• Title/Summary/Keyword: Bar-shaped

Search Result 149, Processing Time 0.024 seconds

Ultrastructural Study on the Thymus following the Administration of 5-Fluoruracil or Mitomycin (5-Fluorouracil 및 Mitomycin이 가슴샘의 미세구조에 미치는 영향)

  • Ko, Jeong-Sik;Ahn, E-Tay;Park, Kyung-Ho;Park, Dong-Boon;Kyung, Hong-Kee;Han, Young-Bok
    • Applied Microscopy
    • /
    • v.27 no.1
    • /
    • pp.13-30
    • /
    • 1997
  • The experiment was performed to study the morphological responses of the thymus of the mice, to antitumour agents (5-Fluorouracil or mitomycin C). Healthy adult mice weighing 25 gm each were divided into normal and experimental groups. 5-Fluorouracil (60 mg/kg) or Mitomycin-C $(400{\mu}g/kg)$ were injected subcutaneously to the animals every other day. Animals were sacrificed at 4 days and 7 days following the first injection. Pieces of the tissue taken from the thymus were prefixed with 2.5% paraformaldehyde-l.5% glutaraldehyde, followed by post-fixation with 1% osmium tetroxide. Ultrathin sections stained with uranyl acetate and lead citrate were observed with a JEM 100 CX-II electron microscope. The observed results were as follow: 1. Apoptoses of T-lymphocytes were observed more frequently in the thymus of the experimental groups than in those of a normal group. 2. In the experimental group, the plasma cells with distended cisternae of the granular endoplasmic reticulum and the eosinophile leukocytes were observed frequently. 3. In the experimental group, newly forming Hassall's corpurscles were observed frequently. 4. In the mitomycin-treated group, the epithelial reticular cells containing distended perinuclear cisternae, distended the granular endoplasmic reticula and pyknotic nuclei were observed in the cortico-medullary junctional area. 5. In the mitomycin-treated group, nuclear bodies with medium electron dense materials were often observed in the T lymphocyte. 6. In the 5-fluorouracil-treated groups, fused and dissolved tonofilament bundles and apoptotic bodies were observed in the some epithelial reticular cells in the medullary area. 7. In the 5-fluorouracil-treated groups, some elongated and bar-shaped lysosomes with electron lucent gap were often observed in the macrophages. 8. In the 5-fluorouracil-treated group, membrane complex of the smooth endoplasmic reticulum were ofen observed in the macrophage. From the above results, it was suggested that 5-fluorouracil or mitomycin could induce rapid involution of the thymus, and disturb maturation and differentiation of T lymphocytes, and, in turn, supress immunity.

  • PDF

Petrochemistry of the Soyeonpyeong titaniferous iron ore deposits, South Korea (소연평도 함티타늄 자철광상의 암석지구화학적 연구)

