• Title/Summary/Keyword: Bandwidth measurement

Search Result 576, Processing Time 0.031 seconds

Implementation and Estimation of the LUTS Diagnosis System for Home Health Care (홈 헬스케어에 적용 가능한 하부요로계 폐색 모니터링 시스템 구현 및 평가)

  • Jeong Do-Un;Chung Wan-Young;Jeon Gye-Rork
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.697-700
    • /
    • 2006
  • A sensor and measuring system were implemented to measure two signals that uroflow and urophonography during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the implemented system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter the most influence of effect according to occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253\sim282Hz$ of the urophonography signal.

  • PDF

Method on DTN Performance Acceleration and Packet Loss Minimization for Transfer Efficiency Maximizing (전송효율성 극대화를 위한 DTN 성능 가속 및 병목구간 패킷손실 최소화 방안)

  • Park, Jong-Seon;Noh, Min-Ki
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.37-43
    • /
    • 2018
  • Science DMZ is a network architecture that considers complicated network components such as dedicated network, DTN, and minimum security policy to maximize transfer efficiency. And DTN tuning is an essential component to take full advantage of Science DMZ's available bandwidth. In addition, tuning of network system should be performed concurrently to minimize packet loss due to network bottleneck. In this paper, we propose a tuning method of data transfer node and network system for maximizing transfer efficiency in Science DMZ network architecture. As a result of the performance measurement using the KREONET, the network performance after the DTN tuning shows 180% improvement than that of existing method without DTN tuning. In addition, performance of 9.4Gb/s was shown without loss of performance measurement after tuning network system applying shaping policy.

A Compact CPW-fed Antenna with Two Slit Structure for WLAN/WiMAX Operations (WLAN/WiMAX 대역에서 동작하는 두 개의 슬릿 구조를 갖는 CPW 급전방식 소형 안테나)

  • Kim, Woo-Su;Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.759-766
    • /
    • 2022
  • In this paper, we propose a multi-band small antenna with CPW(Coplanar Waveguide) feeding structure WLAN(Wireless Local Area Network) and WiMAX (Worldwide Interoperability for Microwave Access) bands. The proposed antenna is designed two slit in the modified monopole type radiator and FR-4 substrate, which is thickness 1.0 mm, and the dielectric constant is 4.4. The size of proposed antenna is 15.1 mm⨯16.41 mm, and total size of proposed antenna is 17.5 mm⨯16.4 mm. From the fabrication and measurement results, From the fabrication and measurement results, bandwidths of 439 MHz (2.06 to 2.499 GHz), 840 MHz (3.31 to 4.25) and 1,315 MHz (5.23 to 6.545 GHz) were obtained on the basis of -10 dB impedance bandwidth. Also, 3D radiation pattern characteristics of the proposed antenna are displayed and measured gains 2.24 dBi, 2.83 dBi, and 2.0 dBi shown in the three frequency band, respectively.

Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP (원전 증기발생기 와전류검사 장치의 전기적 특성 측정)

  • Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young;Lee, Tae-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.465-471
    • /
    • 2013
  • A steam generator in nuclear power plant is a heatexchager which is used to convert water into steam from heat produced in a nuclear reactor core, and the steam produced in steam generator is delivered to the turbine to generate electricity. Because of damage to steam generator tubing may impair its ability to adequately perform required safety functions in terms of both structural integrity and leakage integrity, eddy current testing is periodically performed to evaluate the integrity of tubes in steam generator. This assessment is normally performed during a reactor refueling outage. Currently, the eddy current testing for steam generator of nuclear power plant in Korea is performed in accordance with KEPIC & ASME Code requirements, the eddy current testing system is consists of remote data acquisition unit and data analysis program to evaluate the acquired data. The KEPIC & ASME Code require that the electrical properties of remote data acquisition unit, such as total harmonic distortion, input & output impedance, amplifier linearity & stability, phase linearity, bandwidth & demodulation filter response, analog-to-digital conversion, and channel crosstalk shall be measured in accordance with the KEPIC & ASME Code requirements. In this paper, the measurement requirements of electrical properties for eddy current testing instrument described in KEPIC & ASME Code are presented, and the measurement results of newly developed eddy current testing instrument by KHNP(Korea Hydro & Nuclear Power Co., LTD) are presented.

Development of Broadband Electromagnetic Wave Absorber for X-band Sensors in Double-layered Type Using Carbon

  • Choi, Chang-Mook;Kim, Dong-Il;Li, Rui;Choi, Dong-Han
    • Journal of Navigation and Port Research
    • /
    • v.30 no.9
    • /
    • pp.763-766
    • /
    • 2006
  • In this paper, the EM wave absorbers were designed and fabricated for X -band sensors using Carbon of dielectric material with CPE. The complex relative permittivity of samples is calculated by using measurement results of S-parameter. We simulated the double-layered type EM wave absorber with broad bandwidth using the measured complex relative permittivity by changing the thickness and layer, which was fabricated based on the simulated design The fabricated EM wave absorber consists of 1 mm first layer sheet facing metal with Carbon composition ratio 70 vol. % and 1.5 mm second layer sheet with Carbon composition ratio 60 vol. %. The measured results showed a good agreement to the simulated ones. It is found toot the optimized absorption ability of double-layered type EM wave absorber with thickness of 2.5 mm is higher than 10 dB from 7.8 GHz to 13.3 GHz.

