• 제목/요약/키워드: Beam Expansion

검색결과 224건 처리시간 0.027초

Design and Performance Evaluation of Extension-Type Actuators with a Displacement Amplification Mechanism Based on Chevron Beam

  • Jo, Yehrin;Lee, Euntaek;Kim, Yongdae
    • Journal of Aerospace System Engineering
    • /
    • 제15권6호
    • /
    • pp.1-9
    • /
    • 2021
  • In this study, a new design of an extension-type actuator (ExACT) is proposed based on a chevron structure with displacement amplification mechanisms by local heating. ExACT comprises diamond-shaped displacement amplification structures (DASs) containing axially oriented V-shaped chevron beams, a support bar that restricts lateral heat deformation, and a loading slot for thin-film heaters. On heating the thin film heater, the diamond-shaped DASs undergo thermal expansion. However, lateral expansion is restricted by the support bar, leading to displacement amplification in the axial direction. The performance parameters of ExACT such as temperature distribution and extended displacement is calculated using thermo-mechanical analysis methods with the finite element method (FEM) tool. Subsequently, the ExACTs are fabricated using a polymer-based 3D printer capable of reproducing complex structures, and the performance of ExACTs is evaluated under various temperature conditions. Finally, the performance evaluation results were compared with those of the FEM analysis.

Effectiveness of low-level laser therapy in facilitating maxillary expansion using bone-borne hyrax expander: A randomized clinical trial

  • Abdelwassie, Sara Hassan;Kaddah, Mohammed Amgad;El-Dakroury, Amr Emad;El-Boghdady, Dalia;Abd El-Ghafour, Mohamed;Seifeldin, Nouran Fouad
    • The korean journal of orthodontics
    • /
    • 제52권6호
    • /
    • pp.399-411
    • /
    • 2022
  • Objective: The objective of this randomized clinical trial was to study the skeletal and dental effects of low-level laser therapy (LLLT) along with a miniscrew-assisted expander (Hyrax) after six months of retention. Methods: After sequence generation, concealed allocation, and implementation, 24 female patients were randomly divided (1:1) into two-groups: bone-borne rapid palatal expansion (BBE) without LLLT (n = 12) and BBE with LLLT (n = 12). Eligibility criteria included female patients aged 10-13 years old with bilateral posterior crossbites. Intraoral and extraoral photographs, cone-beam computed tomography images, and digital study models were obtained before expansion and six months after retention. The 7 mm Hyrax appliance was anchored to four palatal mini-screws, which were activated twice daily for 15 days, then locked and kept in place as a retainer. LLLT was performed in the laser group during expansion and retention, according to the guidelines provided. Results: The records of 24 patients were analyzed. According to the post-retention measurements, both groups showed a significant increase in nasal and maxillary widths and total facial height. In the laser group, the Sella-Nasion-Point A and Point A-Nasion-Point B angles and the interpremolar apical distance were significantly increased. Conclusions: Within the limitations of this study, the results suggest that the parameters and protocol of LLLT do not clinically affect the efficiency of BBE in prepubertal and pubertal patients.

Fabrication of Grating Structures and Their Applications in Integrated Optics (집적광학용 격자구조의 제작과 응용)

  • Lee, Seong-Jae;Song, Jae-Won;Sin, Sang-Yeong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제21권3호
    • /
    • pp.39-45
    • /
    • 1984
  • Submicron gratings are fabricated holographically on thin film single mode and multimode waveguides. Thin film waveguides are made by spin-coating polyurethane solution on the substrates of microscope slide glass and Corning 7059 glass. In order to characterize thin film waveguides, the refract사e index and the thickness of thin films are measured by using the m-line spectroscopy. The fabricated gratings are tested as a grating coupler, a mode converter, and a beam splitter. Also chirped gratings are fabricated to observe beam expansion phenomena and thus the possibility of the wavelength demultiplexing.

