• Title/Summary/Keyword: Balloon Catheter

Search Result 108, Processing Time 0.034 seconds

A Study on Usefulness of Balloon Cholangiography in Operating ERCP (ERCP 시술중 Balloon Cholangiography의 유용성에 관한 고찰)

  • Son, Soon-Yong
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.43-49
    • /
    • 1997
  • Purpose of this paper is to extend help for clinical application in balloon cholangiography on patients who have undergone endoscopic sphincterotomy, impacted stones of intrahepatic duct, and missed bile duct because of other diseases in operating endoscopic retrograde cholangiopancreatography. This study was done for the patients who had clinical signs of biliary diseases from January to December In 1996. We studied 45 patients who had endoscopic sphincterotomy, re-examination after interventional treatment of the endoscopic retrograde cholangiopancreatography, and uncertain diagnosis due to common bile duct and intrahepatic duct those are not filled with contrast media. Balloon cholangiography was performed in case of uncertain diagnosis while operating endoscopic retrograde cholangiopancreatography. First of all, we insert balloon catheter Into the working channel of treatment jejunofiberscope and remove treatment Jejunofiberscope after ballooning, and lastly take biliary tract X-ray after Injection and changing position of patient. The results of this study were as follows. (1) In classification of diseases, stones of gall bladder, those of common bile duct, and those of intrahepatic duct were 30 cases, fistula was 1 case. (2) In total cases of 45, only diagnosis were 25 cases, interventional treatment were 20 cases. (3) In case of interventional treatment, endoscopic sphincterotomy and endoscopic nasobiliary drainage, and stone removal were about the same, 7, 7, 6 respectively. Balloon cholangiography will be useful to prevent patients from having repeated and unnecessary studies for the cases above explained. It is considered that this study will be useful for clinical application in terms of reducing medical expenses, pain while examination, and consultation hours.

  • PDF

Removal of a Left Upper Lobar Bronchial Foreign Body Using Fogarty Catheter and Rigid Bronchoscope

  • Woo, Hyunjun;Kim, Seo Young;Kwon, Seong Keun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.1
    • /
    • pp.37-41
    • /
    • 2022
  • Airway foreign body aspiration in children can lead to accidental death, due to the foreign body itself or the removal procedure. Depending on its location, removal of the foreign body can be challenging. Here, we present a case of successful removal of a foreign body from the left upper lobar bronchus via ventilating bronchoscopy with a rigid bronchoscope and Fogarty arterial embolectomy catheter. Tracheobronchial foreign bodies in locations that are difficult to reach with forceps, due to an acute angle or the small diameter of the pediatric bronchial tree, can be effectively removed with a Fogarty arterial embolectomy catheter.

The Measurement of Ho-166 Absorbed Dose for the Endovascular Irradiation with a Balloon Angio Catheter Using a GafChromic Film (GafChromic 필름을 이용한 Ho-166 의 혈관내 방사선조사를 위한 선량분포 측정)

  • 강해진;조철우;박찬희;오영택;전미선;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The GafChromic film was used for the dosimetry of a balloon angio catheter filled with the radioisotope HO-166 for endovascular irradiation. The balloon angio catheter was 2 cm long and 3 mm in diameter when inflated. The isotope, Ho-166, was produced by the neutron bombardment using the research reactor in Korea Atomic Energy Research Insititute. Co-60 teletherapy beam was used for making H-D curve for the Gaf-Chromic film. The film dosimetry was measured with a videodensitometer. The radial dose distribution indicated that the absorbed dose dropped to about 20% of the surface dose at the 1 mm away from the balloon surface and at 5 mm position the dose decreased to below 1% of the surface dose. The result also shows that with the specific activity of Ho-l66, 250 mCi/ml it takes 230 seconds to deliver 1200 cGy to the region where is 1mm away from the balloon surface. The concentric isodose curves were also presented. The Ho-166 is an another alternative for endovascualr irradiation to prevent restenosis after PTCA (Percutaneous Trans Coronary Angioplasty)

  • PDF

Initial experience with Scepter Mini dual lumen balloon for embolization of cerebrovascular diseases

