• Title/Summary/Keyword: BOD(Biochemical Oxygen)

Search Result 187, Processing Time 0.027 seconds

A Study on the Control of Stream Water Pollution Caused by Construction of the Industrial Complex in Agricultural Area (Centering around Area of chung chong Nam Do) (농공단지 조성에 따른 하천 수질관리 대책에 관한 연구 (충청남도 지역을 중심으로))

  • 양천회
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.1
    • /
    • pp.155-160
    • /
    • 1994
  • A study of stream pollution caused by construction of the Industrial Complex in Agricultural Area of Chung Chong Nam Do were descrived here. The five main results of this studies are summerized. First, since 1988, among the companies moved in the industrial complex area, the number of electric and electronic companies have increased compared with food companies requiring much BOD. This Is very desirable to reduce the water pollution. Second, the average Biochemical Oxygen Demand(BOD) of Masan stream was the highest and it was decreased in the order of Yudug, Jo and Jungan stream. Third, although the concentration of heavy metals such as Cd and C $r^{6+}$ are not off the limit and the amount of it is small, it is desirable to introduce a chemical process to remove these metals. Fourth, since the wastewater from industrial complex area is the major factor in stream pollution, the laws associated with environmental protection should be enforced even then if the Industrial complex area with food and chemical companies produce wastewater less than 500ton/day. Fifth, it is required to improve a facilities which separete living wastewater from inderstrial wastewater In Kaya-gok and Nojang industrial complex areas.

  • PDF

Prediction of Chlorophyll-a Changes due to Weir Constructions in the Nakdong River Using EFDC-WASP Modelling

  • Seo, Dong-Il;Kim, Min-Ae;Ahn, Jong-Ho
    • Environmental Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.95-102
    • /
    • 2012
  • To evaluate the effect of the 4 major rivers restoration project in the Nakdong River to water quality of the river, the Environmental Fluid Dynamics Code (EFDC) and Water Quality Analysis Simulation Program (WASP), are applied in series. Results showed overall decrease in biochemical oxygen demand ($BOD_5$) concentrations and increase in chlorophyll-a concentrations, while total nitrogen and total phosphorous concentrations did not show significant changes, relatively. Decrease in $BOD_5$ concentrations seems to be influenced by an increased hydraulic residence time, which may allow more time for the degradation of organic material. Changes in Chlorophyll-a (Chl-a) concentration, due to the project were more significant for the upper stream areas that show relatively low Chl-a concentration ranges (less than 20 g/L). After the introduction of the Geumho River in the middle part of the Nakdong River, rapid growth of phytoplankton was observed. However, in this middle part of the Nakdong River, the ratio of Chl-a concentration change are less significant, compared to the upper stream areas, due to the project. In the lower stream area, Chl-a concentration decreased after the project. This seems to be resulted from the decreased light availability, due to increased depth, while the nutrient concentrations have been high enough to support phytoplankton growth.

Ship Sewage Treatment Using Fixed Media Method (고정식 메디아법을 이용한 선박의 오폐수 처리)

  • Han, Sang-Hwa;Lee, Dea-Ho;Nyung, Bu-Nyung;Bae, Sang-Bum;Yoon, Jong-Mun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The purpose of this study is to develop Sewage Treatment Plant that treat sewage which occurred in ship using fixed media method and to consider applicable to the Pilot Scale device of the STP regulations in MLTM(Ministry of Land, Transport and Maritime Affairs) and MEPC(Marine Environment Protection Committee). In test results, pH geometric mean was 7.68, $BOD_5$(Biochemical Oxygen Demand) geometric mean was 7.28 mg/l, $COD_{cr}$(Chemical Oxygen Demand) geometric mean was 48.39 mg/l, TSS(Total Suspended Solid) geometric mean was 18.00/l, Residual chlorine geometric mean was 0.19 mg/l, and E. coli geometric mean was 1CFU/100 ml. In addition, about 97.4% of $BOD_5$ was reduced, the $COD_{cr}$ reduction averaged 96.4%and the TSS reduction averaged 97.6%. STP have been determined by the MLTM and MEPC regulation of the marine pollution prevention equipment for performance testing product.

