• 제목/요약/키워드: Base-isolated Bridge

검색결과 23건 처리시간 0.02초

Earthquake response of isolated cable-stayed bridges under spatially varying ground motions

  • Ates, Sevket;Soyluk, Kurtulus;Dumanoglu, A. Aydin;Bayraktar, Alemdar
    • Structural Engineering and Mechanics
    • /
    • 제31권6호
    • /
    • pp.639-662
    • /
    • 2009
  • A comprehensive investigation of the stochastic response of an isolated cable-stayed bridge subjected to spatially varying earthquake ground motion is performed. In this study, the Jindo Bridge built in South Korea is chosen as a numerical example. The bridge deck is assumed to be continuous from one end to the other end. The vertical movement of the stiffening girder is restrained and freedom of rotational movement on the transverse axis is provided for all piers and abutments. The longitudinal restraint is provided at the mainland pier. The A-frame towers are fixed at the base. To implement the base isolation procedure, the double concave friction pendulum bearings are placed at each of the four support points of the deck. Thus, the deck of the cable-stayed bridge is isolated from the towers using the double concave friction pendulum bearings which are sliding devices that utilize two spherical concave surfaces. The spatially varying earthquake ground motion is characterized by the incoherence and wave-passage effects. Mean of maximum response values obtained from the spatially varying earthquake ground motion case are compared for the isolated and non-isolated bridge models. It is pointed out that the base isolation of the considered cable-stayed bridge model subjected to the spatially varying earthquake ground motion significantly underestimates the deck and the tower responses.

지반조건에 대한 면진교량의 지진응답 비교 (Seismic Response of Base-Isolated Bridge for Soil Types)

  • 성낙구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.455-462
    • /
    • 2000
  • In this study seismic response of a base-isolated bridge for soil types is compared. Bilinear model is used for lead rubber bearing(LRB). Accelerograms whose response spectrum matches the design spectrum for soil types are used as earthquake ground excitation. Nonlinear time history analyses using the SAP2000 program is performed. The results show that seismic response of a base-isolated bridge is increased as the soil becomes soft.

  • PDF

Comparison of the dynamic responses of $G\ddot{u}lburnu$ Highway Bridge using single and triple concave friction pendulums

  • Yurdakul, Muhammet;Ates, Sevket;Altunisik, Ahmet Can
    • Earthquakes and Structures
    • /
    • 제7권4호
    • /
    • pp.511-525
    • /
    • 2014
  • The main object of this study is to determine and compare the structural behavior of base isolated long span highway bridge, $G\ddot{u}lburnu$ Highway Bridge, using single concave friction pendulum (SCFP) and triple concave friction pendulum (TCFP). The bridge is seismically isolated in the design phase to increase the main period and reduce the horizontal forces with moments using SCFP bearings. In the content of the paper, firstly three dimensional finite element model (FEM) of the bridge is constituted using project drawings by SAP2000 software. The dynamic characteristics such as natural frequencies and periods, and the structural response such as displacements, axial forces, shear forces and torsional moments are attained from the modal and dynamic analyses. After, FEM of the bridge is updated using TCFP and the analyses are performed. At the end of the study, the dynamic characteristics and internal forces are compared with each other to extract the TCFP effect. To emphasize the base isolation effect, the non-isolated structural analysis results are added to graphics. The predominant frequencies of bridge non-isolated, isolated with SCFP and isolated with TCFP conditions decreased from 0.849Hz to 0.497Hz and 0.338Hz, respectively. The maximum vertical displacements are obtained as 57cm, 54cm and 44cm for non-isolated, isolated with SCFP and isolated with TCFP conditions, respectively. The maximum vertical displacement reduction between isolated with TCFP bearing and isolated with SCFP bearing bridge is %23. Maximum axial forces are obtained as 60619kN, 18728kN and 7382kN, maximum shear forces are obtained as 23408kN, 17913kN and 16249kN and maximum torsional moments are obtained as 24020kNm, 7619kNm and 3840kNm for non-isolated, isolated with SCFP and isolated with TCFP conditions, respectively.

Experimental Study on Seismic Performance of Base-Isolated Bridge

  • Chung, Woo Jung;Yun, Chung Bang;Kim, Nam Sik;Seo, Ju Won
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.51-60
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrated that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation systems using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminate rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the deck acceleratino and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

지진격리 강재 케이블 교량의 다지점 진동대 실험 (Multi-support excitation shaking table test of a base-isolated steel cable-stayed bridge)

  • 김성도;안진희;공영이;최형석;정진환
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.161-171
    • /
    • 2015
  • A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.

