• Title/Summary/Keyword: Balloon Shape

Search Result 25, Processing Time 0.034 seconds

Terminal Myelocystocele : Pathoembryogenesis and Clinical Features

  • Lee, Ji Yeoun;Kim, Kyung Hyun;Wang, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.321-326
    • /
    • 2020
  • There has been confusion in the classification of terminal myelocystocele (TMCC) due to its diverse morphology and vague pathoembryogenesis. TMCC could be summarized as having the essential features of an elongated caudal spinal cord extruding out of the dorsal extraspinal space that fuses with the subcutaneous fat, which is in the shape of a trumpet-shaped cerebrospinal fluid-filled cyst. The extraspinal portion of the extruded spinal cord is nonfunctional. The morphological features suggest that TMCC is formed during secondary neurulation, specifically the failure of the degeneration of the secondary neural tube near the time of the terminal balloon. This review discusses the definition, as well as the clinical and surgical features, of TMCC with special emphasis on its pathoembryogenesis.

Changes of Blood Flow Characteristics due to Catheter Obstruction during the Coronary Angioplasty

  • Suh, Sang-Ho;Roh, Hyung-Woon;Kwon, Hyuck-Moon;Lee, Byoung-Kwon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Uses of catheters during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. Catheters in blood vessels cause pressure gradient rise and blood flow drop during the measurements. In this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter obstructions during the coronary angioplasty. The computer simulation models are generated by the data, which are measured by coronary angiogram, and the blood is treated as non-Newtonian fluid. The velocity, pressure, and wall shear stress variations are observed for the estimate of damages of blood vessel. This study is also extended to investigate the effects of stenotic vessel size, and shape and catheter size and location.

  • PDF

Comparison of Growth Characteristics of Tricholoma matsutake Mycelium Among the Types of Air Bubble Bioreactor (공기부양식 생물반응기의 형태별 송이균사의 생장특성 비교)

  • Lee, Wi-Young;Ahn, Jin-Kwon;Ka, Kang-Hyeon;Kwon, Young-Jin
    • The Korean Journal of Mycology
    • /
    • v.31 no.2
    • /
    • pp.89-93
    • /
    • 2003
  • In order to select suitable bioreactor type inhibiting cell stress during submerged culture of Tricholoma matsutake mycelium, the growth characteristics and ergosterol contents were investigated using the external-loop type of air-lift bioreactor (ETAB), balloon type of air bubble bioreactor (BTBB) and column type of air bubble bioreactor (CTBB). Dry weights of the T. matsutake in the BTBB, ETAB and CTBB were 12 g, 11.4 g, and 9.5 g per 1 litter, respectively. BTBB, ETAB and CTBB reached stagnant phases 16, 20, and 24 days after cultivation, respectively, The BTBB was more suitable for liquid culture of T. matsutake mycelium compared to other bioreactors owing to much mycelia product and short culture period. The ergosterol contents produced by the mycelium in the bioreactors were in sequence of BTBB, CTBB, and ETAB at every growth phase. BTBB might affect the mycelium on producing the smallest size of pellets. BTBB and CTBB got the mycelium precipitated and coagulated under operation of bioreactor sparser, whereas ETAB shown no effect of above phenomenon. A renovated bioreactor combined between a balloon shape of BTBB and an external-loop of ETAB was developed to enhance the efficiency of culture technique.

CAD Scheme To Detect Brain Tumour In MR Images using Active Contour Models and Tree Classifiers

  • Helen, R.;Kamaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.670-675
    • /
    • 2015
  • Medical imaging is one of the most powerful tools for gaining information about internal organs and tissues. It is a challenging task to develop sophisticated image analysis methods in order to improve the accuracy of diagnosis. The objective of this paper is to develop a Computer Aided Diagnostics (CAD) scheme for Brain Tumour detection from Magnetic Resonance Image (MRI) using active contour models and to investigate with several approaches for improving CAD performances. The problem in clinical medicine is the automatic detection of brain Tumours with maximum accuracy and in less time. This work involves the following steps: i) Segmentation performed by Fuzzy Clustering with Level Set Method (FCMLSM) and performance is compared with snake models based on Balloon force and Gradient Vector Force (GVF), Distance Regularized Level Set Method (DRLSE). ii) Feature extraction done by Shape and Texture based features. iii) Brain Tumour detection performed by various tree classifiers. Based on investigation FCMLSM is well suited segmentation method and Random Forest is the most optimum classifier for this problem. This method gives accuracy of 97% and with minimum classification error. The time taken to detect Tumour is approximately 2 mins for an examination (30 slices).

Retrievable Nitinol Stent for Treatment of Tuberculous Tracheobronchial Stenosis -A case report- (결핵성 기관-기관지 협착에서 제거형 니티놀 스텐트 삽입요법 -1례-)

  • Chung, Bong-Kyu;Kim, Kwang-Taik;Park, Sung-Min;Sun, Kyung;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.107-111
    • /
    • 2000
  • Although a tracheal stent can be an option for inoperable tracheal stenoses there still are some troublesome side effects including overgranulation from foreign body irritation restenosis and patient's discomfort associated with the procedure. We report a successful case of a retrievable stent made of self-expandable 'shape memory' metal and polyurethane in a 24 year old female patient with respiratory distress and tight stenosis in the trachea and left main bronchus, The stent was inserted following a balloon dilatation and was successfully removed on the 7th days after the procedure. She regained a normal active life without any repiratory symptoms and a follow-up of 8 months showed satisfactory results.