Simple Material Budget Modeling for a River-Type Reservoir (하천형 저수지의 단순 물질수지 모델링)

  • Yoon, Seong-Kyu;Kong, Dong-Soo;Bae, Wookeun
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.420-431
    • /
    • 2010
  • Simple material budget models were developed to predict the dry season water quality for a river-type reservoir in Paldang, Republic of Korea. Of specific interest were the total phosphorus (TP), chlorophyll ${\alpha}$ (Chl. ${\alpha}$), 5-day biochemical oxygen demand (BOD), and chemical oxygen demand (COD). The models fit quite well with field data collected for 20 years and have enabled the identification of the origins of organic materials in the reservoir. The critical hydraulic load that determines the usability of phosphorus for algal production appeared to be about $1.5m\;d^{-1}$. When a hydraulic load was smaller than the critical value, the concentrations of $Chl.{\alpha}$, COD, and BOD in the reservoir water became sensitive to internal algal reactions such as growth, degradation, and settling. In spite of the recent intensive efforts for organic pollutant removal from major point sources by central and local governments, the water quality in the reservoir had not been improved. Instead, the concentration of COD increased. The model analysis indicated that this finding could be attributed to the continuing increase of the algal production in the reservoir and the allochthonous load from non-point sources. In particular, the concentrations of COD and BOD of algal origin during 2000~2007, each of which is comprised of approximately one half of the total, were approximately 2.5 times higher than those observed during 1988~1994 and approximately 1.3 times higher than those between 1995~1999. The results of this study suggested that it is necessary to reduce the algal bloom so as to improve the water quality of the reservoir.

Status of Water Quality and Future Plans in the Philippines (필리핀의 수질현황 및 미래 관리계획)

  • Gorme, Joan B.;Maniquiz, Marla C.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.89-103
    • /
    • 2009
  • The Philippines is abundant with rich natural resources such as water. Because of rapid urbanization in the country, most of the water bodies are polluted as a result of domestic, agricultural and industrial activities. The Environmental Management Bureau (EMB) is the main government arm responsible for monitoring and inspection of affected water bodies. Only water bodies with at least four sampling events during dry and wet seasons were included in the assessment of water bodies that passed the DAO 90-34 water quality criteria. Water bodies were monitored for dissolved oxygen (DO), biochemical oxygen demand (BOD), total suspended solids (TSS), and total dissolved solids (TDS), heavy metals, fecal coliform contamination and nitrates. High pollutant concentrations from domestic, agricultural, industrial and nonpoint sources were observed from monitoring events due to inadequate sewage services and treatment facilities in the country. The objective of this paper was to present and evaluate the quality of the water bodies in the Philippines.

  • PDF

A Study on Performance Evaluation for the Bio-retention Non-point Source Pollution Treatment System (생물 저류 방법 적용을 통한 비점오염원 처리시설의 성능평가에 관한 연구)

  • Lee, Jang-Soo;Park, Yeon-Soo;Cho, Wook-Sang
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.295-299
    • /
    • 2013
  • This study was purposed and performed to evaluate removal efficiency of non-point source pollution in the process and system based on bio-retention design criteria regulated by EPA. Basic Column Reactors (BCR) were prepared for optimal determinations of inflow rate of first rainfall runoff and composition and ratio of soil layers. Removal efficiencies of non-point source pollution from synthetic runoff and real first rainfall runoff, directly sampled from motor way and parking lot, were analyzed, respectively. Removal efficiency of SS, BOD, COD, T-N, and T-P were all shown to be more than 80%.

A Study on Application and Verification of Heavy Water Treatment Effects Using Plant Cultivation (Vegetation) on Floating Island (식생섬에 의한 중수처리 효과 검증과 적용에 관한 연구)

  • Kwon, Dong Min;Kwon, Soon Hyo;Koo, Bon Hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This this study was conducted with the aim of doing experiment on the effect of water purification by using an artificially built plant island, which is one of the eco-techniques, and aquatic plants as a plan for the reuse of water for obtaining water resources, thereby analyzing the removed quantity, and applying the experimental results to the reuse of water. As a result of doing experiments, this study obtained a good measured value of BOD (biochemical oxygen demand) 4.7mg/L, and COD (chemical oxygen demand) 7.2mg/L below the heavy water standard of BOD 10mg/L and COD 20mg/L, respectively. The chromaticity showed 89.2% removal efficiency, but final treated wastewater was found to show chromaticity 58 degrees exceeding chromaticity 20 degrees which are the water quality standard of the reuse of water. The results revealed that T-N produced 27% removal efficiency on an average while T-P produced 38% removal efficiency on an average, showing that the removal effect of N & P wasn't big. According to the currently enforced "Water Quality Standard of Heavy Water by Use", the use of water for sprinkling and landscaping was found to be available. Accordingly, this study suggested a nature-friendly, economically-efficient, and eco-technological water treatment technique which will make it possible to overcome the limit of the existing physio-chemical water treatment technology, reduce the costs for maintenance and facilities, and also reduce the limit of space restraint for installation of facilities.

