• Title/Summary/Keyword: BH Curve

Search Result 13, Processing Time 0.033 seconds

Core Loss Analysis of IPM Motor Considering Magnetic Saturation and Manufacturing of Electrical Steel (전기강판의 가공 및 포화를 고려한 IPM 모터의 철손 해석)

  • Ha, Kyung-Ho;Kim, Gi-Hyun;Kim, Jae-Kwan;Lee, Sun-Kwon;Na, Min-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.887.1_888.1
    • /
    • 2009
  • This paper proposes a core loss analysis method to obtain high accuracy prediction by using Multi-curve representing magnetic properties of a electrical steel in Finite Element Analysis (FEA). Generally, the magnetic prosperities of the electrical steel are measured by Epstein Method based on the international standards that are not good sufficient to predict motor performances. The method only aims to grade products in steel companies The magnetic properties of actual stator core is highly different to those given by steel companies due to the fact that stacking effect, shearing stress, nature anisotropy of electrical steels are not taken into account. In this paper, the magnetic properties are variously measured by three measuring devices, and then the several BH curves and BW curves obtained are used to analyze the core loss of a IPM. The BH curve in the high magnetic field are extrapolated using the mathematical formulation with the maximum saturation magnetic polarization measured

  • PDF

Black Hispanic and Black Non-Hispanic Breast Cancer Survival Data Analysis with Half-normal Model Application

  • Khan, Hafiz Mohammad Rafiqullah;Saxena, Anshul;Vera, Veronica;Abdool-Ghany, Faheema;Gabbidon, Kemesha;Perea, Nancy;Stewart, Tiffanie Shauna-Jeanne;Ramamoorthy, Venkataraghavan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9453-9458
    • /
    • 2014
  • Background: Breast cancer is the second leading cause of cancer death for women in the United States. Differences in survival of breast cancer have been noted among racial and ethnic groups, but the reasons for these disparities remain unclear. This study presents the characteristics and the survival curve of two racial and ethnic groups and evaluates the effects of race on survival times by measuring the lifetime data-based half-normal model. Materials and Methods: The distributions among racial and ethnic groups are compared using female breast cancer patients from nine states in the country all taken from the National Cancer Institute's Surveillance, Epidemiology, and End Results cancer registry. The main end points observed are: age at diagnosis, survival time in months, and marital status. The right skewed half-normal statistical probability model is used to show the differences in the survival times between black Hispanic (BH) and black non-Hispanic (BNH) female breast cancer patients. The Kaplan-Meier and Cox proportional hazard ratio are used to estimate and compare the relative risk of death in two minority groups, BH and BNH. Results: A probability random sample method was used to select representative samples from BNH and BH female breast cancer patients, who were diagnosed during the years of 1973-2009 in the United States. The sample contained 1,000 BNH and 298 BH female breast cancer patients. The median age at diagnosis was 57.75 years among BNH and 54.11 years among BH. The results of the half-normal model showed that the survival times formed positive skewed models with higher variability in BNH compared with BH. The Kaplan-Meir estimate was used to plot the survival curves for cancer patients; this test was positively skewed. The Kaplan-Meier and Cox proportional hazard ratio for survival analysis showed that BNH had a significantly longer survival time as compared to BH which is consistent with the results of the half-normal model. Conclusions: The findings with the proposed model strategy will assist in the healthcare field to measure future outcomes for BH and BNH, given their past history and conditions. These findings may provide an enhanced and improved outlook for the diagnosis and treatment of breast cancer patients in the United States.

Effects of Particle Size Distribution on The Magnetic Properties of Hexagonal Sr-Ferrite (육방정 Si-폐라이트의 자기적 특성에 미치는 입도 분포의 영향)

  • Song, Chang-Yul;Shin, Yong-Deok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1314-1316
    • /
    • 1994
  • $0.36[wtx]Sio_2$ and $0.1[wtx]H_3BO_3$ were added to strontium ferrite magnets of the magnetoplumbite phase SrO $5.7Fe_2O_3$. This experiment was carried out to investigate the effects of particle size distribution as a function of milling time(20,30,40,50,60,70 hours) on the magnetic properties of SrO $5.7Fe_2O_3$ ferrite magnet. The B-H Curve, density and the degree of orientation were measured. The optimal conditions of making magnets and properties of a typical sample are the following : The milling time was 60 hours. Magnetic and physical properties are $B_r$=4000[G], $_BH_c$=3330[Oe], $_IH_c$=3525[Oe], (BH)max=3.786 [MGOe], density= $5.0063g/cm^2$, orientation factor f=0.813.

