• 제목/요약/키워드: BARS

검색결과 2,225건 처리시간 0.029초

고강도철근(550MPa)의 원전구조물 적용을 위한 표준갈고리 정착설계 (Development Length of High-Strength Standard Hooked Bars (550MPa) in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2018
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, it is permitted to use the high-strength(550MPa) hooked bars in design of development length, but there is no special equation for high-strength bars. In order to reflect the anchorage capacity and behavior properties of high-strength bars with large-diameter(43 & 57mm), it is necessary to develope the new development length equation for large-size and high-strength bars.

  • PDF

한국산 목림식물에 대한 계통분류학적 연구 - 목련과, 붓순나무과 및 오미자과의 비교목부해부 - (Systematic Studies on Some Korean Woody Plants - A Comparative Wood Anatomy of Magnoliaceae, Winteraceae and Schizandraceae -)

  • 소웅영
    • Journal of Plant Biology
    • /
    • 제28권4호
    • /
    • pp.271-284
    • /
    • 1985
  • Anatomical characters of secondary xylem in the trunk of Magnoliaceae, Winteraceae and Schizandraceae, including six genera and eleven species grown naturally in Korea, were studied to elucidate the relationship between genera or families. It is considered that among these families specialization in the perforation plate, the angel of end wall to the vessel axis, and diameter of vessel element, is in the order of Winteracae, Magnoliaceae, and then Schizandraceae. In Winteraceae, vessel elements have wholly scalariform perforation plates with very numerous bars. Among Magnoliaceae the peroration plates are scalariform with very numerous bars in Michelia, with few bars in Liriodendron, and with few bars or simple in Magnolia. In Schizandraceae, Schizandra shows scalariform perforation plates with few bars or simple perforation plates, and Kadsura shows almost simple ones.

  • PDF

수직으로 비접촉 겹침이음된 철근의 이음성능에 관한 해석적 연구 (Analytical Study on Splice Performances with the Vertical Noncontact Lapped of Reinforcing Bars)

  • 이호진;김승훈;하상수;문정호;이리형;이용택
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.171-174
    • /
    • 2005
  • In this study, new moment-resisting precast concrete beam-column joint is proposed for moderate seismic regions. It has the connection reinforcing bars, penetrated the joint and lap-spliced with the bottom bars of precast U-beam. To evaluate the performance for noncontact lapped splice, analytical works were conducted. Major variables for FEM analysis are the length of lap, the diameter of connection reinforcing bars, and the distance between lapped bars. The results of this study show thar the these variables has much influence on strength and deformation of lapped joint.

  • PDF

Behavior of Mechanical Anchorage of Bars Embedded in Concrete Blocks

  • You, Young-Chan;Park, Keun-Do;Kim, Keung-Hwan;Lee, Li-Hyung
    • KCI Concrete Journal
    • /
    • 제14권2호
    • /
    • pp.86-91
    • /
    • 2002
  • This paper presents an experimental study to investigate the behavior of mechanical anchorage of reinforcing bars in concrete members. Three kinds of mechanical anchorage which are a kind of headed reinforcements are considered in this study. Total seven specimens were prepared to consider the effects of anchoring methods (Type A, Type B and Type C) and anchorage lengths of the reinforcing bars (14 $d_{b}$, 12 $d_{b}$, 9 $d_{b}$). Pullout tests conforming to ASTM were carried out to assess the effects of several variables on anchoring strength of bars. Based on the test results, it was concluded that the behavior of the specimen anchored by the mechanical anchorage with the anchor-age length of 12 $d_{b}$, is as good as, or better than that of the specimen anchored by 90-degree standard hook.rd hook.

  • PDF

고강도철근(550MPa)의 원전구조물 적용을 위한 직선철근의 정착설계 (Development Length of High-Strength Straight Bars (550MPa) in Nuclear Power Plant Structures)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.110-111
    • /
    • 2018
  • Because of the congestion problems, the high-strength reinforcements are expected to be used in nuclear power plant structures in the near future. According to ACI 349-13, it is permitted to use the high-strength(550MPa) straight bars in design of development length, but there is no special equation for high-strength bars. In order to reflect the anchorage capacity and behavior properties of high-strength straight bars with large-diameter(43 & 57mm), it is necessary to find the modified factor or develop the new development length equation for large-size and high-strength bars.

