• 제목/요약/키워드: Back shielding

검색결과 33건 처리시간 0.028초

Development of Heat Absorbing and High Electromagnetic Shielding Pre-Painted Steel Sheet

  • Hosokawa, Tomoaki;Ueda, Kohei;Yuasa, Kensei;Nakazawa, Makoto
    • Corrosion Science and Technology
    • /
    • 제9권4호
    • /
    • pp.153-158
    • /
    • 2010
  • Electrical appliances such as audiovisual equipment and personal computers have recently had heat and electromagnetic problems. In order to solve those problems, 'High heat absorbing pre-painted steel sheet (hereinafter referred to as PSS)', 'High electromagnetic shielding PSS' and 'High heat absorbing and high electromagnetic shielding PSS' have been developed. In this paper, the heat characteristics and electromagnetic shielding properties of PSS are investigated by methods that use enclosures and their mechanisms are discussed. It was found that 'High heat absorbing PSS' and 'High heat absorbing and high electromagnetic shielding PSS'could reduce the heat problem. The mechanism of the heat characteristics was presumed for the high heat absorptivity of the back coating inside the enclosure. And it was also found that 'High electromagnetic shielding PSS' and 'High heat absorbing and high electromagnetic shielding PSS' could shield electromagnetic waves well. The mechanism of the electromagnetic shielding properties was considered for the low transfer impedance of the back coating inside the enclosure. 'High heat absorbing PSS' and 'High electromagnetic shielding PSS' have been adopted as materials for electrical appliances and 'High electromagnetic shielding and high heat absorbing PSS' have been tested for that purpose.

국내에서 발생한 낙뢰고장 분석을 통한 직격뢰 및 역섬락 고찰 (Consideration on shielding failure and back flashover through lightning fault analysis within the country)

  • 최한열;민병욱;박순규;이봉희;구성완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.280_281
    • /
    • 2009
  • The past 3 years study on the lightning faults data shows that the main reason is shielding failure rather than back flashover. Accordingly, we need to thoroughly consider about shielding failure angle of tower. Also, transmission line damage caused by shielding can be minimized if we avoid the steep slope area as a transmission line route.

  • PDF

임산부 흉부촬영 시 복부차폐의 적정성 평가 (Adequacy Assessment to Abdomen Shield of Pregnant X-ray Chest PA)

  • 김기진;김가중
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.207-212
    • /
    • 2015
  • When performing Chest x-ray examination to pregnant woman, normally we shield back side of abdomen. In this situation, scattered rays made by equipment and surrounding structure can enter front side of abdomen. Therefore, in this study, we evaluate suitability of abdomen shield especially to pregnant woman. In case of One shielding material placed back of abdomen, the measured value is $0.676{\pm}0.19uSv/hr$. Two shielding material is $0.764{\pm}0.04uSv/hr$. Three is $0.685{\pm}0.16uSv/hr$. The exposure dose inferred in this study does not excess annual effective dose limit. But It is not mean absolute safety. So we have to minimize occurrence of stochastic effect of radiosensitivity by shielding front side of abdomen of pregnant woman in clinic.

Al 5J32 합금의 레이저 용접에서 레이저출력 모듈레이션을 이용한 이면 험핑 비드의 안정화 (Prevention of Back Side Humping in Laser Welding of Al 5J32 Alloy by Using Laser Power Modulation)

  • 안도창;김철희;김재도
    • Journal of Welding and Joining
    • /
    • 제29권4호
    • /
    • pp.80-84
    • /
    • 2011
  • In the 5xxx series Al-Mg alloy, magnesium addition can increase the strength of aluminum alloy by solid solution strengthening but it has a relatively low melting and boiling temperature. During full -penetration laser welding of the Al-Mg alloys, its low boiling point and high vapor pressure brings about the spiky humping bead on the bottom side. Under back-side shielding, the spiking of back bead can be reduced but it restraints the process flexibility. In this study, a square pulse waveform modulation was employed to stabilize keyhole and back bead surface without back-side shielding. By using an experimental design, the bead shapes were evaluated for various process parameters such as the focal position, welding velocity and waveform parameters and the smooth back bead shape could be achieved.

345[KV] 송전선로의 뇌방호 실패의 예측과 그 대책에 관한 연구 (A study on lighting performance of 345[KV] model line)

  • 이봉용
    • 전기의세계
    • /
    • 제29권1호
    • /
    • pp.65-72
    • /
    • 1980
  • Arstrong-Whitehead theory on effective shielding and shielding failure is extended so that it is applicable to vertical line configuration the existing approaches on back-flash rate calculation are summerized and compared in particular on Model Line, and the usefulness of the whitehead approach is suggested.

