• Title/Summary/Keyword: BBP

Search Result 76, Processing Time 0.036 seconds

Contents character of phthalates in school supplies (학용품 중 프탈레이트류 함유특성 연구)

  • Kim, Kyeo-Keun
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.69-75
    • /
    • 2012
  • This study was performed to survey the school supplies such as pencil, eraser, notebook and color paper. Twenty-two kinds of samples were collected near the school zone, and eight kinds of phthalate which is one of the environmental hazard factors analyzed to estimate the contents characteristics of products. As the results of these research, three kinds of phthalates (BBP, DNOP and DIDP) were not detected in the selected samples. In the A group, DEHP and DINP were detected in the rage of 22%~28%, and DINP was selected 28%, 24% and 28% in the A-1, A-3 and A-4 samples, respectively. But the selected samples in the B group were detected less than 1,000 ppm as regulated level. Also, The DBP was detected 1% in the C-2 sample, and DEHP was detected 0.3% in the C-1 and C-6 samples. The DEHA was detected 0.3% in the D-3 sample. In this study, the DINP was mainly detected the eraser, therefore this kind of phthalate can be exposed through dermal exposure.

A Comparative Study of the effects of Autogenous and Xenogenic Bone grafts with PRP(Platelet Rich Plasma) technique on Periodontal Regeneration (혈소판 농축 혈장과 혼합된 자가골 및 이종골 이식재가 치주 조직의 재생에 미치는 효과)

  • Kim, Dong-Gi;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.499-508
    • /
    • 2004
  • Regeneration of Periodontium with PRP does not only improve regeneration rate and density of bone but have a possibility to estimate faster healing process for soft tissue. And also, autogenous bone and xenogenic bone graft are effective on regeneration of periodontium. The purpose of this study is to evaluate the effectiveness of autogenous bone and xenogenic bone $(BBP^{(R)})$ grafts with the PRP technique on regeneration of periodontium. 52 Generally healthy Pt. who had pocket depth 5mm at any of 6 surfaces of the teeth were in the study at Dept. of Perio. in Dankook Dental Hospital. Open Flap was treated for 18 infra-bony pockets as control group, autogenous bone with PRP was inserted for 25 infrabony pockets as first test group, and $(BBP^{(R)})$ with PRP was inserted for 22 infrabony pockets as 2nd test group. Then evaluation was made after 3 and 6 months 1. There were significant differences between average probing pocket depth and clinical attachment level of 3, 6 months and minimal and maximal attachment level after 6 months each other. 2. There were significant differences in average probing pocket depth of control group and 2nd experimental group between 1 and 6 months. For clinical attachment level and minimal and maximal proving attachment level, there was a significant difference after 6 month of surgery. 3. There was no significant difference between two test groups for average probing depth, clinical attachment level, and minimal and maximal probing attachment level. As the result, PRP with bone graft could be very effective for regeneration of periodontium and there was no difference between xenogenic bone and autogenous bone.

Residue levels of phthalic acid esters (PAEs) and diethylhexyl adipate(DEHA) in various industrial wastewaters (업종별 산업폐수 중 프탈산에스테르와 디에틸헥실아디페이트의 잔류수준)

  • Kim, Hyesung;Park, Sangah;Lee, Hyeri;Lee, Jinseon;Lee, Suyeong;Kim, Jaehoon;Im, Jongkwon;Choi, Jongwoo;Lee, Wonseok
    • Analytical Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.57-64
    • /
    • 2016
  • Many phthalic acid esters (PAEs), including DMP, DEP, DBP, BBP, and DEHP, as well as DEHA are widely used as plasticizers in plastics. An analytical method was developed and used to analyze these compounds at 41 industrial facilities. The coefficient of determination (R2) for each constructed curve was higher than 0.98. The method detection limit (MDL) values were 0.4–0.7 μg/L for PAEs and 0.6 μg/L for DEHA. In addition, the recovery rate was shown to be 77.0–92.3%, while the relative standard deviation was shown to be in the range of 5.8-10.5%. DMP (n = 3), DEP (n = 2), DBP (n = 2), BBP (n = 2), and DEHA (n = 3) were detected in the range of 2.2-11.1% in the influent. DEHP was a predominant compound and was detected at > MDL in both the influent (n = 16, 35.6%) and the effluent (n = 4, 10.0%) at a high removal efficiency (92–100%). The highest levels of residue in industrial wastewater influent were 137.4 μg/L of DEHP at plastic products manufacturing facility, 12.5 μg/L of DEHA at a chemical manufacturing facility, and 14.0 μg/L of DEP at an electronics facility. The highest concentration of effluent was 12.5 μg/L of DEHP at a chemical manufacturing facility, which indicated that the effluent was below the allowable concentration (800 μg/L). Therefore, the levels of PAEs and DEHA that are discharged into nearby streams could not influence the health of the ecosystem.