  • PDF

RC beams retrofitted using external bars with additional anchorages-a finite element study

  • Vasudevan, G.;Kothandaraman, S.
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.415-428
    • /
    • 2015
  • Study on flexural retrofitting of RC beams using external bars with additional intermediate anchorages at soffit is reported in this paper. Effects of varying number of anchorages in the external bars at soffit were studied by finite element analysis using ANSYS 12.0 software. The results were also compared with available experimental results for beam with only two end anchorages. Two sets of reference and retrofitted beam specimens with two, three, four and five anchorages were analysed and the results are reported. FE modeling and non-linear analysis was carried out by discrete reinforcement modeling using Solid65, Solid45 and Link8 elements. Combin39 spring elements were used for modeling the frictional contact between the soffit and the external bars. The beam specimens were subjected to four-point bending and incremental loading was applied till failure. The entire process of modeling, application of incremental loading and generation of output in text and graphical format were carried out using ANSYS Parametric Design Language.

Seismic behavior evaluation of exterior beam-column joints with headed or hooked bars using nonlinear finite element analysis

  • Rajagopal, S.;Prabavathy, S.;Kang, Thomas H.K.
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.861-875
    • /
    • 2014
  • This paper studies the response of seismic behavior of reinforced concrete exterior beam-column joints under reversal loading with different anchorages and joint core details. The joint core was detailed without much confinement (group-I) and/or with proposed X-cross bars in the core (group-II). The beam longitudinal reinforcement's anchorages were designed as per ACI 352 (headed bars), ACI 318 (conventional $90^{\circ}$ bent hooks) and IS 456 ($90^{\circ}$ bent hooks with extended tails). The nonlinear finite element analysis response of the beam-column joints was studied, along with initial and progressive cracks up to failure. The experimental and analytical results were compared and presented in this paper to make more scientific conclusions.

터빈 발전기용 비열화 고정자 권선 바의 절연 특성 (Insulation Properties of Unaged Stator Winding Bars for Turbine Generators)

  • 김태희;강명국;이재권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2097-2099
    • /
    • 2005
  • Class-F and class-B insulating materials based on the resin rich type mica-epoxy composites for the stator windings in large turbine generators have been developed by DHIC. In recent, stator winding bars applied with prototype insulation tapes and commercially available resin rich groundwall tapes were produced through the same manufacturing processes as the real bars. Comparative tests to obtain the insulation properties of both bars were carried out such as IR/PI. dissipation factor and partial discharge at room temperature. In this paper, the manufacturing processes and the insulation properties of the bars which were not aged are presented.

  • PDF

한정연성도 설계를 위한 소수 겹침이음을 갖는 주철근 상세에 관한 연구 (Less amout of lap-spliced longitudinal bars as an alternative of seismic detailing for limited ductility design)

  • 김익현;이종석;김원섭;선창호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.255-262
    • /
    • 2003
  • In present Korea Highway Bridge Standards the lap splice of longitudinal bars in a potential plastic hinge region is allowed so that large amount of transverse rebar specified in high seismicity regions Is required to prevent brittle bond failure If the brittle failure effects can be completely removed from the conventional designed piers, the amount of transverse rebar will be reduced drastically. In this study scaled models with solid and hollow rectangular sections were tested to investigate the seismic behavior of RC piers with 50% of lap-spliced longitudinal bars in plastic hinge regions. In the tests the typical flexural failure conducting a ductile behavior were observed in both models. It is shown that the 50% of lap-spliced bars can be considered as a good alternative of seismic detailing for longitudinal bars.

  • PDF

ACI 318-19 변경에 따른 확대머리철근 정착설계의 영향분석 (Study on the Effect on the Development Design of Headed Deformed Bars by change of ACI 318-19)

  • 이병수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.110-111
    • /
    • 2019
  • In ACI 318-19 published recently, the conditions and development length equation to use the headed deformed bars were changed considerably. Although the use of the larger-diameter(No.14 and 18) headed deformed bars isn't yet permitted, the use of the high strength(80,000psi) headed deformed bars is permitted and the effect of bar-diameter($d_b$) on the development length is increased considerably. Therefore, structures using larger-diameter headed deformed bars will be expected to be affected by this code change. We will study the effect of the code change on the development design and find out the design optimization method to minimize the effect of the changed conditions and development length equation.

  • PDF