  • PDF

Optimal Design of Interior Permanent Magnet Synchronous Machines Consideration of Magnet BH Characteristic with Different Rotor Type using Response Surface Methodology (반응표면분석법을 이용한 영구자석의 형상 및 특성에 따른 매입형 영구자석 동기기의 최적 설계)

  • Im, Young-Hun;Jang, Seok-Myoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1080-1089
    • /
    • 2013
  • Interior Permanent Magnet Synchronous Machines (IPMSMs) with rare earth magnet are widely used in electric vehicles and hybrid electric vehicles. IPMSMs having high efficiency, high torque, and a wide speed range are employed in propulsion system. And the rotor in an IPMSM is generally made of a rare earth magnet to achieve a large energy product and high torque. This paper discusses issues regarding design and performance of IPMSMs using different factors of BH magnetic characteristic. It is necessary to choose factors of magnetic material according to permanent magnet shape in rotor for high performance. Response Surface Methodology (RSM) is selected to obtain factors of magnetic material according to variety of rotor shapes. The RSM is a collection of mathematical and statistical techniques useful for the analysis of problems in which a response of interest in influenced by several variables and the objective is to optimize response. Therefore, it is necessary to analyze the torque characteristics of an IPMSM having magnet BH hysteresis curve with different rotor shape. Factors of residual flux density (Br) factor and intrinsic coercive force (Hc) are important parameters in RSM for rotor shape. The rotor shapes for IPMSMs having magnet BH characteristic were investigated using the RSM, and three shapes were analyzed in detail using FEA. The results lead to design consequence of IPMSMs in the various rare earth magnet materials.

Recycling of Waste Barium Hexaferrite Magnets (Barium Hexaferrite 폐자석의 재활용)

  • 박인용
    • Resources Recycling
    • /
    • v.9 no.2
    • /
    • pp.18-25
    • /
    • 2000
  • Magnetic and physical properties of sintered bodies prepare from waste sintered barium hexaferrite magnets which were come from fabrication process of isotropic permanent magnets were investigated. The properties of the sintered bodies were characterized by XRD, XRF, SEM, and BH curve tracer. After the waste permanent magnets were milled and granulated, the granules of the waste permanent magnet powders and the commercial granules were mixed with various proportions, pressed, and sintered. although the magnetic properties were decreased gradually with the content of waste magnet powder, the magnetic characteristics of the sintered magnets at $1150~1200^{\circ}C$ were comparable to those required for isotropic permanent magnets.

  • PDF

Analyses of Mesh Selectivity in Trawl Cod - end for Priacanthus macracanthus (홍치에 대한 트롤 끝자루의 망목선택성 분석)

  • Kim, Sam-Kon;Youm, Mal-Gu;Park, Chang-Doo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.8 no.1
    • /
    • pp.41-47
    • /
    • 1996
  • The fishing experiment was carried out in order to analyses the mesh selectivity for trawl cod - end in the Southern Korean Sea and East China Sea from June,1991 through December, 1992. The mesh selectivity was examined for the five kinds with opening mesh size, of which having mesh s izes 51.2mm, 70.2mm, 77.6mm, 88.0mm and 111.2mm. In this report, mesh selectivity were taken analyses trawl cod - end for Priacanthus macracanthus. The main results obtained were as follows : 1. The relation equations between total length(TL) and body height(BH), body girth(BG) and body weight(BW) were BH=0.256 TL+2.963, BG=0.620 TL+8.650 and $BW=7.34{\times}10^{-5}TL^{2.6956}$, respectively. 2. 50% selection length and selection factor of trial cod - end with opening mesh size having 51.2mm, 70.2mm, 77.6mm, 88.0mm were 94.8mm, 1.85 ; 159mm, 2.27 ; 204mm, 2.09 ; 217.3mm, 2.18, respectively. 3. Range of opening mesh size from 51.2mm to 88.0mm, parameters of master curve were slope 2.70, intercept - 5.7 and selection factor 2.11.

  • PDF

Determination of Selenium in Foods by HG-AAS (HG-AAS에 의한 식품 중의 셀렌의 정량에 대한 연구)

  • Ki-Won Cha;Sang-Ho Park;Jae-Sung Choi
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.12
    • /
    • pp.891-897
    • /
    • 1994
  • A method has been investigated for the determination of Selenium in Ginseng radix, Ganoderma Lucidum and Garlic using hydride generation atomic absorption spectrometry (HG-AAS). The effects of several acids and sodium tetrahydroborate concentration and their flow rate on the determination of Selenium for the hydride generation were investigated. The method of sample decomposition was also investigated using various mineral acids, such as nitric, perchloric and sulfuric acid in the closed system and foreign ion effects were studied. In the optimum conditions, we obtained calibration curve in the range 0-40 ppb. The analytical data of Garlic, Ganoderma Lucidum and Ginseng radix are 289, 296, 198 ppb, respectively.

