• Title/Summary/Keyword: Background light

Search Result 723, Processing Time 0.027 seconds

A Study of Response Characteristics and False Counts in Optical Particle Counter (광학 입자 계수기의 응답특성 및 오계수에 관한 연구)

  • 안강호;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.547-554
    • /
    • 1992
  • Response characteristics and false counts of laser and white light optical particle counters (OPC) have been studied as a function of particle size using monodisperse polystylen laterx (PSL) particles. Theoretical light scattering calculations for He-Ne laser based counter have been compared with the experimental results and thus good agreements have been found. The light scattering intensity in monochromatic light shows an oscillatory character for the transparent and spherical particles of PSL due to Mie resonance. Because of this effect, the response of the LAS-X OPC showed almost same responses in the diameter ranges of 0.4mu.m to 0.6mu.m and 0.7mu.m to 1.0mu.m for PSL particles. A laser optical particle counter with high flow rate applied for clean room has been studied to identify the noise sources. Three different manufacturer's clean room optical particle counters alos have been tested to measure the background noise level.

The Effect of an Optical Clearing Agent on Tissue Prior to 1064-nm Laser Therapy

  • Youn, Jong-In
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.146-152
    • /
    • 2021
  • Background and Objectives Although lasers have been widely applied in tissue treatment, the light penetration depth in tissues is limited by the tissue turbidity and affected by its absorption and scattering characteristics. This study investigated the effect of using an optical clearing agent (OCA) on tissue to improve the therapeutic effect of 1064 nm wavelength laser light by reducing the heat generated on the skin surface and increasing the penetration depth. Materials and Methods A diode laser (λ = 1064 nm) was applied to a porcine specimen with and without OCA to investigate the penetration depth of the laser light and temperature distribution. A numerical simulation using the finite element method was performed to investigate the temperature distribution of the specimen compared to ex-vivo experiments using a thermocouple and double-integrating sphere to measure the temperature profile and optical properties of the tissue, respectively. Results Simulation results showed a decrease in tissue surface temperature with increased penetration depth when the OCA was applied. Furthermore, both absorption and scattering coefficients decreased with the application of OCA. In ex-vivo experiments, temperatures decreased for the tissue surface and the fat layer with the OCA, but not for the muscle layer. Conclusion The use of an OCA may be helpful for reducing surface heat generation and enhance the light penetration depth in various near-infrared laser treatments.

Parametric Studies of Pulsed Laser Deposition of Indium Tin Oxide and Ultra-thin Diamond-like Carbon for Organic Light-emitting Devices

  • Tou, Teck-Yong;Yong, Thian-Khok;Yap, Seong-Shan;Yang, Ren-Bin;Siew, Wee-Ong;Yow, Ho-Kwang
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.65-74
    • /
    • 2009
  • Device quality indium tin oxide (ITO) films are deposited on glass substrates and ultra-thin diamond-like carbon films are deposited as a buffer layer on ITO by a pulsed Nd:YAG laser at 355 nm and 532 nm wavelength. ITO films deposited at room temperature are largely amorphous although their optical transmittances in the visible range are > 90%. The resistivity of their amorphous ITO films is too high to enable an efficient organic light-emitting device (OLED), in contrast to that deposited by a KrF laser. Substrate heating at $200^{\circ}C$ with laser wavelength of 355 nm, the ITO film resistivity decreases by almost an order of magnitude to $2{\times}10^{-4}\;{\Omega}\;cm$ while its optical transmittance is maintained at > 90%. The thermally induced crystallization of ITO has a preferred <111> directional orientation texture which largely accounts for the lowering of film resistivity. The background gas and deposition distance, that between the ITO target and the glass substrate, influence the thin-film microstructures. The optical and electrical properties are compared to published results using other nanosecond lasers and other fluence, as well as the use of ultra fast lasers. Molecularly doped, single-layer OLEDs of ITO/(PVK+TPD+$Alq_3$)/Al which are fabricated using pulsed-laser deposited ITO samples are compared to those fabricated using the commercial ITO. Effects such as surface texture and roughness of ITO and the insertion of DLC as a buffer layer into ITO/DLC/(PVK+TPD+$Alq_3$)/Al devices are investigated. The effects of DLC-on-ITO on OLED improvement such as better turn-on voltage and brightness are explained by a possible reduction of energy barrier to the hole injection from ITO into the light-emitting layer.

Photoreversibility of Fruiting and Growth in Oriental Melon (Cucumis melo L.)

