• Title/Summary/Keyword: Back-contact

Search Result 367, Processing Time 0.03 seconds

Bow Reduction in Thin Crystalline Silicon Solar Cell with Control of Rear Aluminum Layer Thickness (박형 결정질 실리콘 태양전지에서의 휨현상 감소를 위한 알루미늄층 두께 조절)

  • Baek, Tae-Hyeon;Hong, Ji-Hwa;Lim, Kee-Joe;Kang, Gi-Hwan;Kang, Min-Gu;Song, Hee-Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.194-198
    • /
    • 2012
  • Crystalline silicon solar cell remains the major player in the photovoltaic marketplace with 80% of the market, despite the development of various thin film technologies. Silicon's excellent efficiency, stability, material abundance and low toxicity have helped to maintain its position of dominance. However, the cost of silicon materials remains a major barrier to reducing the cost of silicon photovoltaics. Using the crystalline silicon wafer with thinner thickness is the promising way for cost and material reduction in the solar cell production. However, the thinner the silicon wafer is, the worse bow phenomenon is induced. The bow phenomenon is observed when two or more layers of materials with different temperature expansion coefficiencies are in contact, in this case silicon and aluminum. In this paper, the solar cells were fabricated with different thicknesses of Al layer in order to reduce the bow phenomenon. With less amount of paste applications, we observed that the bow could be reduced by up to 40% of the largest value with 120 micron thickness of the wafer even though the conversion efficiency decrease by 0.5% occurred. Since the bowed wafers lead to unacceptable yield losses during the module construction, the reduction of bow is indispensable on thin crystalline silicon solar cell. In this work, we have studied on the counterbalance between the bow and conversion efficiency and also suggest the formation of enough back surface field (BSF) with thinner Al layer application.

A Kinematic Analysis of Gait Patterns between the Normal Men and the Lower Limb Handicapped (정상인과 하지장애자의 보행형태에 대한 운동학적 분석)

  • Kim, Moo-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.163-180
    • /
    • 2003
  • This paper aims at collecting the guantitative data of kenematic variables by analysing the gait patterns of the normal adult men and the handicapped. The gait motions were taped with 4 video cameras, the cinematographic analyses were performed by the DLT technique of three dimensional image treatment. The following results were obtained in the analysis of the variables: 1. The ratio of stance time and swing time did not show any significant difference in the groups of the normal men and the handicapped when both foot of the former and the right feet of the latter were compared. The stride peeriod time of these two groups were 1.12 and 1.11 second, respectively. 2. In the handicapped group, the step width was wider, the step length and stride length were shorter, and especially, the step length of the right foot was shorter, 3. The small vertical displacement of left toes of the handicapped group showed that the heal contact and the left midstance are almost simultaneous. 4. The two groups have almost the same horizontal displacement of the center of gravity and the same vertical rate of extension. In view of the velocity of the center of gravity the normal adults showed the constant speed of movement. However, the handicapped adults were reduced from the right midstance to the right toe-off. 5. The handicapped showed prominently low angle on the left toe-off in the ankle joint angle, they also had the tendency to walk in the patterns of extended knee in the knee joint angle. Both the handicapped and the normal had the hyperextension on the toe-off in the hip joint angle. In the back and front angle of body, both showed the slightly back-sided walking positions. 6. Both groups had the abduction of both feet in foot placement angle, but the handicapped did not show serious abduction of left midstance.

A Study on the Electrochemical Deposition and p-Type Doping of ZnTe Films as a Back Contact Material for CdTe Photovoltaic Solar Cells (CdTe계 태양전지에 응용되는 ZnTe 박막의 전기화학적 제조 및 Cu 도핑 연구)

