동맥압 형태변화에 따른 혈압 보정에 관한 연구 (A Study on the Compensation of Blood Pressure Caused by the Change of Arterial Pressure Shape)

  • 임성수;박광리;이경중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.177-178
    • /
    • 1998
  • This paper is a study on compensation for error in estimation of mean pressure according to the change of arterial pressure shape. Because arterial pressure shape affects the mean pressure and blood volume which are important factors for measurement of blood pressure(BP), change of arterial pressure shape cause BP measurement error. In order to solve this problem, we add the compensation function C($\alpha$), depending on arterial pressure shape, to mathematical oscillometric model. Consequently, we could accurately estimate the blood pressure by correcting of the error using compensation function.

  • PDF

Time-Delay and Amplitude Modified BP Imaging Algorithm of Multiple Targets for UWB Through-the-Wall Radar Imaging

  • Zhang, Huamei;Li, Dongdong;Zhao, Jinlong;Wang, Haitao
    • Journal of Information Processing Systems
    • /
    • 제13권4호
    • /
    • pp.677-688
    • /
    • 2017
  • In order to solve the undetected probability of multiple targets in ultra-wideband (UWB) through-the-wall radar imaging (TWRI), a time-delay and amplitude modified back projection (BP) algorithm is proposed. The refraction point is found by Fermat's principle in the presence of a wall, and the time-delay is correctly compensated. On this basis, transmission loss of the electromagnetic wave, the absorption loss of the refraction wave, and the diffusion loss of the spherical wave are analyzed in detail. Amplitude compensation is deduced and tested on a model with a single-layer wall. The simulating results by finite difference time domain (FDTD) show that it is effective in increasing the scattering intensity of the targets behind the wall. Compensation for the diffusion loss in the spherical wave also plays a main role. Additionally, the two-layer wall model is simulated. Then, the calculating time and the imaging quality are compared between a single-layer wall model and a two-layer wall model. The results illustrate the performance of the time-delay and amplitude-modified BP algorithm with multiple targets and multiple-layer walls of UWB TWRI.

U-Healthcare시스템을 위한 PPG의 피부표면의 온도변화보상 (Compensation of Skin Surface Temperature Variation on the PPG for the U-Healthcare System)

  • 염호준
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.319-324
    • /
    • 2011
  • 본 논문에서는 혈압과 광용적맥파, 국부피부온도변화에 따른 심혈관 파라메터의 통계적 변화와 관계에 대해 연구하였다. 국부피부온도변화는 Finometer의 혈압, 광용적맥파 그리고 총말초저항에 영향을 주었고 오실로메트릭 혈압, 심박수, 심박출량에는 영향을 주지 않는 결과를 얻었다. 그러므로 온도변화가 있는 환경에서 에러를 줄이기 위해 심혈관계의 상태를 광용적맥파로 평가하기위해서는 온도를 제어하거나 보상해 주어야 한다.

다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상 (Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals)

  • 정운모;심명헌;정상오;김민용;윤찬솔;정인철;윤형로
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

Complexity Analysis of Internet Video Coding (IVC) Decoding

  • Park, Sang-hyo;Dong, Tianyu;Jang, Euee S.
    • Journal of Multimedia Information System
    • /
    • 제4권4호
    • /
    • pp.179-188
    • /
    • 2017
  • The Internet Video Coding (IVC) standard is due to be published by Moving Picture Experts Group (MPEG) for various Internet applications such as internet broadcast streaming. IVC aims at three things fundamentally: 1) forming IVC patents under a free of charge license, 2) reaching comparable compression performance to AVC/H.264 constrained Baseline Profile (cBP), and 3) maintaining computational complexity for feasible implementation of real-time encoding and decoding. MPEG experts have worked diligently on the intellectual property rights issues for IVC, and they reported that IVC already achieved the second goal (compression performance) and even showed comparable performance to even AVC/H.264 High Profile (HP). For the complexity issue, however, there has not been thorough analysis on IVC decoder. In this paper, we analyze the IVC decoder in view of the time complexity by evaluating running time. Through the experimental results, IVC is 3.6 times and 3.1 times more complex than AVC/H.264 cBP under constrained set (CS) 1 and CS2, respectively. Compared to AVC/H.264 HP, IVC is 2.8 times and 2.9 times slower in decoding time under CS1 and CS2, respectively. The most critical tool to be improved for lightweight IVC decoder is motion compensation process containing a resolution-adaptive interpolation filtering process.

광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정 (Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor)

  • 고재일;정인철;이동희;박신우;황성오;박소미;김기연;주현실;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.