  • PDF

Experimental Measurement of Magnetic Properties of a Toroidal-type Bulk Electrical Steel using B-waveform Control (자속밀도 파형제어에 의한 토로이달 벌크 전기강의 자기특성 측정)

  • Eum, Young-Hwan;Koh, Chang-Seop;Hong, Sun-Ki;Shin, Pan-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.869-875
    • /
    • 2007
  • Magnetic properties of electrical steel are, in general. measured by using Epstein frame or single sheet tester (SST). These methods, however, require very strict regulation of a specimen in its size and shape. thus, can not be easily applied to various types of specimen. On the other hand, a ring-test method, which measures only the isotropic properties, can be easily applied to most cases because it requires a toroidal-type specimen of arbitrary size. This method, especially, is considered as an unique available method for a bulk-type specimen. In this paper, a ring-test method is developed, and applied to the measurement of magnetic properties of a bulk-type electrical steel with a toroidal-type specimen. In the measurement, the magnetic properties and iron losses are measured and compared with each other at the both sinusoidal magnetic flux density and sinusoidal magnetic field intensity conditions under 0.2Hz and 60Hz alternating magnetic fields excitation. Through experimental measurements, a sinusoidal magnetic flux density condition is proven appropriate for the measurement of magnetic properties, including iron loss characteristics, of electrical steels.

Effect of particle size distribution on the magnetidc properties of hexagonal strontium ferrite (육방정 스트론튬 페라이트의 자기적 특성에 미치는 입도 분포의 영향)

  • 송창열;신용덕
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.324-331
    • /
    • 1995
  • 0.36[wt%l $SiO_{2}$ and 0.1[wt%] $H_{3}$B $O_{3}$ were added to strontium ferrite magnets of the magnetoplumbite phase SrO.5.7F $e_{2}$ $O_{3}$ to hinder grain growth and accelerate sintering, respectively. This experiment was carried out to investigate effect of particle size distribution as a function of milling time(20, 30, 40, 50, 60, 70 hours) on the magnetic properties of SrO.5.7F $e_{2}$ $O_{3}$ ferrite magnet. The B-H curve, density and the degree of orientation were measured. And the microstructure of ferrite magnets was examined with a SEM. The optimal conditions and properties of the typical sample are the following : The milling time was 60 hours. Magnetic and physical properties are $B_{r}$=4, 000[G], $_{b}$ $H_{c}$=3, 330[Oe], (BH)max=3.786[MGOe], $_{I}$ $H_{c}$=3, 525[Oe], density=5.0063[g/c $m^{3}$] and orientation factor f=0.813.0.813.3.3.

  • PDF

A Study on Unsaturated Zone Characterization and Feasibility of Soil Vapor Extraction at a DNAPL-contaminated Site in Korea

  • Lee, Man Na Mi;Yeo, In Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.48-55
    • /
    • 2013
  • This study aimed at characterizing unsaturated zone at the source zone area contaminated by DNAPL and investigating feasibility of soil vapor extraction (SVE). Five boreholes with three multi-level screens at the depth of 3.0~4.5 m, 5.5~7.0 m, and 8.0~12.0 m were installed at the source zone. Pneumatic tests were performed to determine the permeability of porous medium. Permeability was estimated to be 81.6 to 203.7 darcy, depending on the applied solutions, which was contradicted by grain size analysis of cored soil samples leading to 3.51 darcy. This is due to air flow through gravel pack during the early stage of pneumatic test. Pressure-drawdown curve in the late stage also well showed the leaky aquifer type, indicating air leakage to the ground. Air flow tests were also carried out to investigate air flow connectivity between multi-level wells, indicating that the horizontal air flow was well developed between the lower screens of the wells, not between the upper and middle screens due to the leakage to the surface. For the SVE test, there was no noticeable variation in TCE vapor concentration between three different test runs: 1. 8 hours daily for 5 days, 2. 24 hours together with air blowing at another well (BH1), 3. five consecutive days. Even for five-day consecutive test, total amount of removed TCE was estimated only to be as low as 46.5 g.