• Title/Summary/Keyword: Basic Contaminants

Search Result 72, Processing Time 0.02 seconds

Impact of UV-C Irradiation on Bacterial Disinfection in a Drinking Water Purification System

  • Hyun-Joong Kim;Hee-Won Yoon;Min-A Lee;Young-Hoon Kim;Chang Joo Lee
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.106-113
    • /
    • 2023
  • The supply of microbiological risk-free water is essential to keep food safety and public hygiene. And removal, inactivation, and destruction of microorganisms in drinking water are key for ensuring safety in the food industry. Ultraviolet-C (UV-C) irradiation is an attractive method for efficient disinfection of water without generating toxicity and adversely affecting human health. In this study, the disinfection efficiencies of UV-C irradiation on Shigella flexneri (Gram negative) and Listeria monocytogenes (Gram positive) at various concentrations in drinking water were evaluated using a water purifier. Their morphological and physiological characteristics after UV-C irradiation were observed using fluorescence microscopy and flow cytometry combined with live/dead staining. UV-C irradiation (254 nm wavelength, irradiation dose: 40 mJ/cm2) at a water flow velocity of 3.4 L/min showed disinfection ability on both bacteria up to 108 CFU/4 L. And flow cytometric analysis showed different physiological shift between S. flexneri and L. monocytogenes after UV-C irradiation, but no significant shift of morphology in both bacteria. In addition, each bacterium revealed different characteristics with time-course observation after UV-C irradiation: L. monocytogenes dramatically changed its physiological feature and seemed to reach maximum damage at 4 h and then recovered, whereas S. flexneri seemed to gradually die over time. This study revealed that UV-C irradiation of water purifiers is effective in disinfecting microbial contaminants in drinking water and provides basic information on bacterial features/responses after UV-C irradiation.

Research on the Actual State of Environmental Disease and Health Education at Middle and High School Students (일 지역 중.고등학생들의 환경성 질환 및 보건교육 실태 조사)

  • Jung, Jong-Hyeon;Moon, Ki-Nai;Seo, Bo-Soon;Kim, Chang-Tae;Lee, Jae-Hong
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.12 no.3
    • /
    • pp.65-87
    • /
    • 2011
  • Objectives: The purpose of this study was to perform basic study on environmental and respiratory diseases in Ulsan and vicinities. Also, this study evaluated the actual state of environmental disease and health education at middle and high schools in Ulsan and surroundings. Methods: For this study, we conducted a survey on the health of the general public, environmental effects, and investigated the characteristics of environmental disease, health and hygiene education, etc. The populations of this study were middle and high school students in Ulsan, Korea. This study investigated the knowledge of environmental disease and health education at schools in Ulsan and vicinities from November 2009 to December 2009. All statistical calculations were performed with Statistical Package for Social Sciences (SPSS) for Windows, and gained the following results by implementing Frequency Analysis, Cross-tabulation Analysis and ANOVA. Results: As more and more environmental diseases are increased, the interest of the people has been increasing on this. The incidence rates of asthma and atopy were represented the top 25% of the country in Korea. The source of heavy metal, PAHs and VOCs in Ulsan includes the Petrochemical Complex at Nam-gu and Ulju-gun, the Nonferrous Metal Industrial Complex at Onsan-eup, Ulju-gun, and the Heavy Industrial Complex at Dong-gu and Buk-gu. Especially, there are a number of fossil fuel combustion facilities such as waste incineration plants and boilers at Nam-gu and the Onsan Industrial Complex. It may help greatly to investigate the characteristics of environmental pollutants such as environmental air pollutant and indoor contaminant to better manage the local student's health. Conclusions: It has been revealed that the hazardous chemicals and environmental contaminants are main substances of cause for asthma, atopy, dermatitis, and allergy disease. Therefore, through with collecting basic data such as environmental disease of inhabitants, health education, conscious and knowledgeable level in parents of students and students, We have to exert to improve knowledge and prevention with health life in school through development of health education program systematically for preventing of environmental disease.