  • Hong, Sung-Chang;Kim, Jin-Ho;Yeob, So-Jin;Kim, Min-Wook;Song, Sae-Nun;Lee, Gyu-Hyun;Kim, Kyeong-Sik;Yu, Seon-Young
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.312-318
    • /
    • 2020
  • BACKGROUND: Photoreversibility, a reversion of the inductive effect of a brief red light pulse by a subsequent far red light pulse, is a property of photo responses regulated by the plant photoreceptor phytochrome B. Plants use photoreceptors to sense photo signal and to adapt and modify their morphological and physiological properties. Phytochrome recognizes red light and far red light and plays an important role in regulating plant growth and development. METHODS AND RESULTS: The reversal responses of growth and fruiting characteristics were investigated to increase the yield of oriental melon (Cucumis Melo L. var. Kumsargakieuncheon) by means of controlling light quality in a plastic house. Red (R:660nm) and far red (FR:730nm) lights were subsequently irradiated on the whole stems and leaves of the oriental melon plant during growing periods, using red and far red LEDs as light sources, from 9:00 PM daily for 15 minutes. The intensities of R and FR light were 0.322-0.430 μmol m-2s-1 and 0.250-0.366 μmol m-2s-1, respectively. Compared to R light irradiation, combination of R and FR light irradiation increased the length of internode, number of axillary stems, number of female flowers, and fruit number of oriental melons. The results of treatment with R were similar to R-FR-R light irradiation in terms of length of internode, number of axillary stems, number of female flowers, and number of fruits. When FR treatment was considered, R-FR and R-FR-R-FR light irradiation had similarities in responses. These reversal responses revealed that oriental melon showed a photoreversibility of growth characteristics, flowering, and fruiting. CONCLUSION: These results suggested the possibility of phytochrome regulation of female flower formation and fruiting in oriental melon. The fruit weight of the oriental melon was the heaviest with the R light irradiation, while the number of fruits was the highest with the FR light. With the FR light irradiation, the fruit weight was not significantly higher compared to that of the control. Meanwhile, the yield of oriental melon fruits increased by 28-36% according to the intensities of the FR light due to the increases of the number of fruits.

The Effect of Lightly Gripping a Cane on Sit-to-stand Transfer in Post-stroke Patients

  • Choi, Young-eun;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.54-59
    • /
    • 2017
  • Background: Light touch cue is a sensory input that could potentially help in the control of posture. The immediate stimulatory effect of light touch cues using a cane during gait is associated with postural stability. This strategy can help post-stroke individuals regain their ability to perform the sit-to-stand (STS) transfer safely. Objects: The effects of light grip on postural control during the STS transfer in post-stroke subjects were investigated. Methods: Eleven participants (6 men, 5 women) with hemiplegia due to stroke were recruited in the study. The subjects with hemiparesis performed STS transfer in three randomly assigned conditions (1) without a cane (2) light grip with a cane (3) strong grip with a cane. Results: The difference in weight-bearing distribution between the left and right feet, when the subjects were instructed to stand up, was $52.73{\pm}2.13%$ without a cane, $42.75{\pm}3.26%$ with a strong grip, and $43.00{\pm}2.55%$ with a light grip (p<.05). The rate of rise in force indicates the peak power provided by subjects during their STS transfers. The rate of rise in force was statistically significantly lower without a cane than that with a light grip or a strong grip (p<.05). The subjects' centers of pressure sway on the mediolateral side during STS transfers statistically significantly declined with a light grip or a strong grip when compared to those without a cane (p<.05). Conclusion: When the subjects with hemiparesis used a cane during STS transfers, their duration, center of pressure sway, and difference in weight-bearing distribution were all reduced. The subjects also exhibited similar results during STS transfers with a cane gripped lightly. This result may provide guidelines for the use of assistive devices when patients with hemiparesis practice STS transfers in clinical settings.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

Analysis of Lateral Inhibitive-Function and Verification of Local Light Adaptive-Mechanism in a CMOS Vision Chip for Edge Detection (윤곽검출용 CMOS 시각칩의 수평억제 기능 해석 및 국소 광적응 메커니즘에 대한 검증)

  • Kim, Jung-Hwan;Park, Dae-Sik;Park, Jong-Ho;Kim, Kyoung-Moon;Kong, Jae-Sung;Shin, Jang-Kyoo;Lee, Min-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.57-65
    • /
    • 2003
  • When a vision chip for edge detection using CMOS process is designed, there is a necessity to implement local light adaptive-function for detecting distinctive features of an image at a wide range of light intensities. Local light adaptation is to achive the almost same output level by changing the size of receptive-fields of the local horizontal cell layers according to input light intensities, based on the lateral inhibitive-function of the horizontal cell. Thus, the almost same output level can be obtained whether input light intensities are much or less larger than background. In this paper, the horizontal cells using a resistive network which consists of p-MOSFETs were modeled and analyzed, and the local light adaptive-mechanism of the designed vision chip using the resistive network was verified.

