• Title/Summary/Keyword: Basic Data of Architectural Design

Search Result 184, Processing Time 0.025 seconds

Estimation of Wind Speeds for Return Period in Cellularized District of Basan by the Recent Meteorological Data (최근 기상 자료에 의한 부산의 세분화된 지역별 재현기대 풍속 산정)

  • An, Jae-Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.158-163
    • /
    • 2012
  • This study is concerned with the estimation of wind speeds for return period in cellularized district of Busan by the recent meteorological data. Recently standard of the wind load in Busan area is determined by using meteorological wind speed data which is observed on Automated Synoptic Observing System(ASOS) only. Applying the existing basic wind speed that is 40m/s to the construction design of Busan area is inefficient. Because the wind speeds of Busan area show different amounts depend on the location of cellularized district. This research analyze the observed data of wind speeds of cellularized district in Busan based on Automate Weather System(AWA). In addition that we compute regional wind speeds for return period by using Gumbel distribution and study and compare with the existing basic wind speeds after evaluating appropriateness by Hazen's plot method.

A Study on the shrine plan composition from the Ungjindan excavation works (웅진단 발굴에 따른 사당의 평면구성에 관한 연구)

  • Kim, Sang-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.186-193
    • /
    • 2012
  • This study is to reveal the periodical form of the 4 staged building sites with the size and the site composition of the master plan and floor plan of the Ungjindan (altar) from the Ungjindan excavation works in 2011. In order to project the research results aiming to the purpose of the study, the basic study was done with collecting data about shrine architecture for its architectural characteristics and case studies with ancestral facilities such as the Ak hae dok (national-level ancestral ritual to the big mountain, ocean and river) to understand the exact form of the site plan and architectural composition elements through the general information and excavation status. In addition, with the current situation and information from the excavation works the planned measurement scale will be calculated in inference for the size of the construction by stages and speculate the floor plan composition of the shrine architecture.

  • PDF

A Study on the Architectural Planning for Integrated Nursing Care Service in Ward of Public Hospital - Focused on the Regional Public Hospital in Korea - (간호·간병통합서비스를 위한 국내 공공병원 병동부에 대한 건축 계획적 연구 - 국내 지역거점 지방의료원을 중심으로 -)

  • Han, Suk-Bum;Park, Jae-Seung
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.121-129
    • /
    • 2017
  • The study is to identify the status of the ward of public hospital for integrated nursing care service. Integrated nursing service has expanded nationwide from 2016 but 10 out of 34 public hospitals are currently unable to operate as nurses due to the shortage. Analyze each floor plan and space program of ward and provide the basic data for the construction of the architecture plans for Integrated nursing care service. For this study, selecting 14 wards of public hospital in Korea and then analyzes space organization, distance from NS to bedroom and NS to core(Elevator) and spatial hierarchy of them. Among the 14 public hospitals, there are 7 types of double-loaded corridor, 4 types of double corridor and 3 types of single corridor. If NS is placed centrally, the control of the outsider and the patient's control would be efficient, but most of NS are lean on one side of floor. the placement of NS should be independent of individual arrangements, but it should be smooth alignment with patient spaces, staff spaces, and public spaces. This study could serve as basic research for the architectural plan for future integrated nursing care in ward of public hospital.

Life Cycle Costing through Operating Number Control of Air Conditioning Systems in Office Buildings (사무소 건축물의 공조시스템 대수제어 여부에 따른 LCC 분석)

  • Park, Ryul;Jung, Soon-Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.981-988
    • /
    • 2002
  • Generally, the term "energy saving is economical" is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing the system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning system. For this reason, this research can provide the economics through operating number control as basic design data. The data obtained through assesment of Life Cycle Cost based on amount of yearly energy use, were produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating/cooling systems based on constant air volume conditioning system, which is widely used for medium and large office buildings in Busan.

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter (동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구)

  • Ryu, Ri;Seo, Jang-hoo;Kim, Yong-seong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

A Study on the analysis of architectural Design corresponding to the Landscape Housing - Focused on individual house in Gangwon Province - (경관주택의 건축의장 분석에 관한 연구 -강원지방의 단독주택을 중심으로-)

  • Cho, won-seok;Kim, Heung-Gee;Cho, hyoung-seok
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.7 no.2
    • /
    • pp.48-55
    • /
    • 2005
  • The purpose of this paper is to develop planning of individual house in Gangwon Provinces. Above all important two conditions, such as changes of life style and building trends are to analyze for landscape. Thus the major analysis is to take basic data about planning. For the feasiblity of these condition, roof type, color, context can be checked and design of landscape may be possible to work out optimum housing for the environments. This study suggests that house of future is to be environmental landscape design. The result of this study, proposal of guideline will be useful to make out design data individual house for the form programming phase of schematic designing in landscape Housing.