지진 격리된 교량의 내진성능에 대한 실험적 연구 (Experimental Study on Seismic Performance of Base-Isolated Bridge)

  • Chung, Woo-Jung;Yun, Chung-Bang;Kim, Nam-Sik;Seo, Ju-Won
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.144-153
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrates that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation system using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminated rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

Seismic response analysis of isolated offshore bridge with friction sliding bearings

  • Wang, Baofu;Han, Qiang;Jia, Junfeng
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.641-654
    • /
    • 2019
  • This paper investigates the seismic response of a typical non-navigable continuous girder bridge isolated with friction sliding bearings of the Hong Kong-Zhuhai-Macao link projects in China. The effectiveness of the friction pendulum system (FPS) and accuracy of the numerical model were evaluated by a 1/20 scaled bridge model using shaking table tests. Based on the hysteretic properties of friction pendulum system (FPS), double concave friction pendulum (DCFP), and triple friction pendulum system (TFPS), seismic response analyses of isolated bridges with the three sliding-type bearings are systematically carried out considering soil-pile interaction under offshore soft clay conditions. The fast nonlinear analysis (FNA) method and response spectrum are employed to investigate the seismic response of isolated offshore bridge structures. The numerical results show that the implementation of the three sliding-type bearings effectively reduce the base shear and bending moment of the reinforced concrete pier, at the cost of increasing the absolute displacement of the bridge superstructure. Furthermore, the TFPS and DCFP bearings show better isolation effect than FPS bearing for the example continuous girder bridge.

인터넷을 이용한 면진 교량의 원격 병렬 유사동적실험 (Remote Parallel Pseudo-dynamic Testings Using Internet on Base-Isolated Bridge)

  • Chung-Bang. Yun;Park, Dong-Uk.;Eiichi Watanabe;Kazutoshi Nagata
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.521-528
    • /
    • 2003
  • This paper presents the results of a cooperative research on remote parallel pseudo-dynamic testing on a base-isolated bridge with multiple piers using Internet between KAIST, Korea and Kyoto Univ., Japan. Experimental facilities located at two institutions were parallelly used to test the nonlinear behavior of the base-isolators. Two data communication schemes for parallel tests were developed and the performance is compared. The results indicate that the elapsed time may vary widely depending on the data communication and testing schemes : i.e. 1-25sec for each time step. But it is fairly comparable with the time required for pseudo-dynamic testing. The testing method can become more powerful, as the data communication and monitoring techniques through Internet improve further.

  • PDF

다경간 연속교에 대한 면진용 교좌장치의 내진성능 비교연구 (A comparative study on aseismic performances of base isolation systems for multi-span continuous bridge)

  • Park, Kyu-Sik;Lee, Chong-Heon;Lee, In-Won
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.383-390
    • /
    • 2001
  • Various base isolation systems, which are widely used, are compared for aseismic performances of multi-span continuous bridge. They are the P-F, RB, LRB, R-FBI and EDF systems. Sensitivity analyses are carried out to determine the design parameters of various devices. The design parameters, natural period of the isolated bridge and friction coefficient of the bearing, are determined by the reciprocal relationship between displacement and bending moment of the structure. Then the relative effectiveness of the bearings is described. Bridge with the R-FBI system shows the smallest peak displacement of deck whereas bridge with the EDF system shows the smallest peak bending moment of the lower end of pier in numerical examples. Furthermore, the peak responses of bridge with the friction type bearing are less sensitive to substantial variations in the frequency range and intensity of the ground excitation than those with the rubber type bearing.

  • PDF

인터넷을 이용한 원격병렬 유사동적실험 : 면진교량에 대하여 (Remote Parallel Pseudo-Dynamic Testings Using Internet on Base Isolated Bridge)

  • 윤정방;김재민;김남식;심종민;구기영
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.304-307
    • /
    • 2000
  • This paper presents a numerical simulation study for remote parallel pseudo-dynamic testings using Internet. In this testing method, experimental facilities located at different places can be parallelly used for testing a large-scale structure with many components subjected to severe nonlinear behavior. Example analysis is carried out on a base- isolated bridge for earthquake loading. The results indicate that the time required for data communication between two facilities located 250km apart through Internet for t 000 time steps is about 20 minutes, which is fairly equivalent to the time required for pseudo-dynamic testing. This testing method can be more powerful, as the data transmitting technique through Internet improves.

  • PDF