Case Study on Determination of the Level of New RoHS II Substances in Domestic Electronic and Electrical Equipments (국내 전기전자 제품에 함유된 신규 RoHS II 물질 검출 사례 연구)

  • Song, Moon-Hwan;Son, Seung-Hwan;Cho, Young-Dal;Choe, Eun-Kyung
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.124-133
    • /
    • 2011
  • In addition to six substances regulated in EU RoHS including lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE), priority substances are identified in new RoHS II as hexabromocyclododecane (HBCDD), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP) and diethylhexyl phthalate (DEHP). In this study, 20 plastic samples were collected from 12 domestic electrotechnical companies and levels of four restricted substances were determined by gas chromatography-mass spectrometry, Among 20 parts that compose washer, refrigerator or microwave oven, HBCDD was detected in three samples of NBR material with the amount of 42~381 mg/kg while DBP and BBP was not detected in any samples collected respectively, implying that these substance may not be used widely in plastic materials for EEE. However, DEHP was detected in all samples of NBR, PP, PBT, EPDM and PVC materials with the amount of 42 up to 59,400 mg/kg that exceeds the limit value of 0.1 wt% (1,000 mg/kg). Presence of a restricted substance in polymer material makes a great negative influence on a number of final product. To cope with coming RoHS II as well as REACH, action not to use DEHP in plastic material or the relevant notification in case of REACH seems to be needed. Screening test of Arsenic compounds such as diarsenic pentaoxide, diarsenic trioxide, lead hydrogen arsenate, triethyl arsenate that are included in REACH SVHC was done by ICP measurement Arsenium was detected in four samples made of NBR and PBT materials in the level of 15~700 mg/kg. By considering the screening method used in this study, the amount of arsenium compounds in the thermistor made of PBT material has a high chance of exceeding the regulated limit value.

Design of Visualization Tool for Snowboard Motion (스노보드 동작 시각화를 위한 설계)

  • Park, Myeong-Chul;Kim, Kang
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.01a
    • /
    • pp.41-42
    • /
    • 2013
  • 본 논문에서는 키넥트 센서에 의해 획득한 스켈레톤 정보를 이용하여 스노보드 동작을 시각화 할 수 있는 도구를 설계한다. 스노보드 동작에서 가장 기본이 되는 동작은 BBP(Balanced Body Position)자세로서 안정된 턴 동작을 위한 기본 기술이다. 키넥트 센서로 부터 획득한 좌표정보를 이용하여 발목, 무릎, 엉덩이 관절의 각도와 몸의 중심축을 추적하여 표준 자세와 비교분석한다. 본 연구결과는 향후 스노보드 턴 동작을 시각화하는 도구의 기초자료로 활용될 수 있을 것이다.

  • PDF

Determination of Phthalates Compounds in the Ambient Atmosphere (I) - Evaluation of a Measurement Method and its Application to a Field Study - (환경대기 중 프탈레이트 화합물의 농도 측정 (I) - 측정방법 평가와 현장 적용 -)

  • Hwang, Yoon-Jung;Park, Young-Hwa;Seo, Young-Kyo;Seo, Gwang-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.443-454
    • /
    • 2010
  • Phthalate compounds are widely used as plasticizers in polyvinyl chlororide (PVC) resins and other industrial consumer products, and some of them are known to be endocrine disruptors. In Korea, a number of studies have been carried out for the measurement of phthalates in consumer products and drinking water. However, no data are available for those compounds in the ambient air where the general public are routinely exposed. In this study, we evaluated sampling and analytical methods for the determination of phthalates in the ambient atmosphere. A wide range of phthalates compounds were included in the target analytes, which are dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), and di-n-octyl phthalate (DOP). Most of samples were collected using a high volume sampler with a PUF/XAD-2 column/quartz fiber filter and then analyzed by GC/MS. Some of samples were simultaneously collected on XAD-2 using a low-volume sampler, together with high-volume samples. The analytical method applied in this study showed good repeatability and linearity. Quantitative detection limits were estimated from 0.60 to 17.84 ng/$m^3$ in air, depending on individual compounds. The field measurements were carried out at 3 sites located in Sihwa- Banwall industrial areas and a suburban area from January 2007 to November 2007. From the field experiments, DEHP, DMP and DBP appeared to be the most abundant compounds in the ambient air. It was also found that DMP, DEP and DBP were mainly distributed in the vapor phase, while BBP, DEHP and DOP were predominantly associated with the particulate phase. The concentrations of DEHP and DMP in the industrial areas ranged from 45.7 to 1,012.7 ng/$m^3$ and from 7.7 to 375.1 ng/$m^3$, respectively. Overall, the high-volume sampling method was demonstrated to be superior to the low-volume method for the determination of phthalates in the ambient atmosphere.