  • PDF

A Study on the BIM based architectural design process for APT. competition (공동주택 현상설계의 BIM 프로세스 적용 방안에 관한 연구)

  • Lee, Kwang-Soo;Min, Young-Gi;Kim, Myoung-Keun;Koh, In-Lyong
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.3
    • /
    • pp.89-97
    • /
    • 2011
  • Accelerating economic growth since the 1960s, penetration rate of the House of Commons has been increased. However, design competition has been imposed for improve of the qualitative level in modern because it was quantitative increasing. Even though its design quality is improved by introducing design competition, distorting the design is increased for the purpose of election. For that reason, errors of information and design changes are increased. So BIM(Building Information Modeling) is adopted to solve the problems. In this study, BIM process on the basis of the existing design process was to clean up and LoI(Level Of Information) based on the level of information was newly defined. Working-level of the design competition is plan-basic design. LOI level is LOI1-LOI2 in plan and Lol3-LOI4 in basic design. At each step of the operation was to clean up the level of detail and content. Also exchange of data in each area and feedback about content are to clean up.

Characteristics of Physical Setting of Adult Day Care Center for the Elderly with Dementia in the U.S.A. (치매노인을 위한 주간보호시설의 물리적 환경 특성에 관한 연구 - 미국의 사례를 중심으로 -)

  • 곽인숙
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.7
    • /
    • pp.193-210
    • /
    • 2002
  • The purpose of this study is to identify the characteristics of physical setting of adult day care as a place for the elders and adult and to develop an basic understanding of the architectural program and physical setting for adult day care for the cognitively-impaired in the U.S.A. The data was collected from 13 Adult Day Care Centers(ADCC) from 2001 to 2002 by interview and the documents about those facilities. Physical environment should be viewed as an element in the care of individuals with dementia, and that the principles used to plan and design environment should be consistent with the principles used in providing other aspects of care. The results of the study provided the information about the best condition of physical setting of ADCC for the elderly with dementia. Memory Loss Adult Day Center and St. Ann Center for Intergenerational Care have better architectural program than other facilities. It is the hope of this study to provide guideline for design and care professionals with a first draft of a "sense-making" template and to slow own the progression of the disease by the appropriate physical environment.

A Study on the Space Programming of the Medical Recording Department in the General Hospital (종합병원 의무기록부의 규모계획에 관한 연구)

  • Ryu, Jae-Kwon;Lee, Nak-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.3 no.4
    • /
    • pp.27-34
    • /
    • 1997
  • This study aims at proposing the basic architectural data of the medical recording department for the general hospital planning and design. This research investigated the size of working space and the chart custody space through actual survey and the present conditions of space were analyzed. In result, this study proposes the formula for the calulation of the chart custody space according to computerization level and the chart custody planning year.

  • PDF

Forecasted Weather based Weather Data File Generation Techniques for Real-time Building Simulation (실시간 빌딩 시뮬레이션을 위한 예측 기상 기반의 기상 데이터 파일 작성 기법)

  • Kwak, Young-Hoon;Jeong, Yong-Woo;Han, Hey-Sim;Jang, Cheol-Yong;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.8-18
    • /
    • 2014
  • Building simulation is used in a variety of sectors. In its early years, building simulation was mainly used in the design phase of a building for basic functions. Recently, however, it has become increasingly important during the operating phase, for commissioning and facility management. Most building simulation tools are used to estimate the thermal environment and energy consumption performance, and hence, they require the inputting of hourly weather data. A building simulation used for prediction should take into account the use of standard weather data. Weather data, which is used as input for a building simulation, plays a crucial role in the prediction performance, and hence, the selection of appropriate weather data is considered highly important. The present study proposed a technique for generating real-time weather data files, as opposed to the standard weather data files, which are required for running the building simulation. The forecasted weather elements provided by the Korea Meteorological Administration (KMA), the elements produced by the calculations, those utilizing the built-in functions of Energy Plus, and those that use standard values are combined for hourly input. The real-time weather data files generated using the technique proposed in the present study have been validated to compare with measured data and simulated data via EnergyPlus. The results of the present study are expected to increase the prediction accuracy of building control simulation results in the future.