  • PDF

A Toolbox Approach for the Environmental Site Assessment of a Chemical Plant in a Coastal Area (연안지역 화학공장부지의 부지환경평가를 위한 복합조사기법의 적응)

  • Choi, Seung-Jin;Woo, Nam-Chil
    • Economic and Environmental Geology
    • /
    • v.40 no.4
    • /
    • pp.419-443
    • /
    • 2007
  • Recently, the branch-out of foreign companies into domestic markets through M&A and the opened followed by the Free Trade Agreement(FTA) with America have made the environmental site assessments of specific site more necessary. In this study, through case study of conducting actual environmental site assessment by use of a toolbox approach at a large scale of chemical plant with various contaminants located in a coastal area, the problems of guideline of domestic environmental assessment of soil were complemented. And an efficient and economical assessment was achieved. All six steps such as basic investigation, environmental site history survey, sampling and analysis, installation of monitoring wells and hydrogeological survey, and data interpretation were conducted in this study. All results of document survey, geological lineament analysis, field geology survey of surrounding area, geophysical prospecting of the site, hydraulic conductivity, measurement of groundwater flow rate and direction, sampling and analysis at each step were associated and estimated as an integrated tool box approach. As a consequence of this study, toolbox approaches were very useful techniques for contamination level and site characterization of subsurface media. The given conditions to conduct a basic survey for domestic soil environment assessment of site by use of existing documents, as well as interviews with the owner/manager/user of all adjacent properties and thorough review of all practically reviewable records pertaining to the property and surrounding properties within "Guideline for Soil Environment Assessment" radii are very poor. As a result, the application of toolbox approach in the environment site assessment of site is not only more efficient and economical, but also could be very useful assessment to integrate the soil and groundwater contamination.

Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process (반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템)

  • Choi, Kwang-Min;Lee, Ji-Eun;Cho, Kwi-Young;Kim, Kwan-Sick;Cho, Soo-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

Binary and Ternary Competitive Adsorption of Basic Dyes from Aqueous Solution onto the Conchiolin Layer (수용액에서의 이성분 및 삼성분 염기성 염료의 진주층에 대한 경쟁흡착)

  • Shin, Choon-Hwan;Song, Dong-Ik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.270-275
    • /
    • 2006
  • The cultivated pearls collected for the study were pretreated through the removal of contaminants and the surface bleaching for easy dyeing. Coloring of pearls are necessary after selecting dyes adsorbable to the Conchiolin layer, a kind of hard protein formed in the seawater, covering the surface of the pretreated pearls. Dyes adsorbable to the Conchiolin layers are mostly basic dyes such as Rhodamine 6G(R6G), Rhodamine B(RB), Methylene Blue(MB) etc. and the binary and ternary competitive adsorption were performed by mixing two or three dyes together. The multi-dye adsorption data were compared with the predictions from the ideal adsorbed solution theory(IASI) combined with the single-dye adsorption model, the Langmuir or the Redlich-Peterson(RP) model. The quality of prediction was compared by using determination coefficient($R^2$) and standard deviation(SSE) values. Predictions from the IAST were found to be in good agreement with the data for the R6G/RB binary adsorption to the pearl layers not fractionated with their size, except for the adsorption data for RB at high concentrations. Among the three binary adsorption systems, R6G/RB, R6G/MB, and MB/RB, only the RB sorption data in the R6G/RB binary system was in poor agreement with the IAST prediction. Competitive adsorption data in ternay systems were in good agreement with the predictions from the IAST except for the RB data.

Ultra Dry-Cleaning Technology Using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 초순수 건식 세정기술)

  • Joung, Scung Nam;Kim, Sun Young;Yoo, Ki-Pung
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.13-25
    • /
    • 2001
  • With fast advancement of fine machineries and semiconductor industries in recent decades, the ultra-cleaning of organic chemicals, submicron particles from contaminated unit equipments and products such as silicon wafers becomes one of the most important steps for further advancement of such industries. To date, two kinds of ultra cleaning techniques are used; one is the wet-cleaning and the other is the dry cleaning. In case of wet cleaning, removal of organic contaminants and submicron particles is made by DIW with additives such as $H_2O_2$, $H_2SO_4$, HCl, $NH_4OH$ and HF, etc. While the wet cleaning method is most widely adopted for various occasions, it is inevitable to discharge significant amount of toxic waste waters in environment. Dry cleaning is an alternative method to mitigate environmental pollution of the wet cleaning with maintaining comparable degree of cleaning to the wet cleaning. Although there are various concept of dry cleaning have been devised, the dry cleaning with environmentally-benign solvent such as carbon dioxide proven to show high degree of cleaning from the contaminated porous surface as well as from the bare surface. Thus, special global attention has been placing on this technique since it has important advantages of simple process schemes and no environmentally concern, etc. Thus, this article critically reviews the state-of-the-art of the supercritical fluid drying with emphasis on the thermo-physical characteristics of the supercritical solvent, environmental gains compared to other dry cleaning methods, and the generic aspects of the basic design and processing engineering.