  • PDF

Reconstruction of esophageal stenosis that had persisted for 40 years using a free jejunal patch graft with virtual endoscopy assistance

  • Fujisawa, Daisuke;Asato, Hirotaka;Tanaka, Katsunori;Itokazu, Tetsuo;Kojya, Shizuo
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.178-181
    • /
    • 2020
  • In this report, we present a case in which good results were achieved by treatment using a free jejunal patch graft with virtual endoscopy (VE) assistance in a patient whose swallowing had failed to improve for 40 years after he mistakenly swallowed sulfuric acid, despite pectoralis major myocutaneous flap grafting and frequent balloon dilatation surgery. During the last 20 years, virtual computed tomography imaging has improved remarkably and continues to be used to address new challenges. For reconstructive surgeons, the greatest advantage of VE is that it is a noninvasive modality capable of visualizing areas inaccessible to a flexible endoscope. Using VE findings, we were able to visualize the 3-dimensional shape beyond the stenosis. VE can also help predict the area of the defect after contracture release.

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.

A Study on Phrygia Headgear (프리기아[Phrygia] 모자에 대한 연구)

  • Yi-Chang Youngsoo
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.4 s.94
    • /
    • pp.138-150
    • /
    • 2005
  • Phrygia headgear has an important meaning from the perspectives of costume history and cultural exchanges in ancient times. This study is to investigate the prototype of Phrygia headgear through analysis of its manufacturing methods and styles on the basis of prior studies on ancient sculptures and literatures conducted by European researchers and to examine its history and meanings. In these ways, this study will be helpful in understanding the importance of Phrygia headgear in cultural exchanges between the East and the West. Results of this study can be summarized as follows: Phrygia headgear was orn by eastern tribes, so it was a symbol of those from the east in ancient times. Phrygia headgear is frequently found in Greek artistic works of 5th to 4th century BC that depicted eastern tribes. Also, this headgear can be observed in artistic works for Mithras, Attis, or other gods. Since Phrygia headgear's shape is similar to that of Homer's helm, many researchers believe that it might be originated from Homer's helm. This headgear made of oxen scrotum(stierbeutel) or its surrounding skin has a long end at the top. This long end is round and drooping toward the front side. From such unique shape, we top. This long end is round and drooping toward the front side. From such unique shape, we top. This long end is round and drooping toward the front side. From such unique shape, we can draw a conclusion that Phrygia headgear was made of oxen scrotum and its surrounding skin. Dependingy on drooping patterns, there are various shapes, such as the round, tightly swollen one worn by Mithras, the tongue-shaped one found in Basilika S. Apolinare Nuovo's mosaic depicting three wise men, the balloon-shaped one frequently found in Greek vases depicting Scythian, and the one drooping to the side depicted in Alexandersarkophag. Further, some Phrygia headgear has covers for neck and ears. For example, Phrygia headgear worn by Persian Satrap tribe has such covers attached to the head part. Meanwhile, Phrygia headgear worn by Amazone tribe does not show such separate covers, Rather, one piece of oxen skin was tanned and finished to make such covers. Wearing Phrygia headgear can be interpreted in several ways. Use of animal's skin for wearing things is a unique aspect in ancient societies because they believed that wearing animal skin would give them power of the animal. Further, Phrygia headgear made of oxen scrotum was a symbol of reproductive power to women.

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

Plant let growth, leaf stomata, and photosynthesis of grape rootstock '5BB' as affected by inoculum density in bioreactor cultures (포도 왜성대목 '5BB'의 생물반응기 배양에서 접종밀도가 식물체 생장, 기공 및 광합성 특성에 미치는 영향)

  • Choi, Eun-Jung;Hahn, Eun-Joo;Paek, Kee-Yoeup
    • Journal of Plant Biotechnology
    • /
    • v.35 no.2
    • /
    • pp.127-132
    • /
    • 2008
  • In bioreactor cultures of plants, inoculum density is an important factor affecting growth and proliferation of the plantlets. To maximize shoot growth and proliferation of grape rootstock '5BB' in bioreactors, inoculum density varied at 15, 30, 45 and 60 single nodes in a 3-liter scale balloon type bioreactor, respectively and cultured for 40 days. Results suggested that the growth and the photosynthesis of the plantlet were greatly affected by inoculum density in the bioreactor. The inoculum density of 45 nodes resulted in the greatest growth (910.4 mg/shoot FW, 764.4 mg/root FW) followed by 30 nodes. $CO_2$ assimilation rate, stomatal conductance, transpiration rate of the plantlet were also highest at the inoculum density of 45 nodes. Significant reduces in shoot and root growth (426.5 mg/shoot FW, 248.4 mg/root FW) were observed at the inoculum density of 60 nodes. When the inoculum density decreased by 15 nodes, plantlets were malformed due to hyperhydricity, resulting in the highest transpiration rate and the lowest $CO_2$ assimilation rate. The plantlets stressed by the inoculum density at 15 nodes and 60 nodes showed larger number and irregular shape of stomata compared to the plantlets inoculated with 45 nodes.