  • Kim, Kyu Han;Lee, Jung Eun
    • Economic and Environmental Geology
    • /
    • v.27 no.4
    • /
    • pp.345-361
    • /
    • 1994
  • Lens shaped titanomagnetite ore bodies in the Soyeonpyeong iron mine are embedded in amphibolites, which were intruded into Precambrian metasediments such as garnet-mica schist, marble, mica schist, and quartz schist. Mineral chemistry, K-Ar dating and hydrogen and oxygen stable isotopic analysis for the amphibolites and titanomagnetite ores were conducted to interpret petrogenesis of amphibolite and ore genesis of titanomagnetite iron ore deposits. Amphibolites of igneous origin have unusually high content of $TiO_2$, ranging from 0.94 to 6.39 wt.% with an average value of 4.05 wt.%. REE patterns of the different lithology of the amphibolite show the similar trend with an enrichment of LREE. Amphiboles of amphibolites are consist mainly of calcic amphiboles such as ferro-hornblende, tschermakite, ferroan pargasite, and ferroan pargasitic hornblende. K-Ar ages of hornblende from amphibolite and gneissic amphibolite were determined as $440.04{\pm}6.39Ma$ and $351.03{\pm}5.21Ma$, respectively. This indicates two metamorphic events of Paleozoic age in the Korean peninsula which are correlated with Altin orogeny in China. The titanomagnetite mineralization seems to have occurred before Cambrian age based on occurrence of orebodies and ages of host amphibolites. The Soyeonpyeong iron ores are composed mainly of titanomagnetite, ilmenite, and secondary minerals such as ilmenite and hercynite exsolved in titanomagnetite. The temperature and the oxygen fugacity estimated by the titanomagnetite-ilmenite geothermometer are $500{\sim}600^{\circ}C$ (ave. $550^{\circ}C$) and about $2{\pm}10^{-23}bar$, respectively. Hornblendes from ores and amphibolites which responsible for magnetite ore mineralization, have a relatively homogeneous isotopic composition ranging from +0.8 to +3.9 ‰ in ${\delta}^{18}O$ and from -87.8 to -113.3 ‰ in ${\delta}D$. The calculated oxygen and hydrogen isotopic compositions of the fluids which were in equilibrium with hornblende at $550^{\circ}C$, range from 2.8 to 5.9‰ in ${\delta}^{18}O_{H2O}$ and from -60.41 to -81.31 ‰ in ${\delta}D_{H2O}$. The ${\delta}^{18}O_{H2O}$ value of magnetite ore fluids are in between +6.4 to + 7.9 ‰. All of these values fall in the range of primary magmatic water. A slight oxygen shift means that $^{18}O$-depleted meteoric water be acted with basic fluids during immiscible processes between silicate and titaniferous oxide melt. Mineral chemistry, isotopic compositions, and occurences of amphibolites and orebodies, suggest that the titanomagnetite melt be separated immisciblely from the titaniferous basic magma.

  • PDF

A Micro Fluxgate Magnetic Sensor with Closed Magnetic Path (폐자로를 형성한 마이크로 플럭스게이트 자기 센서)

  • 최원열;황준식;강명삼;최상언
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.19-23
    • /
    • 2002
  • This paper presents a micro fluxgate magnetic sensor in printed circuit board (PCB). In order to observe the effect of the closed magnetic path, the magnetic cores of rectangular-ring and two bars were each fabricated. Each fluxgate sensor consists of five PCB stack layers including one layer magnetic core and four layers of excitation and pick-up coils. The center layer as a magnetic core is made of a Co-based amorphous magnetic ribbon with extremely high DC permeability of ~100,000. Four outer layers as an excitation and pick-up coils have a planar solenoid and are made of copper foil. In case of the fluxgate sensor having the rectangular-ring shaped core, excellent linear response over the range of -100 $\mu$T to + 100 $\mu$T is obtained with 540 V/Tsensitivity at excitation square wave of 3 $V_{p-p}$ and 360 KHz. The chip size of the fabricated sensing element is $7.3 \times 5.7\textrm{mm}^2$. The very low power consumption of ~8 mW was measured. This magnetic sensor is very useful for various applications such as: portable navigation systems, telematics, VR game and so on.n.

  • PDF

A simple technique for repositioning of the mandible by a surgical guide prepared using a three-dimensional model after segmental mandibulectomy

  • Funayama, Akinori;Kojima, Taku;Yoshizawa, Michiko;Mikami, Toshihiko;Kanemaru, Shohei;Niimi, Kanae;Oda, Yohei;Kato, Yusuke;Kobayashi, Tadaharu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.16.1-16.6
    • /
    • 2017
  • Background: Mandibular reconstruction is performed after segmental mandibulectomy, and precise repositioning of the condylar head in the temporomandibular fossa is essential for maintaining preoperative occlusion. Methods: In cases without involvement of soft tissue around the mandibular bone, the autopolymer resin in a soft state is pressed against the lower border of the mandible and buccal and lingual sides of the 3D model on the excised side. After hardening, it is shaved with a carbide bar to make the proximal and distal parts parallel to the resected surface in order to determine the direction of mandibular resection. On the other hand, in cases that require resection of soft tissue around the mandible such as cases of a malignant tumor, right and left mandibular rami of the 3D model are connected with the autopolymer resin to keep the preoperative position between proximal and distal segments before surgical simulation. The device is made to fit the lower border of the anterior mandible and the posterior border of the mandibular ramus. The device has a U-shaped handle so that adaptation of the device will not interfere with the soft tissue to be removed and has holes to be fixed on the mandible with screws. Results: We successfully performed the planned accurate segmental mandibulectomy and the precise repositioning of the condylar head by the device. Conclusions: The present technique and device that we developed proved to be simple and useful for restoring the preoperative condylar head positioning in the temporomandibular fossa and the precise resection of the mandible.