A Comparative Study on Light and Space in the Stage Designs of Tristan und Isolde - Focusing on the Experiments and design projects by Max Keller - (트리스탄과 이졸데의 무대디자인에 적용된 빛과 공간의 비교분석 - 막스 켈러의 실험과 디자인 프로젝트를 중심으로 -)

  • Kim, Jong-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.3-10
    • /
    • 2009
  • The relationship between light and space is fundamental In an opera stage design. In contemporary stage design, light, color and space themselves became one of tile most important elements to express and symbolize the content of the opera. This was very different compared to the primitive and medieval opera stage design in the past. The designer tried to represent the same periodical background of the opera with exact replica of the buildings as well as costumes. In comtemporary performance art, light became one the most important aspects in design. Max Keller is one of the living pioneers in stage lighting design. This thesis that is based on his lighting experiments and projects attempts to examine how contemporary stage design and light are applied and what kind of characteristics they have. One of the Wagner's opera, "Tristan und Isolde" was selected to be further analyzed. Three different "Tristan und Isolde" opera stage designs were carefully studied in terms of how three designs are differently constructed for specific same contents of the opera. This sort of comparison study is crucial when there is a strict parameter that is the opera itself. It was found that three opera stages have very different stage designs and unique ways of expressing the opera flow and contents. However, in some parts, very similar lightings were used. This sort of multi-disciplinary study can be helpful to re-think the interior environment by applying light as a fundamental medium.

Inorganic Nanoparticles for Near-infrared-II Fluorescence Imaging (근적외선-II 형광 이미징을 위한 무기 나노입자)

  • Park, Yong Il
    • Applied Chemistry for Engineering
    • /
    • v.33 no.1
    • /
    • pp.17-27
    • /
    • 2022
  • Fluorescence imaging is widely used to image cells or small animals due to its high temporal and spatial resolution. Because conventional fluorescence imaging uses visible light, the penetration depth of light within the tissue is low, phototoxicity may occur due to visible light, and the detection sensitivity is lowered due to interference by background autofluorescence. In order to overcome this limitation, long-wavelength light should be used, and fluorescence imaging using near-infrared-I (NIR-I) in the region of 700~900 nm has been developed. To further improve imaging quality, researchers are interested in using a longer wavelength light, near-infrared-II (NIR-II) ranging from 1000 to 1700 nm. In the NIR-II region, light scattering is further minimized, and the penetration depth of light in the tissue is improved up to about 10 mm, and autofluorescence of the tissue is reduced, enabling high sensitivity and resolution fluorescence imaging. In this review, among various NIR-II fluorescence imaging probes, inorganic nanoparticle-based probes with excellent photostability and easily tunable emission wavelength were described, focusing on single-walled carbon nanotubes, quantum dots, and lanthanide nanoparticles.

Artificial Light Sources Influence Cherry Tomato (Lycopersicon esculentum var. cv. 'CF Jelly') Growth and Development (인공광원이 방울토마토(Lycopersicon esculentum var. cv. 'CF Jelly') 생육에 미치는 영향)

  • Jeong-Wook Heo;Jeong-Hyun Baek;Young-Sin Hong
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.4
    • /
    • pp.245-251
    • /
    • 2022
  • BACKGROUND: Selection an suitable light source is essential in the year-round production of horticultural crops in closed production systems such as plant factory with controlled environments. This study was investigated to confirm the effects of artificial light sources on growth of cherry tomato'CF Jelly'(Lycopersicon esculentum var.) under high-pressure sodium lamps (HPS), metal-halide lamps (MH), and LEDs. METHODS AND RESULTS: Light intensity of the light sources was controlled at 220±30 µmol/m2/s with 12 hrs of photoperiod for a day. Flower development was significantly faster in HPS and MH treatments compared to the LEDs. There was no significant difference between the leaf number and leaf shape under the HPS and MH treatments. Reproductive growth of cherry tomato was significantly promoted by the LEDs treatment of blue plus red lights. Fruit yield per plant also increased under the LEDs compared to the others. CONCLUSION(S): Growth, flowering, and fruit setting of the cherry tomato were accomplished by the artificial lights under plant factory conditions. The HPS treatment showed negative effect on fruit quality in terms of blossom-end rot incidence compared to the LEDs or MH treatment. Effect of the LEDs on promotion of fruit weight and yield was also proved. Additional research should be carried out for improving sugar metabolism or decreasing disease in the fruits under plant factory system using only artificial lights.