  • Kim, Dong-Hwan;Jeon, Yong-Seok;Kim, Gang-Jin
    • Korean Journal of Materials Research
    • /
    • v.7 no.10
    • /
    • pp.856-862
    • /
    • 1997
  • 박막형 CdTe/CdS 태양전지의 배면전극(back contacts)물질로서 Cu도핑된 ZnTe 박막(ZnTe:Cu)을 전착법(electroplating)으로 제조하는 연구를 수행하였다. Sulfate계의 전해질 수용액에서 CdTe 기판과 투명전극으로 코팅된 유리(In$_{2}$O$_{3}$: Sn, ITO)기판 위에 ZnTe 박막을 코팅하는 방법으로써 potentiostat와 기판(cathode), Pt counter electrode, Ag/AgCI 표준전극으로 구성된 장치를 사용하여 pH=2.5-4, T=70-8$0^{\circ}C$, 0.02M $Zn^{2+}$ 1x$10^{-4}$M TeO$_{2}$, 0.2M $K_{2}$SO$_{4}$조건에서 -0.800 Vs~-0.975 V 범위의 전압(V$_{a}$ )에 걸쳐 실험하였다. ITO박막을 기판으로 사용하여 cyclic voltammogram을 작성한 결과 약 -0.50 V 에서 Te환원 peak이 나타났다. Auger electron spectroscopy (AES)로 조성분석한 결과 표면에서 Zn signal이 강하게 나왔고 시편의 두께에 따라 Zn의 signal감소하는 반면 Cd signal은 증가하는 것이 확인되었다. SEM 사진으로부터 ZnTe의 표면이 작은 입자 (0.2$\mu\textrm{m}$ 이하)로 구성되어 있으며 낮은 V$_{a}$ 에서는 입자가 작아지면서 조직이 치밀해짐이 관찰되었다. Optical transmission방법에 의하여 ITO기판위에 입혀진 박막의 밴드갭은 2.5 eV으로 측정되었다. 수용액중의 Cu$_{2+}$와 triethanolamine(TEA)은 산성용액에서 착물형성이 이루어지지 않았으며 1,10-phenanthroline과는 pH=2에서도 착물이 형성되었다.

  • PDF

Pt/Al Reaction Mechanism in the FeRAM Device Integration (FeRAM 소자 제작 중에 발생하는 Pt/Al 반응 기구)

  • Cho Kyoung-Won;Hong Tae-Whan;Kweon Soon-Yong;Choi Si-Kyong
    • Korean Journal of Materials Research
    • /
    • v.14 no.10
    • /
    • pp.688-695
    • /
    • 2004
  • The capacitor contact barrier(CCB) layers have been introduced in the FeRAM integration to prevent the Pt/Al reaction during the back-end processes. Therefore, the interdiffusion and intermetallic formation in $Pt(1500{\AA})/Al(3000{\AA})$ film stacks were investigated over the annealing temperature range of $100\sim500^{\circ}C$. The interdiffusion in Pt/Al interface started at $300^{\circ}C$ and the stack was completlely intermixed after annealing over $400^{\circ}C$ in nitrogen ambient for 1 hour. Both XRD and SBM analyses revealed that the Pt/Al interdiffusion formed a single phase of $RtAl_2$ intermetallic compound. On the other hand, in the presence of TiN($1000{\AA}$) barrier layer at the Pt/Al interface, the intermetallic formation was completely suppressed even after the annealing at $500^{\circ}C$. These were in good agreement with the predicted effect of the TiN diffusion barrier layer. But the conventional TiN CCB layer could not perfectly block the Pt/Al reaction during the back-end processes of the FeRAM integration with the maximum annealing temperature of $420^{\circ}C$. The difference in the TiN barrier properties could be explained by the voids generated on the Pt electrode surface during the integration. The voids were acted as the starting point of the Pt/Al reaction in real FeRAM structure.

Effect of coagaulation on ceramic microfiltration membrane fouling (응집공정이 세라믹 정밀여과막 파울링에 미치는 영향)

  • Hwang, Young Jin;Lim, Jae Lim;Choi, Young Jong;Wang, Chang Gun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.459-469
    • /
    • 2009
  • It is well known that coagulation pretreatment can reduce foulants prior to membrane filtration. The purpose of this research was to investigate the effects of coagulation on fouling of ceramic microfiltration membrane($0.1 {\mu}m$) using pilot plant of $150m^3/day/train$ capacity. Train A membrane system has pretreatment process of ozonation and coagulation while train B has only coagulation. Two types of coagulation operation were investigated: back mixer(rapid mixing with or without slow mixing) which is a conventional mechanically stirred mixer and an inline static mixer. Ozone dose rate for train A was 1 mg/L and ozone contact time was 12 min. The coagulation dose(PACl 10% as $Al_2O_3$) rate was changed 20~40 mg/L according to experimental schedule. In this experimental conditions, the coagulation of back mixer type with rapid mixing(GT=72,000) and slow mixing(GT=45,000) was the best effective in reduction of ceramic membrane fouling regardless preozonation. Especially, the effect of inline static mixer was sensitive to change in water quality. Ozonation mainly affected irreversible fouling rather than reversible fouling in accordance with less adsorption of NOM on the membrane surface. Thus, the increase rate of the nomalized TMP(trans membrane pressure) at $25^{\circ}C$ for train A was relatively lower than that of train B under same coagulation process with same coagulant dosage. The best performance of ceramic membrane appeared in case of combined process with ozonation, therefore this integrated process is able to archive less coagulant dosing and secure a stability of ceramic membrane system.