  • PDF

A Study on the Design of 16-Channel AWG Wavelength Division Multiplexer for Super High-Speed Optical Communication (초고속 광통신을 위한 16-Channel AWG 파장다중화기의 설계에 관한 연구)

  • Cho, Myung-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제54권3호
    • /
    • pp.148-154
    • /
    • 2005
  • Various methods for analyze optical components which are necessary before the fabrication of optical circuit component and as its applications, designing method of Wavelength Division Multiplexer(WDM) filter using arrayed-waveguide grating(AWG) is paper. In the case of analyzing uniform optical waveguide, effective index method(EIM), harmonic expansion method are used, and in the case of non-uniform optical waveguide, beam propagation method(BPM) are used. In this paper, to use arrayed-waveguide grating as WDM filter of centered wavelength of $1.55{\mu}m$ and wavelength spacing of 0.8nm, all of the parameter of AWG is calculated by the HEM and the BPM using EIM. As a result of calculation, free spectral range is 12.8nm, focal length $9336.55{\mu}m$, path difference $129.36{\mu}m$ and the number of slab waveguide 91 when the distance of core center to center on row land circle is $20{\mu}m$.

Arrested pneumatization of the sphenoid sinus mimicking intraosseous lesions of the skull base

  • Jalali, Elnaz;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.67-72
    • /
    • 2015
  • Arrested pneumatization of the sphenoid sinus is a developmental variant that is not always well recognized and is often confused with other pathologies associated with the skull base. This report describes the case of a patient referred for cone-beam computed tomography (CBCT) imaging for dental implant therapy. CBCT demonstrated a well-defined incidental lesion in the left sphenoid sinus with soft tissue-like density and sclerotic borders with internal curvilinear opacifications. The differential diagnoses included intraosseous lipoma, arrested pneumatization of the sphenoid sinus, chondrosarcoma, chondroid chordoma, and ossifying fibroma. The radiographic diagnosis of arrested pneumatization was based on the location of the lesion, its well-defined nature, the presence of internal opacifications, and lack of expansion. Gray-scale CBCT imaging of the area demonstrated values similar to fatty tissue. This case highlighted the fact that benign developmental variants associated with the skull base share similar radiographic features with more serious pathological entities.

Non-Planar Non-Linear Vibration Phenomenon on the One to One Resonance of the Circular Cantilever Beam (원형 외팔보의 일대일 공진에서의 비평면 비선형 진동현상)

  • Park Chul-Hui;Cho Chongdu;Kim Myoung-Gu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제30권2호
    • /
    • pp.171-178
    • /
    • 2006
  • Experimental and theoretical study of the non-planar response motions of a circular cantilever beam subject to base harmonic excitation has been presented in this paper work. Theoretical research is conducted using two non-linear coupled integral-differential equations of motion. These equations contain cubic linearities due do curvature term and inertial term. A combination of the Galerkin procedure and the method of multiple scales are used to construct a first-order uniform expansion for the case of one-to-one resonance. The results show that the non-linear geometric terms are very important for the low-frequency modes of the first and second mode. The non-linear inertia terms are also important for the high-frequency modes. We present the quantitative and qualitative results for non-planar motions of the dynamic behavior.

A Theoretical Study for the Thermal Diffusivity Measurement of Semi-Infinite Solid Using Photothermal Displacement Method (광열변위법을 이용한 반무한 고체의 열확산계수 결정에 대한 이론적 연구)

  • Jeon, Pil-Soo;Lee, Kwang-Jai;Yoo, Jai-Suk;Park, Young-Moo;Lee, Jong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제26권12호
    • /
    • pp.1747-1755
    • /
    • 2002
  • A complete theoretical treatment of the photothermal displacement technique has been performed for thermal diffusivity measurement in semi-infinite solid materials. The influence of the parameters, such as radius and modulation frequency of the heating beam and the thermal diffusivity, was studied. Usually, thermal diffusivity was determined by the deformation angle and phase angle as the relative position between the heating and probe beams. In this study, we proposed the simple analysis method based on the real part of deformation gradient as the relative position between two beams. It is independent in the parameters such as power of heating beam, absorption coefficient, reflectivity, Poisson's ratio, and thermal expansion coefficient.

