• Title/Summary/Keyword: Background counts

Search Result 210, Processing Time 0.026 seconds

Monotonic and Parallelizable Algorithm for Simultaneous Reconstruction of Activity/Attenuation using Emission data in PET

  • Kim, Seung-Gu
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.1
    • /
    • pp.299-309
    • /
    • 2001
  • In PET(Positron Emission Tomography), it is necessary to use transmission scan data in order to estimate the attenuation map. Recently, there are several empirical studies in which one might be able to estimate attenuation map and activity distribution simultaneously with emissive sinogram alone without transmission scan. However, their algorithms are based on the model in which does not include the background counts term, and so is unrealistic. If the background counts component has been included in the model, their algorithm would introduce non-monotonic reconstruction algorithm which results in vain in practice. in this paper, we develop a monotonic and parallelizable algorithm for simultaneous reconstruction of both characteristics and present the validity through some simulations.

  • PDF

Quantitative Analysis of Distribution of the Gastrointestinal Tract Eosinophils in Childhood Functional Abdominal Pain Disorders

  • Lee, Eun Hye;Yang, Hye Ran;Lee, Hye Seung
    • Journal of Neurogastroenterology and Motility
    • /
    • v.24 no.4
    • /
    • pp.614-627
    • /
    • 2018
  • Background/Aims Although functional abdominal pain disorders (FAPDs) are common in children, the accurate pathogenesis of FAPDs is not known yet. Micro-inflammation, particularly tissue eosinophilia of gastrointestinal (GI) tract, has been suggested as the pathophysiology observed in several GI disorders. We aimed to evaluate eosinophilic infiltration throughout the entire GI tract in children with FAPDs, compared to those with inflammatory bowel diseases (IBD) and to normal reference values. Methods We included 56 children with FAPDs, 52 children with Crohn's disease, and 23 children with ulcerative colitis. All subjects underwent esophagogastroduodenoscopic and colonoscopic examination with biopsies. Tissue eosinophil counts were assessed in 10 regions throughout the GI tract. Results Eosinophil counts of the gastric antrum, duodenum, terminal ileum, cecum, and ascending colon were significantly higher in children with FAPDs compared to normal reference values. Eosinophil counts of the stomach and the entire colon were observed to be significantly higher in children with IBD than in those with FAPDs. Even after selecting macroscopically uninvolved GI segments on endoscopy in children with IBD, eosinophil counts of the gastric body, cecum, descending colon, sigmoid colon, and the rectum were also significantly higher in children with IBD than those with FAPDs. Conclusions Significantly high eosinophil counts of the stomach and colon were observed in the order of IBD, followed by FAPDs, and normal controls, regardless of endoscopically detected macroscopic IBD lesions in children. This suggests some contribution of GI tract eosinophils in the intrinsic pathogenesis of FAPDs in children.

ON THE BACKGROUND-SUBTRACTED INTENSITY (백그라운드 제거후 신호의 세기에 대하여)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.

Effects of Acupuncture and Electroacupuncture on the Doublecortin, PSA-NCAM and pCREB Expression in the Brain of Spontaneously Hypertensive Rats (침(鍼) 및 전침(電鍼)이 SHR 대뇌(大腦)에서 Doublecortin, PSA-NCAM, pCREB 양성 신경세포에 미치는 영향)

  • Park, Jung-hwan;Lee, Jae-dong;Kim, Chang-hwan
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.61-81
    • /
    • 2004
  • Background and Objective : The aim of this study was to investigate the effects of acupuncture and electroacupuncture on the DCX, PSA-NCAM, and pCREB expression in the brain of spontaneously hypertensive rats(SHR). Materials and Methods : SHR were divided into five groups: control group, acupuncture group, 2Hz electroacupuncture(EA) group and 100Hz EA group. We evaluated the changes of the DCX, PSA-NCAM, and pCREB positive cells using immunohistochemical method. In the olfactory bulb, we investigate the optical densities of the immunoactive cells. In the dentate gyrus and the piriform cortex, we count the immunoactive cells under the $100{\times}$ visual field optical microscope. Results : 1. The optical densities of DCX-positive cells in the subependymal zone were significantly decreased in all groups, compared to the control group. 2. The counts of DCX-positive cells in the dentate gyrus were significantly increased in all groups, compared to the control group. The counts of DCX-positive cells in the piriform cortex were significantly increased in the acupuncture and 100Hz EA group, compared to the control group. 3. The optical densities of PSA-NCAM-positive cells in the subependymal zone were significantly decreased in the acupuncture and 2Hz EA group, compared to the control group. 4. The counts of PSA-NCAM-positive cells in the dentate gyrus and the piriform cortex were significantly increased in all group, compared to the control group. 5. The counts of pCREB-positive cells in the dentate gyrus were significantly increased in all groups, compared to the control group. The counts of pCREB-positive cells in the piriform cortex were significantly increased in the acupuncture and 100Hz EA group, compared to the control group. Conclusion : We conclude that acupuncture and EA may affect neuronal cell proliferation, differentiation and plasticity in the brain.