  • Muhammad U Manzoor;Ibrahim A. Almulhim;Abdullah A. Alrashed;Shorog Althubait;Abdulrahman Y. Alturki;Sultan M. Al-Qahtani
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.2
    • /
    • pp.175-181
    • /
    • 2023
  • Objective: Endovascular treatment of cerebrovascular diseases is often challenging due to small caliber, tortuous distal vessels. Several devices and techniques have evolved to overcome these challenges. Recently, a low profile dual lumen microballoon catheter, specifically designed for distal navigation is employed for neurovascular procedures. Due to its recent advent, scarce data is available on clinical utility and safety of Scepter Mini. The aim of this case series is to report our initial experience with Scepter Mini in the management of various cerebrovascular diseases. Methods: All interventional neurovascular cases performed using Scepter Mini between January 2020 till April 2021 were included. Data regarding patient demographics, procedural details and complications was retrospectively collected from patient's electronic medical record and procedure reports. Results: Total twelve embolization procedures were performed in eleven patients, including six brain arteriovenous malformation, two dural arteriovenous fistula, one vein of Galen malformation and three hyper-vascular glomus tumor embolizations. All procedures were successfully performed with adequate penetration of the embolic agent. Complete embolization was performed in six procedures, while intended partial embolization was performed in the rest of procedures. Scepter Mini was solely used in ten procedures, however in the other two embolization procedures it was used as an additional conjunct tool to complete the intended embolization. No balloon related complication was observed in any procedure. Conclusions: Scepter Mini dual lumen microballoon catheter is safe and feasible for delivery of liquid embolic agents for cerebrovascular embolization procedures.

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

Analysis of procedural performance after a pilot course on endovascular training for resuscitative endovascular balloon occlusion of the aorta

  • Sung Wook Chang;Dong Hun Kim;Dae Sung Ma;Ye Rim Chang
    • Journal of Trauma and Injury
    • /
    • v.36 no.1
    • /
    • pp.3-7
    • /
    • 2023
  • Purpose: As resuscitative endovascular balloon occlusion of the aorta (REBOA) is performed in an extremely emergent situation, achieving competent clinical practice is mandatory. Although there are several educational courses that teach the REBOA procedure, there have been no reports evaluating the impact of training on clinical practice. Therefore, this study is aimed to evaluate the effects of the course on procedural performance during resuscitation and on clinical outcomes. Methods: Patients who were managed at a regional trauma center in Dankook University Hospital from August 2016 to February 2018 were included and were grouped as precourse (August 2016-August 2017, n=9) and postcourse (September 2017- February 2018, n=9). Variables regarding injury, parameters regarding REBOA procedure, morbidity, and mortality were prospectively collected and reviewed for comparison between the groups. Results: Demographics and REBOA variables did not differ between groups. The time required from arterial puncture to balloon inflation was significantly shortened from 9.0 to 5.0 minutes (P=0.003). There were no complications associated with REBOA after the course. Mortality did not show any statistical difference before and after the course. Conclusions: The endovascular training for REBOA pilot course, which uses a modified form of flipped learning, realistic simulation of ultrasound-guided catheter insertion and balloon manipulation, and competence assessment, significantly improved procedural performance during resuscitation of trauma patients.

Surgical Technique thor the Removal of Deep Vein Thrombi of the Lower Extremities (하지 심부정맥 혈전의 외과적 제거)

  • 이상호;최준영;김성호;김병균;장인석;이정은;옥창대;김종우;나재범
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.402-406
    • /
    • 2002
  • The conventional surgery method of thrombectomy of venous thrombi from the deep veins of the lower extremity was the use of Forgarty balloon catheter. The catheter is inconvenient due to the presence of the balloon and prohibiting venous valves within the venous trees. With the use of a stone-forceps(Fig. 1), thrombi within iliofemoral vein could be easily removed without the obstacle of the valves because the instrument keeps valves open. This instrument is also useful in monitoring the back-flow from the iliac vein. Thrombi within the veins below the level of inguinal incision are removed successfully only by effective manual compression of the calf and thigh muscles. 1 recommend operating on the iliac vein first rather than the lower venous tree.

Successful Damage Control Resuscitation with Resuscitative Endovascular Balloon Occlusion of the Aorta in a Pediatric Patient

  • Heo, Yoonjung;Chang, Sung Wook;Kim, Dong Hun
    • Journal of Trauma and Injury
    • /
    • v.33 no.3
    • /
    • pp.170-174
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) is considered an emerging adjunct therapy for profound hemorrhagic shock, as it can maintain temporary stability until definitive repair of the injury. However, there is limited information about the use of this procedure in children. Herein, we report a case of REBOA in a pediatric patient with blunt trauma, wherein the preoperative deployment of REBOA played a pivotal role in damage control resuscitation. A 7-year-old male patient experienced cardiac arrest after a motor vehicle accident. After 30 minutes of cardiopulmonary resuscitation, spontaneous circulation was achieved. The patient was diagnosed with massive hemoperitoneum. REBOA was then performed under ongoing resuscitative measures. An intra-aortic balloon catheter was deployed above the supraceliac aorta, which helped achieved permissive hypotension while the patient was undergoing surgery. After successful bleeding control with small bowel resection for mesenteric avulsion, thorough radiologic evaluations revealed hypoxic brain injury. The patient died from deterioration of disseminated intravascular coagulation. Although the patient did not survive, a postoperative computed tomography scan revealed neither remaining intraperitoneal injury nor peripheral ischemia correlated with the insertion of a 7-Fr sheath. Hence, REBOA can be a successful bridge therapy, and this result may facilitate the further usage of REBOA to save pediatric patients with non-compressible torso hemorrhage.