Degradation of electrical characteristics in Bio-FET devices by O2 plasma surface treatment and improving by heat treatment (O2 플라즈마 표면처리에 의한 Bio-FET 소자의 특성 열화 및 후속 열처리에 의한 특성 개선)

  • Oh, Se-Man;Jung, Myung-Ho;Cho, Won-Ju
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.199-203
    • /
    • 2008
  • The effects of surface treatment by $O_2$ plasma on the Bio-FETs were investigated by using the pseudo-MOSFETs on the SOI substrates. After a surface treatment by $O_2$ plasma with different RF powers, the current-voltage and field effect mobility of pseudo-MOSFETs were measured by applying back gate bias. The subthreshold characteristics of pseudo-MOSFETs were significantly degraded with increase of RF power. Additionally, a forming gas anneal process in 2 % diluted $H_2/N_2$ ambient was developed to recover the plasma process induced surface damages. A considerable improvement of the subthreshold characteristics was achieved by the forming gas anneal. Therefore, it is concluded that the pseudo-MOSFETs are a powerful tool for monitoring the surface treatment of Bio-FETs and the forming gas anneal process is effective for improving the electrical characteristics of Bio-FETs.

Study of transfer film in the sliding of nanoscale CuO-filled and fiber-reinforced polyphenylene sulfide (PPS) composites (CuO nanoparticle 및 fiber 로 구성된 PPS 복합재료의 sliding 조건하의 transfer film 에관한 연구)

  • Cho, Min-Haeng;Bahadur, Shyam;Park, Hye-Young;Kim, Yoon-Jun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.967-972
    • /
    • 2004
  • The role of transfer films formed during sliding of polymer composites against steel counterfaces was studied in terms of the tribological behaviors of composites. Four kinds of composites were included in this study: (1) unfilled PPS, (2) PPS+2%CuO, (3) PPS+2%CuO+5% carbon fiber (CF), and (4) PPS+2%CuO+15%Kevlar. The filler material CuO was in nanoscale particulate form and the reinforcing material was in the form of short fibers. The composites were prepared by compression molding at $310^{\circ}C$ and sliding tests were run in the pin-on-disk sliding configuration. The counterface was made of tool steel hardened to 55-60 HRC and finished to a surface roughness of 0.09-0.10 ${\mu}m$ Ra. Wear tests were run for 6 hrs at the sliding speed of 1 m/s and contact pressure of 0.65 MPa. Transfer films formed on the counterfaces during sliding were investigated using AFM and SEM. The results showed that as the transfer film became smooth and uniform, wear rate decreased. PPS+2%CuO+15%Kevlar composite showed the lowest steady state wear rate in this study and its transfer film showed the smoothest and the most uniform characteristics. The examination of worn surfaces of PPS+2%CuO composite using X-ray area scanning (dot mapping) showed back-transfer of steel counterface material to the polymer pin surface. This behavior is believed to strengthen the polymer pin surface during sliding thereby contributing to the decrease in wear rate.

  • PDF

Investigation of the body distribution of load pressure and virtual wear design of short pants harnesses in flying condition (플라잉 상태에서 바지형태의 하네스에 대한 하중압력 분포 측정 및 가상착의 적용)