  • PDF

Absorbance Elevation of Orimax Blue 2N, Orimax Green 151, Quinizarin, Topasol (P-250) and Lubricant (P-8) on the Spectrophotometric Analysis of Unimark 1494 DB (식별제(Unimark 1494DB) 정량시험에서 파란색 색소(Orimax Blue 2N, Orimax Green 151), Quinizarin, 토파졸(P-250) 및 윤활유 원료(P-8)의 흡광도상승 효과)

  • Lee, Ji-Yun;Kim, Chang-Jong
    • YAKHAK HOEJI
    • /
    • v.50 no.5
    • /
    • pp.313-321
    • /
    • 2006
  • There are three kinds of liquid petroleum marker which is extracted by the basic or acidic, and both developer. Korean marker, Unimark 1494 DB (marker) have been spectrophotometrically analysed by the determination of absorbance at 582 nm after base extraction by Unimark 1494 DB Developer C-5 (developer). Some blue dyes which have same reactive radical of marker and can be changed deep blue color in base developer extraction (BDE), may be increased absorbance at 582 nm, but dyes or markers which can be increased the absorbance, were not unclear. In this experiment, effects of three dyes or marker such as Orimax Green 151 (the mixture of CI Solvent Yellow 16 and CI Solvent Blue 70), quinizarin and Orimax Blue 2N (CI Solvent Blue 35), and two solvent such as topasol (P-250) and lubricant (P-8) on the absorbance were studied by HITACHI Recording Spectrophotometer U-3300. It shows that all of them increased absorbance at 582 nm after BDE. Absorbance at 582 nm can be showed 0.0544 by Orimax Green 151 at the concentration of 3.96 mg/l, quinizarin at the concentration of 1.38 mg/l, and Orimax Blue 2N at the concentration of 2.73 mg/l in the artificial petroleum (normal diesel oil: topasol: lubricant=2 : 4: 4), respectively. Absorbance, 0.0544 indicates that concentration of marker is 1.64 mg/l in the reference curves, respectively. And also these results can be showed that the artificial petroleum have about 10% cheep fuel such as kerosene which have marker (16.0 mg/l). Absorbance of P-250 was 0.01361-0.22842 depending upon the purchasing date, and that of P-8 was 0.05644. pH of developer was 14.83, and so this result indicates that Unimark 1494 DB is a base extractable petroleum marker, phenylazophenol (US Patent No. 5,252,106). In the BDE, the slight color of Orimax Blue 2N, Orimax Green 151 and quinizarin in artificial petroleum changed to deep bright blue color, respectively. These result indicate that the absorbance at 582 nm by BDE may be increased not only by azo, diazo, amine and ketone (anthraquinone, coumarin) dyes or markers, but also the contaminants of P-250 and P-8 which have same as reactive radical of dyes or markers.

Electrolytic Decontamination of the Dismantled Metallic Wastes Contaminated with Uanium Compounds in Neutral Salt Solutions (중성염 용액 내에서 우라늄으로 오염된 금속성 해체폐기물의 전해제염)

  • 최왕규;이성렬;김계남;원휘준;정종헌;오원진
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.72-80
    • /
    • 2004
  • Electrolytic dissolution study was carried out to evaluate the applicability of electrochemical decontamination process using a neutral salt electrolyte as a decontamination technology for the recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant using SUS-304 and Inconel-600 specimen as the main materials of internal system components of the plant. The effects of type of neutral salt as an electrolyte, current density, and concentration of electrolyte on the dissolution of the materials were evaluated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as $UO_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion plant were peformed in $Na_2SO_4$ and $NaNO_3$ solution. It was verified that the electrochemical decontamination of the dismantled metallic wastes was quite successful in $Na_2SO_4$ and $NaNO_3$ neutral salt electrolyte by reducing $\beta$ radioactivities below the level of self disposal with authorization within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