Comparison analysis of fracture load and flexural strength of provisional restorative resins fabricated by different methods (제작방법에 따른 임시 수복용 레진의 파절강도 및 굴곡강도에 관한 연구)

  • Cho, Won-Tak;Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.225-231
    • /
    • 2019
  • Purpose: This study was undertaken to compare fracture and flexural strength of provisional restorative resins fabricated by additive manufacturing, subtractive manufacturing, and conventional direct technique. Materials and methods: Five types of provisional restorative resin made with different methods were investigated: Stereolithography apparatus (SLA) 3D printer (S3Z), two digital light processing (DLP) 3D printer (D3Z, D3P), milling method (MIL), conventional method (CON). For fracture strength test, premolar shaped specimens were prepared by each method and stored in distilled water at $37^{\circ}C$ for 24 hours. Compressive load was measured using a universal testing machine (UTM). For flexural strength test, rectangular bar specimens ($25{\times}2{\times}2mm$) were prepared by each method according to ISO 10477 and flexural strength was measured by UTM. Results: Fracture strengths of the S3Z, D3Z, and D3P groups fabricated by additive manufacturing were not significantly different from those of MIL and CON groups (P>.05/10=.005). On the other hand, the flexural strengths of S3Z, D3P, and MIL groups were significantly higher than that of CON group (P<.05), but the flexural strength of D3Z group was significantly lower than that of CON group (P<.05). Conclusion: Within the limitation of our study, provisional restorative resins made from additive manufacturing showed clinically comparable fracture and flexural strength as those made by subtractive manufacturing and conventional method.

Inexpensive Visual Motion Data Glove for Human-Computer Interface Via Hand Gesture Recognition (손 동작 인식을 통한 인간 - 컴퓨터 인터페이스용 저가형 비주얼 모션 데이터 글러브)

  • Han, Young-Mo
    • The KIPS Transactions:PartB
    • /
    • v.16B no.5
    • /
    • pp.341-346
    • /
    • 2009
  • The motion data glove is a representative human-computer interaction tool that inputs human hand gestures to computers by measuring their motions. The motion data glove is essential equipment used for new computer technologiesincluding home automation, virtual reality, biometrics, motion capture. For its popular usage, this paper attempts to develop an inexpensive visual.type motion data glove that can be used without any special equipment. The proposed approach has the special feature; it can be developed as a low-cost one becauseof not using high-cost motion-sensing fibers that were used in the conventional approaches. That makes its easy production and popular use possible. This approach adopts a visual method that is obtained by improving conventional optic motion capture technology, instead of mechanical method using motion-sensing fibers. Compared to conventional visual methods, the proposed method has the following advantages and originalities Firstly, conventional visual methods use many cameras and equipments to reconstruct 3D pose with eliminating occlusions But the proposed method adopts a mono vision approachthat makes simple and low cost equipments possible. Secondly, conventional mono vision methods have difficulty in reconstructing 3D pose of occluded parts in images because they have weak points about occlusions. But the proposed approach can reconstruct occluded parts in images by using originally designed thin-bar-shaped optic indicators. Thirdly, many cases of conventional methods use nonlinear numerical computation image analysis algorithm, so they have inconvenience about their initialization and computation times. But the proposed method improves these inconveniences by using a closed-form image analysis algorithm that is obtained from original formulation. Fourthly, many cases of conventional closed-form algorithms use approximations in their formulations processes, so they have disadvantages of low accuracy and confined applications due to singularities. But the proposed method improves these disadvantages by original formulation techniques where a closed-form algorithm is derived by using exponential-form twist coordinates, instead of using approximations or local parameterizations such as Euler angels.