The analysis of endocrine distruptors in commercial cosmetics (유통 화장품 중 내분비계 장애물질 탐색 및 규명에 관한 연구)

  • Koo, Heesoo;Na, Youngran;Lee, Seungju;Min, Sangkee;Kang, Jungmi;Jin, Sung Hyun
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.212-220
    • /
    • 2015
  • This study aims to identify the characteristics of phthalates (DMP, DEP, DBP, DEHA, BBP, DEHP, and DNOP) and heavy metals such as lead (Pb), cadmium (Cd), and mercury (Hg) in cosmetics and their containers. Phthalates and heavy metals may be endocrine distruptors. Sixty-five cosmetics were purchased from online and offline stores in Busan. This study developed a simultaneous method for the analysis of phthalates by GC-FID. The results showed that among the 65 cosmetics, DBP, DEHP, and DEP were detected at 20.0%, 7.7%, 1.5%, respectively. The amounts of DBP and DEHP detected in 18 samples were less than 100 μg/g, which satisfies the Regulations of Cosmetic Safety Standards in Korea. In order to detect phthalates in cosmetic containers, a dissolution test was conducted by extracting solutions, such as water, n-heptane, 20% ethanol, 50% ethanol and 4% acetic acid, which were prepared with different levels of pH, alcohol content, and fat content following the Korea Standards and Specifications for Utensils, Containers, and Packaging. The results showed that DMP, DBP, DEHA, BBP, DEHP, and DNOP were not detected, DEP was detected in plastics such as PE, PP, and others, when a 50% alcohol solvent was used. Phthalates may not be detected in cosmetic containers if they are not packaged with the above 20% alcohol constituent. We also analyzed the concentration of heavy metals, such as Pb, Cd, and Hg, by using ICP-OES and a mercury analyzer. The ranges of concentration were ND~2.71 μg/g for Pb, ND~0.31 μg/g for Cd, and ND~0.01 μg/g for Hg, which are below the regulated level.

A Histo-Pathological Study of Effect on Bone Regeneration with Fibrin Adhesive (이종골 이식시 Fibrin adhesive의 사용이 골 재생에 미치는 영향에 관한 조직병리학적 연구)

  • Ko, Young-Woo;Lim, Sung-Bin;Chung, Chin-Hyung;Lee, Chong-Heon
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.91-102
    • /
    • 2003
  • Several effective treatment methods and materials have been developed for the treatment of furcation involvement. Currently, the combination of guided tissue regeneration (GTR) and bone grafts is the most commonly prescribed method of treating furcation involved defects. But because these cases often present with poor accessibility, placement of the membrane may be difficult and consequently, clinically impractical. In this study, the alveolar bone healing patterns of adult beagle dogs presenting with alveolar bone destruction treated by one of two methods - treatment using solely bone allografts (BBP(R)), or treatment using bone allografts (BBP(R)) stabilized by a fibrin adhesive - were comp ared. The effects of the fibrin adhesive on the initial stabilization of the newly formed bone, subsequent regeneration of bone, and the feasibility of the clinical application of the fibrin adhesive were analyzed. The results of the study were as follows: 1. Clinical signs of inflammation at the 4-8 week interval were not observed: but signs of mild inflammation were histologically observed at the 4-week interval. 2. Allografts stabilized by fibrin adhesive showed good bone formation, whereas defects treated with only the allograft material showed incomplete alveolar bone regeneration. 3. Allografts stabilized by fibrin adhesive showed a decrease in the amount old bone with a concurrent increase in the formation of new lamellar bone four weeks post-op, whereas defects treated with only the allograft material showed no new lamellar bone formation at the same interval. 4. In detects treated with only the allograft material, the defective area was filled with connective tissue 8-weeks post-op, whereas fibrin adhesive stabilized allografts showed viable connections between the original bone and the newly formed bone, in addition to neovascularization 8-weeks post-op. The results of this study show that concurrent use of fibrin adhesive materials can stabilize the allograft material and aid in new bone formation Although the stability of fibrin adhesives fall short of the results achievable by GTR membranes, in cases presenting with poor accessibility that contraindicate the use of membranes, fibrin adhesive materials provide a viable and effective alternative to graft stabilization and new bone formation.