  • PDF

Usefulness of Image Registration in Brain Perfusion SPECT (Brain Perfusion SPECT에서 Image Registration의 유용성)

  • Song, Ho-June;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • Purpose: The brain perfusion SPECT is the examination which is able to know adversity information related brain disorder. But brain perfusion SPECT has also high failure rates by patient's motions. In this case, we have to use two days method and patients put up with many disadvantages. We think that we don't use two days method in brain perfusion SPECT, if we can use registration method. So this study has led to look over registration method applications in brain perfusion SPECT. Materials and Methods: Jaszczak, Hoffman and cylindrical phantoms were used for acquiring SPECT image data on varying degree in x, y, z axes. The phantoms were filled with $^{99m}Tc$ solution that consisted of a radioactive concentration of 111 MBq/mL. Phantom images were acquired through scanning for 5 sec long per frame by using Triad XLT9 triple head gamma camera (TRIONIX, USA). We painted the ROI of registration image in brain data. So we calculated the ROIratio which was different original image counts and registration image counts. Results: When carring out the experiments under the same condition, total counts differential was from 3.5% to 5.7% (mean counts was from 3.4% to 6.8%) in phantom and patients data. In addition, we also run the experiments in the double activity condition. Total counts differential was from 2.6% to 4.9% (mean counts was from 4.1% to 4.9%) in phantom and patients data. Conclusion: We can know that original and registration data are little different in image analysis. If we use the image registration method, we can improve disadvantage of two days method in brain perfusion SPECT. But we must consider image registration about the distance differences in x, y, z axes.

  • PDF

Attenuation of Background Molecular Ions and Determination of Isotope Ratios by Inductively Coupled Plasma Mass Spectrometry at Cool Plasma Condition

  • 박창준
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.7
    • /
    • pp.706-710
    • /
    • 1997
  • Isotope ratios of K, Ca, Cr and Fe are measured at cool plasma condition generated using high carrier flow rate and relatively low RF power of 900 W. Background molecular ions are suppressed to below 100 counts which give isobaric interference to the analytes. The background ions show different attenuation characteristics at increased carrier flow rate and hence for each element different carrier flow rate should be used to measure isotope ratios without isobaric interference. Isotope ratios are measured at both scan and peak-hopping modes and compared with certified or accepted ratios. The measured isotope ratios show some mass discrimination against low mass due to low ion energy induced from a copper shield to eliminate capacitive coupling of plasma with load coil.

Background Reduction for the ${\gamma}$-Ray Spectrometry of Environmental Radioactivity (환경방사능의 감마선 분광분석을 위한 백그라운드 소멸)

  • Seo, Bum Kyoung;Lee, Kil Yong;Yoon, Yoon Yeol;Lee, Dae Won
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.212-220
    • /
    • 2001
  • This study was performed to establish the analytical method of radium and radon in various environmental samples with the ${\gamma}$-ray spectrometry. The major problem in the measurements of low level ${\gamma}$-ray, such as environmental radioactivity, is the fluctuation of ${\gamma}$-ray background spectrum. To overcome this problem, a nitrogen gas was filled up in the detector chamber to reduce the background counts due to airborne radioactivities, i.e., $^{214}Pb$ and $^{214}Bi$, the daughters of $^{222}Rn$ in air. When nitrogen gas flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of $^{222}Rn$ decreased about 80% below 1 MeV and about 20~50% above 1 MeV. The use of nitrogen purging results in approximately tenfold increment of sensitivity.

  • PDF

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF