• 제목/요약/키워드: Base resin

검색결과 441건 처리시간 0.022초

Full-Grain 피혁용 수용성 아크릴 Base coat 수지의 합성 및 물성측정 연구 (A Study of Synthesis and Mechanical property measurement for Waterborne Acrylic Base coat Resin in Full-Grain Leather)

  • 이주엽;김기준
    • 한국응용과학기술학회지
    • /
    • 제28권3호
    • /
    • pp.359-366
    • /
    • 2011
  • In this study we experimented that how polyurethane effect to acrylic-polyurethane resin in Full-Grain leather coatings. First of all, we consummated waterborne acrylic emulsion and waterborne polyurethane resin, Than we prepared F.G leathers which were coated by acrylic resin and acrylic-polyurethane resins. According to measured data for solvent resistance, acrylic resin and acrylic-polyurethane resins had good property. Sample a(WAC) had most low strength($2.10kg_f/mm^2$) and sample d(WAC 93 : WPU 7) had most high strength($3.41kg_f/mm^2$). Also we knew that most good property of abrasion is d(47.4 mg). In elongation case, a(WAC) had most good result(645 %) in this experiment.

The influence of different base materials on marginal adaptation of direct class I composite resin restorations

  • Cho, Yong-Sik;Park, Sung-Ho
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.619-619
    • /
    • 2003
  • This study was intended to evaluate the influence of different base materials on the marginal integrity of posterior direct composite resin restorations. Large conventional butt-joint MOD cavity preparations, with margins in enamel and dentin, were prepared in vitro in 24 extracted human mandibular molars and randomly divided into four equal groups. One of three base materials(RMGI, compomer, flowable resin) was placed on the pulpal floors, of the teeth of the groups. One group of teeth, which served as the control group, was not given any base mterial.(중략)

  • PDF

복합(複合)레진과 세균(細菌)이 치수반응(齒髓反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE EFFECT OF COMPOSITE RESIN AND BACTERIA TO PULP RESPONSE)

  • 조성식;김영해
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.53-67
    • /
    • 1988
  • An investigation was carried out to compare the pulp responses against a few type of composite and streptococcus mutans contamination under the zinc oxide eugenol cement, and also confirmed pulpal responses of various composites with or without base. Seventy eight teeth from 6 dogs were employed and divided into 6 groups. Class V cavities were prepared on each tooth routinely with low speed dental engine. Paper disc about 0.3mm thick was immersed in the BHI broth in which streptococcus mutans had been enriched and the disc was inserted on the cavity floor prior to filling. Scotch bond puls Silux as Bis-GMA system composite resin and Helimolar as urethane system composite resin were adopted. Control group: Zinc-Oxide Eugenol cement filling Experimental groups: Group 1. Scotch bond + Silux filling with Dycal base Group 2. Heliomolar filling with Dycal base Group 3. Scotch bond + Silux filling without base Group 4. Heliomolar filling without base Group 5. Streptococcus mutans application. All cavities were sealed with thick ZOE cement to avoid marginal leakage. Postoperative intervals of 1, 2, 3, 4, 5 and 6 weeks teeth were carefully extracted, processed and stained with Hematoxylin and Eosin. The results were as follows: 1. S. mutans application group and composites without any base showed more severe pupal response than control group and dyca based groups. 2. The experimental group of S. mutans application showed severe response in the early stage compared to the two groups of composite resin without base, but no significant difference was found following periods. 3. The difference of pulpal response is not significant between Bis-GMA system and urethane system. 4. Streptococcus mutans application group and composites without base groups showed the evidence of histologic recovery at the six week cases and the large amount of reparative dentin was the prominent feature. 5. Pulp responses against every material were inclined to normal according to the time elapsed.

  • PDF

이온교환법에 의한 탈질소 공정개발의 기초연구(II) (Basic Study for Development of Denitrogenation Process by ion Exchange(II))

  • 이민규;주창식
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.89-95
    • /
    • 1998
  • Ion exchange performance to remove nitrate in water was studied using commercially available strong base anion exchange resin of Cl- type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium conquilibrium between resin and solution. Anion exchange resin used in this study was more effective than activated carbon or zeolite for nitrate removal. With large resin amount or low initial concentration, nitrate removal characteristics for a typical gel-type resin was Increased. On considering the relation between the breakthrough capacity and nitrate concentration of the influent, the use of anion exchange resin were suitable for the hi선or order water treatment. The nitrate removal of above 90% could be possible until the effluent of above 650 BV was passed to the column. Thus, the commercially available strong base anion exchange resin of $Cl^-$ type used in thins study could be effectively used as economic material for treatment of the groundwater. The breakthrough curves showed the sequence of resin selectivity as $SO_4^{2-}$ > $NO_3$ > $NO^{2-}$ > $HCO_3^-$. The results of this study could be scaled up and used as a design tool for the water purification system of the real groundwater and surface water treatment processes.

  • PDF

유리섬유 보강재 첨가에 따른 레진 의치상의 강화효과 (Strengthening effect of resin denture base by glass fiber reinforcement addition)

  • 김총명;김지환;김혜영;김웅철
    • 대한치과기공학회지
    • /
    • 제36권1호
    • /
    • pp.1-7
    • /
    • 2014
  • Purpose: The aim of this study was analyzed by comparing the effect of glass fiber reinforcement addition on the strength of resin denture base. It was intended to provide a reference data useful for clinical application. Methods: The test specimens (length $64.0{\pm}0.1mm$, width $10.0{\pm}0.1mm$, thickness $1.0{\pm}0.1mm$, $1.5{\pm}0.1mm$, and $2.0{\pm}0.1mm$ respectively) were made. In the experimental groups resin denture base reinforced with glass fiber were fabricated. In the control groups resin denture base were fabricated by conventional method. After specimen fabrication was completed, transverse test was performed using a universal testing machine. Results: The transverse strength value in CON group was $83.08{\pm}9.07MPa$ for 1.0 mm, which ranked the highest in value. On the other hand, the value was $56.07{\pm}5.15MPa$ for 2.0mm, which ranked the lowest in value. And CON+SES group was $119.80{\pm}30.70MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $84.00{\pm}7.97MPa$ for 2.0mm, which ranked the lowest in value. Also, the flexural modulus value in CON group was $2,983.10{\pm}506.92MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $1,257.64{\pm}230.48MPa$ for 2.0mm, which ranked the lowest in value. And CON+SES group was $4,679.41{\pm}1578.29MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $2,512.36{\pm}527.09MPa$ for 2.0mm, which ranked the lowest in value. Conclusion: The reinforced glass fiber increased the strength of resin denture base, effected to reduce the thickness of resin denture base.

Flexural properties of a light-cure and a self-cure denture base materials compared to conventional alternatives

  • Mumcu, Emre;Cilingir, Altug;Gencel, Burc;Sulun, Tonguc
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권3호
    • /
    • pp.136-139
    • /
    • 2011
  • PURPOSE. A new light curing urethane dimethacrylate and a cold curing resin with simpler and faster laboratory procedures may have even improved flexural properties. This study investigated the 3-point flexural strengths and flexural moduli of two alternate base materials. MATERIALS AND METHODS. A cold curing resin (Weropress) and a light curing urethane dimethacrylate base material (Eclipse). Along with Eclipse and Weropress, a high impact resin (Lucitone199) and three conventional base materials (QC 20, Meliodent and Paladent 20) were tested. A 3-point bending test was used to determine the flexural strengths and flexural moduli. The mean displacement, maximum load, flexural modulus and flexural strength values and standard deviations for each group were analyzed by means of one-way analysis of variance (ANOVA) (with mean difference significant at the 0.05 level). Post hoc analyses (Scheffe test) were carried out to determine the differences between the groups at a confidence level of 95%. RESULTS. Flexural strength, displacement and force maximum load values of Eclipse were significantly different from other base materials. Displacement values of QC 20 were significantly different from Lucitone 199 and Weropress. CONCLUSION. The flexural properties and simpler processing technique of Eclipse system presents an advantageous alternative to conventional base resins and Weropress offers another simple laboratory technique.

코발트-크롬 합금의 표면처리에 따른 열중합형 의치상용 레진과의 전단결합강도 (SHEAR BOND STRENGTH OF HEAT-CURED DENTURE BASE RESIN TO SURFACE TREATED CO-CR ALLOY WITH DIFFERENT METHODS)