The Effect of Water Immersion on the Surface Strength and the Flexural Strength of the Acrylic Resin for Occlusal Appliances (교합장치용 아크릴레진의 표면경도와 굴곡강도에 대한 침수의 영향)

  • Lee, Hoy-Youn;Im, Yeong-Gwan;Kim, Byung-Gook;Lim, Hoi-Soon;Kim, Jae-Hyung
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.75-81
    • /
    • 2010
  • By repeating nocturnal bruxism occlusal appliance's wearing condition that is used to cure temporomandibular disorders into the vitro experiment, research aims to find out how moisture infiltrated and drying cycle process affects on the surface microhardness of the resin for occlusal appliance and flexural strength. By utilizing resin for occlusal appliance which is the main component of poly methyl methacrylate, bar shaped sample was produced. For the resin sample utilized as the controlled group 1, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, the resin sample of the controlled group 2 was maintained in a dry condition for 7 days in the normal temperature. After that, each sample's surface microhardness and flexural strength were measured. For the resin sample that is utilized as the experimental sample, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, it was inundated for 8 hours a day and dried in the normal temperature for 16 hours with the continuous process of moisture infiltration and dry cycle process for 30 days. During this cycle process, sample's surface and flexural strength were measured in the 1st day, 7th day, and 30th day. Then, it was statistically analyzed to find out the difference of controlled and experiment group's surface microhardness and flexural strength. Results are 1. For the experimental and controlled group's surface microhardness of the resin for the occlusal appliance, it did not show any significant differences after moisture infiltration and dry cycle process repetition. 2. In case of the flexural strength for resin for the occlusal appliance, experimental group with moisture infiltration and dry cycle for 30 day process had greater effect than the experimental group at the 1st day and controlled group These results can be considered to be utilized from the patients of the temporomandibular disorders towards occlusal appliance used and maintained method.

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

A study on the awareness about "Dong-YI(東夷)" in Confucianism scripture (유교경전의 동이 인식에 관한 연구 - 13경 및 그 주석서를 중심으로 -)

  • Ham, HyunChan
    • The Journal of Korean Philosophical History
    • /
    • no.30
    • /
    • pp.123-159
    • /
    • 2010
  • Dongyi (Chinese: 東夷; pinyin: $D{\bar{o}}ngy{\acute{i}}$; Wade-Giles: Tung-yi; literally "eastern 'barbarians'") was a collective term for people in eastern China and in the east of China. People referred to as Dongyi vary across the ages. The early Dongyi culture was one of earliest neolithic cultures in China. According to the earliest Chinese record, Zuo Zhuan, the Shang Dynasty was attacked by King Wu of Zhou, while attacking Dongyi, and collapsed afterwards Dongyi culture was one of the oldest neolithic cultures in China. Some Chinese scholars extend the historical use of Dongyi to prehistoric times, according to this belief, the neolithic culture correlates to Houli culture, Beixin culture, Dawenkou culture, Longshan culture and Yueshi culture, five evolutionary phases. Deliang He, thinks that Dongyi culture used to be one of the leading cultures in neolithic China. The writing system of Dongyi was one of the oldest writing systems in neolithic China. There are opinions that the 20 pictogram characters discovered in a Dongyi tomb (山東?縣大汶口墓葬) in Shangdong indictates some of the characters found, like "旦, 越, 斤, 皇, 封, 酒, 拍, ?", are still used in Chinese characters. There are also opinions that Dongyi people were the inventor of arrows. Some classic Chinese history records like Zuo Zhuan, Shuowen Jiezi, Classic of Rites, all have some similar records about this. [3][4] The legendary god of archery in Chinese mythology, Houyi, could also be a Dongyi leader. Based on archeology findings, Dongyi people's ancestral worship totem is bird-shaped. In the meantime, The fundamental thing that Koreans should do is to find out Korean identy. Koreans cannot achieve their goals unless they enforce politics economics, educations, etc. in harmony with their own identity. However, some people say that Koreans do not have any dentity on the grounds that there is no Korean traditional thought. This view is, however, absolutely absurd because it is impossible for a nation to exist for oner five thousand years without having it's own native characteristics. The most essential thought in Korean identity is Confucius' In(仁). In is originated from Yi(夷) or Yi-jok(夷族)'s heart. On this account, Confucius' In can be a precious thought to Korean people who have been suffering from many problem caused by the absence of Korean identity. If Korean could understand their original characteristics and if Korean couldrealize that their original characteristics are Confucius' In, then our culture and identity recovery of though may maximize efficiency of country and society development.