
  • In this paper, we have fabricated the Schottky diode for THz applications by heterogeneous resist patterning method. The Schottky diode was developed using electron beam lithography and photolithography to connect the anode and the anode pad for a simple process. The measured performance of developed Schottky diode are $11.2{\Omega}$ of series resistance, 25.96 fF of junction capacitance, 1.25 of ideality factor and 547.6 GHz of cut-off frequency.

Study on Polarization Characteristics of Optical Device and Improvement of Measurement Precision of Normal Incidence Ellipsometer for Measuring Optical Anisotropy of a Micro Spot (미소면적 광학이방성 정밀 측정을 위한 수직반사형 타원계의 광소자 편광특성 및 측정정밀도 향상 연구)

  • Lyum, Kyoung Hun;Park, Sang Uk;Seo, Young Jin;Lee, Min Ho;Kim, Woong Ki;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.274-280
    • /
    • 2012
  • A normal incidence ellipsometer is fabricated to measure the optical anisotropy of a small spot whose diameter is less than $8.0{\mu}m$, by adding a beam splitter and a prism to the conventional rotating analyzer type ellipsometer. The polarizing actions of the added optical components are calibrated to improve the accuracy of the anisotropy measurement. The standard deviation of the optical anisotropy factor decreased to 0.00083, and the variation of the optical anisotropy factor of rutile versus sample azimuth angle variation also decreased to 0.015, after adoption of a non-polarizing beam splitter and a quarter wavelength phase retarder, followed by removal of the optical fiber and a careful choice of measurement wavelength.

Design and Fabrication of Base Station Antenna for ETCS based on DSRC (DSRC 기반의 ETCS 기지국 안테나 설계 및 제작)

  • Ko Jin-Hyun;Kim Nam-Ki;Ha Jae-Kwon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.75-83
    • /
    • 2004
  • This paper describes the design, fabrication, and measurement of a low side lobe antenna for RSE base station of the ETCS which is one of the ITS services. The antenna is installed on the gantry of road side and provides the wireless communication lint between vehicles and RSE. The required characteristics of ETCS base station antenna are low sidelobe and specific beam pattern by the road and install environment and installed place of OBU. To minimize the affects of multipath signal by reflection, Circular polarization is required. To get low sidelobe of antenna, array configuration and weighting factor by Taylor distribution in radiator elements are applied. The measured results of fabricated antenna are as follows; return loss of 130MHz by -10dB, an axial ratio of 2.6dB, and a gain of 17dBi. It is found that the measured beam patterns are similar to design results.

  • PDF

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.

Stress Measurement around a Circular Role in a Cantilever Beam under Bending Moment Using Strain Gage and Reflective Photoelasticity (스트레인 게이지와 반사형 광탄성법을 이용한 굽힘을 받는 외팔보 시편 구멍 주위의 응력측정)

  • Baek, Tae-Hyun;Park, Tae-Geun;Yang, Min-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.329-335
    • /
    • 2006
  • It is necessary to study on the stress concentration experimentally, which is the main reason to avoid mechanical dilapidation and failure, when designing a mechanical structure. Stress concentration factor of a specimen of cantilever beam with a circular hole in the center was measured using both strain gage and photoelastic methods in this paper. In strain-gage measurement, three strain gages along the line near a hole of the specimen were installed and maximum strain was extrapolated from three measurements. In photoelastic measurement, two methods were employed. First, the Babinet-Soleil compensation method was used to measure the maximum strain. Secondly, photoelastic 4-step phase shilling method was applied to observe the strain distribution around the hole. Measurements obtained by different experiments were comparable within the range of experimental error.