  • 이상훈;황선홍;문홍석;이근우;심준성
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.216-227
    • /
    • 2007
  • Statement of problem: For the long-term success of removable partial dentures, the bonding between metal framework and denture base resin is one of the important factors. To improve bonding between those, macro-mechanical retentive form that is included metal framework design has been generally used. However it has been known that sealing at the interface between metal framework and denture base resin is very weak, because this method uses mechanical bonding. Purpose: Many studies has been made to find a simple method which induces chemical bond, now various bonding system is applied to clinic. In this experiment, shear bond strengths of heat-cured denture base resin to the surface-treated Co-Cr alloy were measured before and after thermocycling. Chemically treated groups with Alloy $Primer^{TM}$, Super-Bond $C&B^{TM}$, and tribochemically treated group with $Rocatec^{TM}$ system were compared to the beadtreated control group. The data were analyzed with two-way ANOVA. Result: 1. Shear bond strength of bead-treated group is highest, and Alloy $Primer^{TM}$ treated group, Super-Bond $C&B^{TM}$ treated group, RocatecTM system treated group were followed. Statistically significant differences were found in each treated group(p<0.05). 2. Surface treatment and thermocycling affected shear bond strength(p<0.05), however there was no interaction between two factors(p>0.05). 3. Shear bond strengths of bead-treated group and Alloy $Primer^{TM}$ treated group showed no statistically significant difference before and after thermocycling(p>0.05), and those of Super-Bond $C&B^{TM}$ treated group and $Rocatec^{TM}$ system treated group showed statistically significant difference after thermocycling(p<0.05).

금속표면처리제에 따른 코발트-크롬 합금과 의치상용 레진의 결합강도 (BOND STRENGTH BETWEEN COBALT-CHROMIUM ALLOY AND DENTURE BASE RESIN ACCORDING TO ADHESIVE PRIMERS)

  • 박종일;권주홍;이해형;조혜원
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.160-168
    • /
    • 2000
  • This study evaluated the effects of four adhesive metal primers on the shear bond strength of a heat curing denture base resin(Lucitone 199) to cobalt-chromium alloy(Biosil-f). The adhesive metal primers were Cesead Opaque Primer, Metal Primer, MR Bond, and Super-Bond liquid. The metal surface primed or nonprimed was filled with the heat-curing methyl methacrylate resin. The specimens were stored in water at $37^{\circ}C$ for 24 hours and the alternately immersed in water bath at $5^{\circ}C\;and\;55^{\circ}C$ for up to 2,000 thermal cycles. Shear bond strengths were measured using UTM at a crosshead speed of 0.5mm/min. Failure surface were examined under magnifying glasses. All the primers examined improved the shear bond strength between denture base resin and cobalt-chromium alloy compared with nonprimed specimens before thermal cycling. The bond strength of Cesead Opaque Primer was greatest. And after 2,000 thermal cycles, the bond strengths between resin and cobalt-chromium alloy were decreased but the difference between thermal cycling 0 and 2,000 at Cesead Opaque primer and Metal Primer were not significant. This study indicated that Cesead Opaque Primer & Metal Primer is effective primers to obtain higher bond strength between heat cured denture base resin and cobalt-chromium alloy.

  • PDF

온성방법과 단면형태가 수종의 의치상 수리레진의 결합강도에 미치는 영향 (THE EFFECT OF PROCESSING METHOD AND SURFACE DESIGN ON THE TRANSVERSE STRENGTH OF REPAIRED DENTURE BASE RESIN)

  • 김강남;배태성;한중석
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.665-674
    • /
    • 1996
  • This study was designed to evaluate the effect of processing method and surface design on the transverse strength of repaired denture base resin. Three heat-cured denture base resins(Vertex, Lucitone, Lang), one cold-cured resin(Lang), and one light-cured resin(Dentacolor gingiva material) were used for repair purpose. The specimens for 3-point flexure test were fabricated by five processing methods such as self-curing, pressure pot, boiling water, processing, and light curing. Finally to evaluate the effect of surface designs for repaired resin, three surface designs(butt, bevel, inverse bevel) were tested. Within the limit of this study, following conclusions were drawn. 1. Lucitone denture base material showed highest flexural strength of $131.37{\pm}2.15MPa$, and there were significant differences in stength between Lucitone and other resins. 2. Between two different self curing methods, self curing repair resin, Lang, cured by pressure pot method showed highest flexural strength, $58.49{\pm}4.89MPa$. 3. Among the heat cured repair resins, maximum transverse strength value of $88.69{\pm}16.60MPa$ was recorded in Lucitone group cured by processing method. 4. Inverse bevel joint design showed significantly higher bond strength than butt joint group, Maximum bond strength was $59.36{\pm}1.33MPa$ in inverse bevel joint design group.

  • PDF

Physical properties and color stability of injection-molded thermoplastic denture base resins

  • Song, So-Yeon;Kim, Kyoung-Soo;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS. In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS. For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P<.05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION. Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.