2-dimensional hologram formation by selective etching on amorphous As-Ge-Se-S thin film (비정질 As-Ge-Se-S 박막에서 선택적 에칭을 통한 2차원 홀로그램 제작)

  • Kim, Jin-Hong;Kang, Jin-Won;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1430-1431
    • /
    • 2006
  • We investigated the formation of 2-dimension hologram grating by means of selective etching characteristic and photo-expansion effect according to photo irradiation on amorphous As-Ge-Se-S thin film. By method of phase holography, we made the 2-dimensional hologram grating by each (S:P) and ($+45^{\circ}:-45^{\circ}$) polarized beam with DPSS laser(532nm) and He-Ne laser(632nm). A recording property was observed at each polarized beam through 2-dimensional hologram surface relief grating. Chalcogenide thin film was etched selectively by NaOH solution after the formation of 1-dimensional diffraction grating. And then etched sample was rotated 90 degree to fabricate 2 dimensional hologram grating. We found that it was observed the formation of 2-dimensional hologram grating by AFM(Atomic Force Microscopy).

  • PDF

Atypical periosteal reaction and unusual bone involvement of ameloblastoma: A case report with 8-year follow-up

  • Charoenlarp, Pornkawee;Silkosessak-Chaiudom, Onanong;Vipismakul, Vichittra
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.195-201
    • /
    • 2021
  • Unusual radiographic findings of intraosseous ameloblastoma have been reported and discussed. In the case discussed herein, cone-beam computed tomography (CBCT) clearly showed many radiographic features that were ambiguous on conventional radiographs, including an ill-defined periphery, extensive superficial buccal extension with minimal lingual extension, obvious bucco-crestal expansion, and multiple triangular (Codman's triangle-like) areas of periosteal reaction. Based on the above-mentioned findings, the differential diagnosis was a long-term infected benign or low-grade malignant lesion. An incisional biopsy was performed, and the histopathologic diagnosis was acanthomatous ameloblastoma. Recurrence of the lesion was clearly detected on CBCT images at 4 and 8 years after surgery. These unusual radiographic findings have never been reported to be associated with ameloblastoma, and thus may contribute to novel concepts in radiographic interpretation in the future. This report also underscores the important role played by CBCT as a comprehensive diagnostic tool and for definite confirmation of recurrence.

Evaluation of the Midpalatal Suture Maturation in Young Koreans Using Cone-Beam Computed Tomography

  • Kim, In-Seok;Kim, Hye-Won;Choi, Young-Jun;Choi, Won-Cheul
    • Journal of Korean Dental Science
    • /
    • 제11권1호
    • /
    • pp.1-4
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the ossification and maturation of the midpalatal suture in young Koreans using cone-beam computed tomography (CBCT). Materials and Methods: The study sample consisted of 40 patients with ages from 8.2 to 23.6 years who visited the Department of Orthodontics, Chung-Ang University Dental Hospital. CBCT images were taken for diagnosis. From the CBCT image, morphological stages and Hounsfield units (HU) of midpalatal suture were obtained to evaluate the midpalatal suture maturation. Spearman's correlation coefficients were calculated to analyze relationships between chronological age, morphological stage, and HU. Result: There was a wide variation in the morphology of the midpalatal suture in each age group. It showed a modest relationship between the chronological age and the degree of morphological stages. Also there was a modest relationship between the chronological age and HU. In contrast, there was a significant relationship between morphological stages and HU of midpalatal suture (P<0.01). Conclusion: CBCT images can be used for the evaluation of midpalatal suture maturation. For the estimation of the prognosis of rapid maxillary expansion, CBCT may be reliable for the assessment of the maturation of the midpalatal suture.