  • PDF

티타늄 용접공정에서 온도특성에 따른 실딩방법에 관한 연구 (A study on the titanium welding process according to the temperature characteristics of shielding methods)

  • 정한식;정효민;이대철;이병용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권1호
    • /
    • pp.29-34
    • /
    • 2013
  • 용접과정 중에 용접부가 공기에 노출되면 용접성능을 약화시킨다. 불활성가스 텅스텐 아크용접(GTAW)법을 사용하여 티타늄 용접을 하는 경우 용접부가 자주/적색, 청색, 노란색, 회색, 흰색 등의 빛깔을 보이면 이는 용접 시 공기 중의 산소와 질소에 오염된 것을 의미한다. 따라서 용접부를 대기로부터 보호하기 위한 방법으로 실딩 가스를 사용한다. 이것은 대기에 의한 오염을 방지할 뿐만 아니라 용착부와 열영향부도 상온까지 냉각될 때까지 대기로부터 차단시킨다. 본 연구에서는 Trailing Shielding Jig 의 모양과 형태 그리고 토치보호($13{\sim}20{\ell}/min$), 후방보호($22{\sim}30{\ell}/min$), 이면보호($25{\sim}30{\ell}/min$)등 건전한 용접부에 적합한 실딩 가스에 대한 결과를 도출하였다.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제40권6호
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

질소 이면보호가스 적용성에 관한 연구 (Effect of $N_2$ back shielding gas on the property change of GTA weldment)

  • 백광기;안병식
    • Journal of Welding and Joining
    • /
    • 제5권4호
    • /
    • pp.12-21
    • /
    • 1987
  • To investigate the suitability of nitrogen gas as an internal purging gas, various properties of GTA welded joints of duplex, 316L stainless steel, Cu-Ni alloy pipe using nitrogen purging gas were evaluated with reference to onew purged with argon gas. Mechanical properties evaluated by the tensile, bending test, and hardness value of welded joints with nitrogen gas purging did not show any difference those with argon gas. General and local corrosion rates of each welded joint prepared by nitrogen gas purging also showed no difference with those prepared by argon gas. Based on the present test results it is confirmed that nitrogen is a suitable purging gas for GTA welding of stainless steels and nonferrous piping systems, which can be used at lower cost instead of argon.

  • PDF

방사선(放射線) 차폐물질(遮蔽物質)에 대(對)한 산란선발생(散亂線發生)에 관한 연구(硏究) (A Study on the Scattered-rays from the Radiation Shielding Materials)

  • 김창균;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제3권1호
    • /
    • pp.67-72
    • /
    • 1980
  • To shield the radiation, we can make use of various materials, but the scattered rays can be caused by the shielding materials. The degree of the scattered rays production is influenced by the nature of the shielding materials and the energy of the radiation, therefore to choose the proper shielding material is the most important matter in radiation protection. Authors made an experimental study on the scattered rays generated from the shielding materials, and obtained the results as follows: 1. In the ranking of the scattered rays production: Cement bricks, black colored fire bricks, and red colored fire bricks were marked the first the second, and the third ranking respectly, and the last order was lead plates. 2. In the relative ranking of the scattered rays production by energy increase: Lead plates were marked the first order, the next and third order were red colored fire bricks and black colored fire bricks respectly, and cement bricks were marked the last order. 3. The scattered ray ratio of lateral-back point per lateral point were generally decreased by energy increment. The diminishing orders were that lead plates were the first order, and the next and the third order were red colored fire bricks and black colored fire bricks respectly, cement bricks were marked the last order.

  • PDF

영상표시단말장치의 작업공간 배열에 따른 전자파 폭로 정도 (The Level of Exposure to Electromagnetic Fields Strength from VDT According to the Arrangement of Working Space VDT)

  • 한상일;이세훈
    • 한국산업보건학회지
    • /
    • 제8권1호
    • /
    • pp.146-154
    • /
    • 1998
  • This study was designed to investigate the workers' exposure level to electromagnetic field(EMF) in accordance with the VDT arrangement in the work place and distance from VDT. Author compared the exposure strength of EMF in line group(workers exposed to EMF from both front and back side) and in shielding group(workers exposed to EMF exclusively from front side). The levels of EMF at 30cm and 50cm from front side and at 30cm from back side of VDT were also measured. The result were as follows: 1. Mean distance between a monitor and a worker in shielding group ($47.7{\pm}8.7cm$) significantly longer than that in line group($44.3{\pm}7.2cm$). Strength of EMF in shielding group [$1.3{\pm}0.7V/m$ (electric field) and $18.2{\pm}11.5mA/m$ (magnetic field) were lower than in line group [$1.4{\pm}0.6V/m$ and $26.6{\pm}11.6mA/m$, respectively] at the workers' position. 2. The strength of EMF was decreased with the distance from VDT. The strength at 70cm from VDT was nearly the same as the background strength in the ordinary office rooms. 3. Working distance from 9 inch monitor was significantly shorter than that from 14 inch and wider sized monitors. 4. The strength of EMF in extremely low frequency spectrum of color monitors was higher then that of black and white monitor. 5. Metal coated filters significantly decreased the electric field strength of EMF when earth line was connected. Metallic shield was effectively decreased the EMF strength from VDT, but wooden shield was not. From the above results, line type arrangement of VDT in the work place using metallic shield at the back side of VDT, and metal coated filter to monitor with application of earth line were recommended. It is also recommended to maintain workers position to be 60cm or more distance from monitor and 140cm or more between VDTs for minimizing workers' exposure to EMF.

  • PDF