Photonic-Assisted Reactive-Near-Field Analysis of a 3 dB-Tapered Ka-Band Array Antenna

  • Lee, Dong-Joon;Kang, Jeong-Jin;Kang, No-Weon;Kim, Wan-Sik;Park, Wee-Sang;Rothwell, Edward J.;Whitaker, John F.
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.1
    • /
    • pp.18-24
    • /
    • 2010
  • A Ka-band microstrip array antenna for wide-range detection of moving targets is analyzed through a photonicassisted reactive-near-field characterization technique. The antenna array employs a 3-dB-tapered feed network to suppress the sidelobe level while retaining a wide azimuth beamwidth for a wide detection range. The relative nearelectric field patterns of the array and its 3-dB-tapered feed lines have been measured using an electro-optic fieldmapping technique for minimally invasive millimeter-wave sensing. A number of typical limitations on the technique, involving bandwidth, low signal-modulation depth, and high laser-induced noise in high-frequency applications, have been overcome by suppressing the carrier portion of the optical interrogation beam.

The Measurement of Electromagnetic Waves caused by Surface Discharges of Solide Insulator at VHF Band Using an Antenna (안테나를 이용한 VHF대역에서 고체절연체의 연면방전에 기인한 방사전자파의 측정)

  • Kim, Ch.N.;Park, K.S.;Kim, K.C.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.219-223
    • /
    • 2001
  • In this paper, electromagnetic waves were measured in accordance with propagating the discharge when positive and negative DC high voltage was applied to needle-plane electrdes and plane-plane electrdes that solid dielectric was inserted between the electrodes. The radiated electromagnetic waves were investigated in bandwidth of VHF($30{\sim}230$[MHz]) using an biconical antenna. In needle-plane electrodes high electric field intensity is shown in both frequency band of 90(MHz) and 170[MHz], and gradually decreasing characteric is appeared at high frequency band. However high electric field intensity is shown in both 80[MHz] and 140[MHz] in case of plane-plane electrodes configuration. And over 150[MHz] frequency band, rapidly decreasing characteristic is shown. Moreover, electric field intensity of positive DC is about $5{\sim}10$[dB] higher than negative DC.

  • PDF

CMOS Linear Power Amplifier with Envelope Tracking Operation (Invited Paper)

  • Park, Byungjoon;Kim, Jooseung;Cho, Yunsung;Jin, Sangsu;Kang, Daehyun;Kim, Bumman
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • A differential-cascode CMOS power amplifier (PA) with a supply modulator for envelope tracking (ET) has been implemented by 0.18 ${\mu}m$ RF CMOS technology. The loss at the output is minimized by implementing the output transformer on a FR-4 printed circuit board (PCB). The CMOS PA utilizes the $2^{nd}$ harmonic short at the input to enhance the linearity. The measurement was done by the 10MHz bandwidth 16QAM 6.88 dB peak-to-average power ratio long-term evolution (LTE) signal at 1.85 GHz. The ET operation of the CMOS PA with the supply modulator enhances the power-added efficiency (PAE) by 2.5, to 10% over the stand-alone CMOS PA for the LTE signal. The ET PA achieves a PAE of 36.5% and an $ACLR_{E-UTRA}$ of -32.7 dBc at an average output power of 27 dBm.

Compact Folded Monopole Antenna Excited by a Conductor-Backed Coplanar Waveguide with Vias

  • Kim, Jin Hyuk;Hwang, Keum Cheol
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.534-537
    • /
    • 2013
  • A compact monopole antenna excited by a conductor-backed coplanar waveguide (CBCPW) is developed for wireless USB dongle applications. The proposed antenna has a compact dimension of $14mm{\times}47.4mm{\times}3.5mm$, which is suitable for a USB dongle housing. A slotted elliptical patch and a CBCPW with vertical vias are employed to achieve a further size reduction and an improved impedance bandwidth. The measurement result demonstrates that the fabricated antenna resonates from 2.25 GHz to 10.9 GHz, which covers all of the important wireless communication bands, including WiBro (2.3 GHz to 2.4 GHz), Bluetooth (2.4 GHz to 2.484 GHz), WiMAX (2.5 GHz to 2.7 GHz and 3.4 GHz to 3.6 GHz), satellite DMB (2.605 GHz to 2.655 GHz), 802.11b/g/a WLAN (2.4 GHz to 2.485 GHz and 5.15 GHz to 5.825 GHz), and ultra-wideband (3.1 GHz to 10.6 GHz) services. The radiation characteristics of the proposed antenna when attached to a laptop are tested to investigate the influence of the keypad and the LCD panel of the laptop.

Extended Sacrificial Bulk Micromachining Process and Its Application to the Fabrication of X-axis Single-crystalline Silicon Micro-gyroscope

  • Kim, Jong-Pal;Park, Sang-Jun;Kwak, Dong-Hun;Ko, Hyoung-Ho;Song, Tae-Yong;Setiadi, Dadi;Carr, William;Buss, James;Dancho, Dong-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1547-1552
    • /
    • 2003
  • In this paper, we present a planar single-crystalline silicon x-axis micro-gyroscope fabricated with a perfectly aligned vertical actuation combs on one silicon wafer, using the extended SBM technology. The fabricated x-axis micro-gyroscope has the resolution of 0.1 deg/sec, the bandwidth of 100 Hz. These research results allow integrating 6 axes inertial measurement (3 accelerations and 3 angular rates) on the same silicon substrate using the same process for the first time.

  • PDF