  • Kwon, MiYeon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.3
    • /
    • pp.11-21
    • /
    • 2021
  • Virtual reality is currently mainly used in games, but is starting to be applied as a variety of media fields, such as broadcasting and film. Virtual reality provides more fun than reality, and can provide new experiences in areas that cannot be experienced in reality due to the constraints of time, space, and environment. In particular, as the social non-contact arena has increased due to COVID-19, it is being applied to education, health, and medical industries. The contents are further expanding into design and military fields. Therefore, the purpose of this study was to observe the change in distribution of load and pressure felt by the body in the flying state while wearing a short pants harness, which are mainly used in the game and entertainment industry. In the experiment, the average pressure in the flying state was measured by attaching a pressure sensor to the back and front of a human mannequin. As a result, it was confirmed that the load concentrated on the waist in the flying state was 44 N, with a pressure of 1353 kPa. The pressure distribution was concentrated in front of the center of gravity, and was measured was at 98% by the pressure sensors, with an average pressure value of approximately 15 kPa, and a pressure value of approximately 12 kPa at the back, which was measured at 67% by the pressure sensor. The results of the load and pressure distribution measurement are presented as fundamental data to improve the wearability and comfort of harnesses in the future, and are compared to actual measured pressure values by analyzing the clothing pressure in flight through virtual wear of harnesses through the CLO 3D program.

A study on dermatologic diseases of workers exposed to cutting oil (절삭유 취급 근로자의 피부질환에 관한 연구)

  • Chun, Byung-Chul;Kim, Hee-Ok;Kim, Soon-Duck;Oh, Chil-Hwan;Yum, Yong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.785-799
    • /
    • 1996
  • We investigated the 1,004 workers who worked in a automobile factory to study the epidemiologic characterists of dermatoses due to cutting oils. Among the workers, 667(66.4%) answered the questionaire. They are belong to 5 departments of the factory-the Engine-Work(258 workers), Gasoline engine Assembly(210), Diesel engine Assembly(96), Power train Work(86), Power train Assembly(17). We measured the oil mist concentration in air of the departments and examined the workers who had dermatologic symptoms. The results were follows; 1) Oil mist concentration ; Of all measured points(52),9 points(17.2%) exeeded $5mg/m^3$- the time-weighed PEL-and one department had a upper confidence limit(95%) higher than $5mg/m^3$. 2) Dermatologists examined 213 workers. 172 of them complained any skin symptoms at that time - itching(32.5%), papule(21.6%), scale(15.7%), vesicle(12.5%) in order. The abnormal skin site found by dermatologist were palm(29.3%), finger & nail(24.6%), forearm(16.2%), back of hand(8.4%) in order. 3) As the result of physical examination, we found that 160 workers had skin diseases. Contact dermatitis was the most common; 69 workers had contact dermatitis alone(43.1%), 11 had contact dermatitis with acne(6.9%), 10 had contact dermatitis with folliculitis(6.3%), 1 had contact dermatitis with acne & folliculitis, and 1 had contact dermatitis with abnormal pigmentation. Others were folliculitis(9 workers, 5.6%), acne(8, 5.0%), folliculitis & acne (2, 1.2%), keratosis(1, 0.6%), abnormal pigmentation (1, 0.6%), and non-specific hand eczema (47, 29.3%). 4) The prevalence of any skin diseases was 34.0 pet 100 in cutting oil users, and 13.3 per 100 in non- users. Especially, the prevalence of contact dermatitis was 23.0 per 100 in cutting oil users and 23.0 per 100 in non-users. 5) We tried patch test(standard serise, oil serise, organic solvents) on 49 patients to differentiate allergic contact dermatitis from irritant contact dermatitis and found 20 were positive. 6) In a multivariate analysis(independant=age, tenure, kinds of cutting oil), the risk of skin diseases was higher in the water-based cutting oil user and both oil user than non-user or neat oil user(odds ratio were 2.16 and 2.78, respectively). And the risk of contact dermatitis was much higher at the same groups(odds ratio were 5.16 and 6.82, respectively).

  • PDF

A Field Test Assessment on the Extremity Doses of Highly-Exposed Radiation Workers During Maintenance Periods at Nuclear Power Plants in Korea (원전 계획예방정비기간 고피폭 접촉작업에서 방사선작업종사자의 말단선량 평가 현장시험)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • Maintenance on the water chamber of steam generator, the change of pressurizer heater, the removal of pressure tube feeder, and so on during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, field tests on extremity dose assessment of radiation workers for contact works with high radiation exposure were conducted during the maintenance periods in Korean pressurized water reactors (PWRs) and pressurized heavy water reactors (PHWRs). In this field test, radiation workers were required to wear additional TLDs on the back and wrist, and an extremity dosimeter on fingers including a main TLD on the chest, while performing maintenance. As a result, it was found that the equivalent dose for fingers was distributed in the fixed range of deep dose and the equivalent dose for wrists.