A Study on Removal Efficiency and Applicability of Natural Type Road Non-point Pollutant Reduction Facilities (자연형 도로 비점오염저감시설의 저감효율 및 적용성 연구)

  • Lee, Sang Hyuk;Cho, Hye Jin;Kim, Lee Hyung
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2014
  • PURPOSES : The purpose of this study is to assess removal efficiency of non-point pollutants and applicability for non-point pollutant reduction facilities by conducting the demonstration project operation. METHODS : In order to analyze removal efficiency of non-point pollutants for facilities such as a grassed swale, a small constructed wetland, a free water surface wetland, a horizontal sub-surface flow wetland, and a sand filtration, the field data including specifications of facilities, rainfall, inflow and runoff rainfall effluent etc. was acquired after occurring rainfall events, and the acquired data was analyzed for removal efficiency rate to assess road non-point pollutants facilities using event mean concentration (EMC) and summation of load (SOL) methods. RESULTS : The results of analyzing rainfall effluent, non-point pollutant sources showed that total suspended solid (TSS), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total nitrogen (TN), total phosphorus (TP), chrome (Cr), zinc (Zn), and lead (Pb) can be removed through non-point pollutant reduction facilities by 60.3% ~ 100%. Especially removal efficiency of TSS, COD and BOD is relatively higher than removal efficiency of other non-point pollutant sources in all kind of non-point pollutant facilities. CONCLUSIONS : Based on the result of this study, even though natural type of non-point pollutant reduction facilities for roads occupy small areas comparing with drainage basin areas, most of non-point pollutant sources would be removed through the facilities.

Estimation of the Effect of Water Quality Management Policy in Paldang Lake (팔당호 수질관리 정책의 효과 분석)

  • Choi, Jung-Hyun;Ha, Joo-Hyun;Park, Seok-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1225-1230
    • /
    • 2008
  • A new approach based on the Seasonal Mann-Kendall Trend Analysis, was presented in this paper, in order to estimate effect of water quality management policy in Kyoungan Stream which is one of major tributaries into the Lake Paldang. The estimation was undertaken by comparing water quality trend slopes before and after implementation of the policy. The monthly water quality data of Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Nitrogen (TN) and Total Phosphorus (TP) measured from 1992 to 2005, were analyzed to determine the Kendall slopes before and after the Han River special policy implemented at 1998. The results indicated that the 1998 special policy would be effective in water quality improvement not at upstream but at downstream. This result agrees well with the previous water quality studies at Kyoungan stream. It was suggested that the presented approach could be an useful tool to estimate effect of a water quality management policy.

The method for total organic carbon analysis employing TiO2 photocatalyst (이산화티타늄 광촉매를 이용한 총유기탄소 분석방법)

  • Park, Buem Keun;Kim, Sung Mi;Lee, Young-Jin;Paik, Jong-Hoo;Shin, Jeong Hee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.320-325
    • /
    • 2021
  • Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) methods are conventional analytical methods to analyze water quality. Both of these methods are technically indirect measurement methods, require complicated preconditions, and are time-consuming. On the other hand, the total organic carbon (TOC) method is a direct and fast measurement method which is more intuitive and accurate than the BOD and COD methods. However, general TOC analysis methods involve complicated processes and high power consumption owing to the process of phase transition from liquid to gas by a high-temperature heater. Furthermore, periodic consumables are also required for the removal of inorganic carbon (IC). Titanium dioxide (TiO2) is one of the most suitable photocatalysts for simple processes. Its usage involves low power consumption because it only reacts with the organic carbon (OC) without the requirement of any other reagents and extra processes. We investigated a TiO2 photocatalyst-based TOC analysis for simple and affordable products. TiO2-coated fiber substrate maintained under carbon included water was exposed to ultraviolet (UV) radiation of wavelength 365 nm. This method is suitable for the real-time monitoring of water pollution because of its fast reaction time. Its linear property is also sufficient to match the real value.