Investigation on Water Purification Effect Through Long-Term Continuous Flow Test of Porous Concrete Using Effective Microorganisms (유용미생물을 이용한 포러스 콘크리트의 장기간 연속흐름 실험을 통한 수질정화 효과 검토)

  • Park, Jun-Seok;Kim, Bong-Kyun;Kim, Woo-Suk;Seo, Dae-Sok;Kim, Wha-Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.219-227
    • /
    • 2014
  • The purpose of this study is to investigate water purification properties of porous concrete by using effective microorganisms through the long-term continuous flow test. To solve the problems such as desorption of conventional microorganisms, in this study, tertiary treatment of the effective microorganisms identified by 16S rDNA sequence analysis was adopted per each step in the manufacturing process of porous concrete. And concentration for optimum continuous flow test and operation conditions through basic experiments according to retention time were investigated. Based on the experimental results, the porous concrete applying effective microorganisms showed no toxicity on the biological water quality and exhibited excellent removal efficiency than normal porous concrete. Therefore, contaminated water quality would be improved by treatment performance investigation of contaminants through long-term continuous flow test. If problems are complemented during the experiment process, it is expected to be able to reduce the non-point pollution sources flowing into river.

Effect of PAH on CYP1B1 Gene Expression (PAH가 CYP1B1 유전자 발현에 미치는 영향)

  • Seo, Mi-Jung;Min, Kyung-Nan;Sheen, Yhun-Yhong
    • Environmental Mutagens and Carcinogens
    • /
    • v.24 no.3
    • /
    • pp.121-127
    • /
    • 2004
  • Cytochrome P4501B1(CYP1B1) is known to be inducible by xenobiotic compounds such as policyclic aromatic hydrocarbon(PAH) and dioxins such as 2,3,7,8-tetrachloro-dibenzo-p-dioxin(TCDD). And these induction of CYP1B1 is also regulated by many categories of chemicals. In order to investigate the effects of several chemicals on CYP1B1 gene expression in Hepa-I and MCF-7 cells, 5' flanking DNA of human CYP1B1 was cloned into pGL3 basic vector containing luciferase gene, and then transfected into these cells. After treatment of chemicals, the luciferase activity was measured. CYP1B1 enzyme metabolize PAHs and estradiol. CYP1B1 metabolize estradiol to 4-hydrozyestradiol that is considered as carcinogenic metabolite. Luciferase activity was induced about 20 folds over that control by 1 nM TCDD (2,3,7,8-tetrachloto-p-dioxin). Recent industrialized society, human has been widely been exposed to widespread environmental contaminants such as PAHs(polycyclic aromatic hydrocarbon) that are originated from the imcomplete combustion of hydrocarbons. PAHs are known to be ligands of the AhR(aryl hydrocarbon receptor). Induction of cytochrome P4501B1(CYP1B1) in cell culture is widely used as a biomarker for PAHs. Therefore we have studied the effect of PAHs in the human breast cancer cells MCF-7 to evaluate bioactivity of PAHs. We have used the United State of America EPA selected 13 different PAHs, PAHs mixtures and extracts from environmental samples to evaluate the bioassay system. We examined effects of PAHs on the CYP1B1-luciferase reporter gene and CYP1B1 mRNA level. Benzo(k)fluoranthene and dibenzo(a, h)anthracene showed strong response to CYP1B1 promoter activity stimulation, and also CYP1B1 mRNAs increase in MCF-7 cells in a concentration-dependent manner. Acenaphthene, anthracene, benzo(b)fluoranthene, fluorene, fluoranthene, anphthanlene, pyrene, phenanthrene and carbazole were weak responders in MCF-7 cells. RT-PCR analysis indicated that PAHs significantly up-regulate the level of CYP1B1 mRNA.

  • PDF