Treatment Outcome with Brachytherapy for Recurrent Nasopharyngeal Carcinoma

  • Cheah, Soon Keat;Lau, Fen Nee;Yusof, Mastura Md;Phua, Vincent Chee Ee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6513-6518
    • /
    • 2013
  • Background: To evaluate the treatment outcome and major late complications of all patients with recurrent nasopharyngeal carcinoma (NPC) treated with intracavitary brachytherapy (ICBT) in Hospital Kuala Lumpur. Materials and Methods: This retrospective study was conducted at the Department of Radiotherapy and Oncology, Hospital Kuala Lumpur, Malaysia. All patients with histologically confirmed recurrent NPC in the absence of distant metastasis treated in the period 1997-2010 were included in this study. These patients were treated with ICBT alone or in combination with external beam radiotherapy (EBRT). Treatment outcomes measured were local recurrence free survival (LRFS), disease free survival (DFS) and overall survival (OS). Results: Thirty three patients were eligible for this study. The median age at recurrence was 56 years with a median time to initial local recurrence of 27 months. Majority of patients were staged as rT1-2 (94%) or rN0 (82%). The proportion of patients categorised as stage III-IV at first local recurrence was only 9%. Twenty one patients received a combination of ICBT and external beam radiotherapy while 12 patients were treated with ICBT alone. Median interval of recurrence post re-irradiation was 32 months (range: 4-110 months). The median LRFS, DFS and OS were 30 months, 29 months and 36 months respectively. The 5 year LRFS, DFS and OS were 44.7%, 38.8% and 28.1% respectively. The N stage at recurrence was found to be a significant prognostic factor for LRFS and DFS after multivariate analysis. Major late complications occurred in 34.9% of our patients. Conclusions: Our study shows ICBT was associated with a reasonable long term outcome in salvaging recurrent NPC although major complications remained a significant problem. The N stage at recurrence was a significant prognostic factor for both LRFS and DFS.

Fracture Toughness of Glass Fiber Reinforced Laminated Timbers (유리섬유 보강적층재의 파괴인성 특성)

  • Kim, Keon-ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.861-867
    • /
    • 2015
  • The Compact Tension (CT) type test was performed in order to evaluate the fracture toughness performance of glass fiber-reinforced laminated timber. Glass fiber textile and sheet Glass fiber reinforced plastic were used as reinforcement. The reinforced laminated timber was formed by inserting and laminating the reinforcement between laminated woods. Compact tension samples are produced under ASTM D5045. The sample length was determined by taking account of the end distance of 7D, and bolt holes (12 mm, 16 mm, 20 mm) had been made at the end of artificial notches in advance. The fracture toughness load of sheet fiberglass reinforced plastic reinforced laminated timber was increased 33 % in comparison to unreinforced laminated timber while the glass fiber textile reinforced laminated timber was increased 152 %. According to Double Cantilever Beam theory, the stress intensity factor was 1.08~1.38 for sheet glass fiber reinforced plastic reinforced laminated timber and 1.38~1.86 for glass fiber textile reinforced laminated timber, respectively. That was because, for the glass fiber textile reinforced laminated timber, the fiber array direction of glass fiber and laminated wood orthogonal to each other suppressed the split propagation in the wood.

Dose Attenuation in the Mid-Cranial Fossa with 6 MV Photon Beam Irradiations (6 MV X-선 조사시 중두개와에서의 선량감쇠)

  • Park, Jeong-Ho;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.8 no.1
    • /
    • pp.125-131
    • /
    • 1990
  • In X-ray irradiation, dose distribution depends on multiple parameters, one of them being tissue inhomogeneity to change the dose significantly. considerable dose attenuation through the mid-cranial fossa is expected because of various bony structures in it. Dose distribution around the mid-cranial fossa, following irradiation with 6 MV photon beam, was measured with LiF TLD micro-rod, and compared with the expected dose inthe same sites. In our calculation with $C_f$(correction factor), the expected dose attenuation revealed about $3.74\%$ per 1 cm thickness of bone tissue. And the differences between the expected dose with correction for bone tissue and the measured dose by TLD was small, agreeing within an average variation of $\pm0.21\%$.

  • PDF