Comparison of the Short Term Toxicity of Phthalate Diesters and Monoesters in Sprague-Dawley Male Rats

  • Kwack, Seung-Jun;Han, Eun-Young;Park, Jae-Seok;Bae, Jung-Yun;Ahn, Il-Young;Lim, Seong-Kwang;Kim, Dong-Hyun;Jang, Dong-Eun;Choi, Lan;Lim, Hyun-Jung;Kim, Tae-Hyung;Patra, Nabanita;Park, Kui-Lea;Kim, Hyung-Sik;Lee, Byung-Mu
    • Toxicological Research
    • /
    • v.26 no.1
    • /
    • pp.75-82
    • /
    • 2010
  • This study was carried out to investigate the short term toxicity of nine phthalate diesters including di-2(ethylhexyl) phthalate (DEHP), di(n-butyl) phthalate (DBP), di-n-octyl phthalate (DnOP), diethyl phthalate (DEP), butylbenzyl phthalate (BBP), dimethyl phthalate (DMP), di-isodecyl phthalate (DIDP), diundecyl phthalate (DUP), and di-isononyl phthalate (DINP) and five phthalate monoesters including mono- (2-ethylhexyl) phthalate (MEHP), monobutyl phthalate (MBuP), monobenzyl phthalate (MBeP), monoethyl phthalate (MEP), monomethyl phthalate (MMP) and phthalic acid (PA) in Sprague-Dawley male rats. Animals were administered 250 mg/kg/day (monoesters and PA) or 500 mg/kg/day (diesters) of phthalate for two weeks. All animals were examined for body and organ weights, blood hematology, serum biochemistry, and urine analysis. The body weight gain was significantly lower in rats treated with BBP, DBP, DINP, MEHP, MBuP, and PA than that of control. Liver weights were significantly increased in the DEHP, DBP, DnOP, DIDP, and MEHP groups as compared to the control group. Testes weights were significantly decreased only in the DEHP-, DnOP-, and DIDP-treated groups as compared to the control. Significant differences in hematological changes were not observed in any treatment groups. Significant increases in blood glucose levels were observed in the DEHP, MEHP, and MBeP groups. Aspartate aminotransferase (AST) levels were significantly increased in the DBP, DUP, DINP, MBuP, and MBeP groups, whereas alanine aminotransferase (ALT) levels were significantly increased only in the DEHP and MEHP groups. Serum ALP levels were significantly higher in phthalate diester (500 mg/kg/day)-treated rats as compared to control. However, the total cholesterol level was significantly reduced in the DEHP- and DIDP-treated groups, whereas serum triglyceride (TG) levels were higher in the DINP-, MEHP-, and MBuP-treated groups. These results suggest that short term toxicity of phthalate monoesters produces adverse effects as similar to phthalate diesters in Sprague-Dawley rats.

A study on the development of phthalate plasticizers CRM in ABS resin (ABS 중 phthalates 가소제 CRM 개발에 대한 연구)

  • Jung, Jung-Sul;Park, Jung-Woo;Yoo, Seok;Kweon, Seong-Il;Hong, Sung-Taeg;Sun, Yle-Shik;Park, Cheon-Min;Choi, Chang-Hyoo
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.273-283
    • /
    • 2012
  • Phthalate plasticizers are regulated by RoHS, REACH and CPSC as hazardous substances. Responding to these international environmental restrictions, we developed ABS certified reference material (CRM) for determination of phthalate plasticizers such as DMP, DEP, DBP, BBP, DEHP and DnOP. The candidate material has been made with ABS resin widely used in electric and electronic products and 6 kinds of phthalate plasticizers. The making of the material involved a series of processes like extruding, cooling, pelletizing, and drying using twin screw extruder. Then it has been certified according to ISO Guide 35. Using isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS), homogeneity, short-term stability, and long-term stability were evaluated. The certified values were determined by using primary reference material (PRM) of KRISS for traceability. From now on, we will provide ABS CRM to national and international companies and research institutes after certification as certified reference material and registering on COMAR (code of reference material).