Study on the material properties and heating efficiency according to the internal surface coating of the brazed plate heat exchanger (BPHE) (접합 판형 열교환기(BPHE)의 내부 코팅에 따른 소재 특성 및 성능 평가에 관한 연구)

  • Jung, Hangchul;Yang, Hyunseok;Kim, Hyunjong;Park, Jongpo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.6
    • /
    • pp.237-243
    • /
    • 2020
  • In this study, a silane-based coating was applied to improve corrosion resistance and thermal efficiency performance of a brazed plate heat exchanger (BPHE) composed of stainless plate and copper (Cu) brazing. Although the selected coating material was applied to the BPHE by evaluating the corrosion and contact angle according to the coating material, the result of the heat transfer performance evaluation showed that the thermal efficiency was lower than that of the uncoated BPHE. It was analyzed that the adhesion of the coating agent to the flow path inside the BPHE and the residual coating agent on the surface acted as heat resistance, preventing heat transfer. This is due to the structural characteristics of the BPHE in which a fine flow path exists inside, and it is believed that manufacturing after coating the surface of the flow path in advance in the manufacturing process of the BPHE can improve heat transfer performance.

Experimental measurements of R-22 two-phase friction factor in plate heat exchangers (판형열교환기에서 R-22 냉매의 이상 압력 손실계수 평가)

  • Yoo, Sang-Roon;Jeong, Ji-Rwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2273-2278
    • /
    • 2007
  • Brazed Plate Heat Exchanger (BPHE) is a type of compact plate heat exchanger with parallel corrugated plates which are brazed together in series. Each plate hascorrugation called herringbone pattern. Inside a BPHE, hot fluid and cold fluid alternate its flow direction to establish counter current flow configuration. Two-phase flow heat transfer and pressure drop of R-22 in BPHE were experimentally measured in this study. In the present experiments, single-phase region and two-phase region coexist in a BPHE. Therefore, the inside of a BPHE have to be divided into single phase region and two phase region and analyzed accordingly. The results from the single phase flow analysis are then extended to the two phase flow analysis to correlate the condensation and evaporation heat transfer and pressure drop for the refrigerant R-22 in the BPHEs. Previous models for two- phase friction factor have been compared with the present experimental results.

  • PDF