Roll Pass Design System for Round Bars to Design Rolling Equipment (압연 설비 설계를 위한 봉재 압연의 롤 패스 설계 시스템)

  • 윤성만;박승희;신상엽
    • Transactions of Materials Processing
    • /
    • v.9 no.2
    • /
    • pp.112-119
    • /
    • 2000
  • The roll Pass design is one of the most important processes to design the whole equipment of the rods and bars rolling system. In this study, the roll pass design program named TollRo(Rolling Factory Organizer) was developed. conventional methods to design roll pass were analyzed and a new algorithm to design the dimension of the intermediate groove was introduced. Object oriented programming technology was implemented in this design program. It comprises GUI(Graphic User Interface), function of automatic pass design, function of modifying pass schedule and database of material properties. The developed program can be used to design roll pass with consistency for the rods and bars rolling system. The man-hours for the whole design can be drastically reduced. The design parameters of rolling system can be extracted quickly by this program.

  • PDF

Lap Splice Strength of Reinforcing Bars on the Relitive Rib Area (상대마디면적에 따른 이형철근의 겹침이음 강도)

  • Park, Sung-Gyu;Hong, Geon-Ho;Choi, Dong-Uk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.307-310
    • /
    • 2005
  • The effects of deformation properties on the bond of steel reinforcing bars to concrete are experimentally studies to expect the lap splice strength. Based on the previous research about relative rib area, lap splice strength between reinforcing bars and concrete can be improved by the control of rib height and spacing. This paper describes the testing and analysis of 15 beam-spliced specimens containing D25, D22, D19 with relative rib areas ranging from 0.066 to 0.162. The tests are analyzed to determine the effect of relative rib area(Rr) on the increase in bond strength. The tests also provide a preliminary indication of the effect of high relative rib area on the splice strength of uncoated bars.

  • PDF

A Study on Application of Automated Inspection System for Rebar Inspection using 3D Scanner (3D 스캐너를 활용한 철근 자동검측방식의 현장적용성 연구)

  • Lim, Hyun-Su;Kim, Tae-Hoon;Lee, Myung-Do;Kim, Chang-Won;Cha, Min-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.157-158
    • /
    • 2019
  • Reinforcing bars are an important material for tensile strength of structures. For this reason, the inspection of the reinforcing bars confirming the layout and omission is very important for the safety of the structures. However, the current method of inspecting of the reinforcing bars through photographs of specific areas is difficult to identify condition all reinforcing bars. And It is also difficult to confirm after completion of a building. Therefore, reinforcing bar inspection using 3D scanner is required for automation of rebar inspection and database construction. For this purpose, this study test application of automated inspection method for rebar inspection using 3D scanner and discuss the effect of this method.

  • PDF

ASME-CC Code Change to use the Gr.80 Shear Reinforcement in Nuclear Power Plant Structure (원전구조물의 Gr.80 전단철근 사용을 위한 ASME-CC 코드개정에 관한 연구)

  • Lee, Byung-Soo;Lim, Sang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.9-10
    • /
    • 2015
  • Generally significant reinforcement is used in nuclear power plant structures and may cause potential problems when concrete is poured. In particular pouring concrete into structural member joint area is more difficult than other areas since the joint area is very congested due to the crossed bars and the embedded plates, The purpose of this study is to solve these problems by applying Gr.80(550MPa) shear bars to containment structures of nuclear power plant. In order to apply them to containment structures, it is necessary to change ASME-CC code (ASME Sec.III Div.2). The structural performance tests of wall & beam have been done to compare Gr.80(550Mpa) with Gr.60(420MPa) shear bars. The test results and code change proposal were presented to ASME-CC Committee last year and the discussion for code change will be expected to proceed in the near future.

  • PDF

A computational platform for seismic performance assessment of reinforced concrete bridge piers with unbonded reinforcing or prestressing bars

  • Kim, T.H.;Park, J.G.;Kim, Y.J.;Shin, H.M.
    • Computers and Concrete
    • /
    • v.5 no.2
    • /
    • pp.135-154
    • /
    • 2008
  • This paper presents a nonlinear finite element analysis procedure for the seismic performance assessment of reinforced concrete bridge piers with unbonded reinforcing or prestressing bars. A computer program named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology) is used to analyze reinforced concrete structures; this program was also used in our study. Tensile, compressive and shear models of cracked concrete and models of reinforcing and prestressing steel were used account for material nonlinearity of reinforced concrete. The smeared crack approach was incorporated. To represent the interaction between unbonded reinforcing or prestressing bar and concrete, an unbonded reinforcing or prestressing bar element based on the finite element method was developed in this study. The proposed numerical method for the seismic performance assessment of reinforced concrete bridge piers with unbonded reinforcing or prestressing bars is verified by comparison of its results with reliable experimental results.

Development of Hybrid Fiber Reinforced Polymer Reinforcing Bars and Evaluation of the Bond Properties (하이브리드 FRP 보강근의 형상개발과 부착성능 평가)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.629-632
    • /
    • 2006
  • The various rib geometry of hybrid fiber reinforced polymer (FRP) reinforcing bars were analyzed by finite element method. From the analysis result, two types of hybrid FRP reinforcing bars such as spiral and cross type with the same dimension of rib geometry were fabricated in this study. To evaluate the bond properties of them, direct pull-out test was performed. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made in accordance with the recommendations of CSA Standard S806-02. From the test results, it was found that cross type hybrid FRP reinforcing bars showed the highest bond strength than that of the others due to the higher relative rib area.

  • PDF

A Study on Characteristics of Objects Appeared in Interior Spaces of Contemporary Restaurants and Bars (현대 식음공간에 나타난 오브제의 표현특성에 관한 연구)

  • An, Ju-Hui;Lyu, Ho-Chang
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.184-189
    • /
    • 2008
  • The change in a society have brought about other changes in the overall areas of culture and art. And have brought the advent of "object", which is a unique cultural aspect. The object became a trend of the world in a culture and art. This trend has satisfied the modern people who have look for new visual stimulation. The object appears well in the spaces restaurants and bars where are reflected in consumer's needs and change of life pattern. The reason is that the spaces restaurants and bars have expressed the differentiated and individualized image with the characteristic of the times. There are three types of the expressed characteristics of objects in interior design. These are visual, functional, and emotional characteristics. But in this study it could not be found that it characterized with one concrete vocabulary and concept. Therefore, it is need to understand the various tendency which expressed characteristics of objects in the spaces restaurants and bars.

  • PDF

Performance of the Squirrel Cage Induction Motor with High Temperature Superconducting Rotor Bars at Stable Operating Region (고온초전도단락봉을 사용한 농형유도전동기의 안정영역 특성)

  • 심정욱;차귀수;이지광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.9
    • /
    • pp.442-447
    • /
    • 2003
  • Motors with HTS wires or bulks have been developing recently. Those are large synchronous motor with HTS wires at the field winding in the rotor, hysteresis and reluctance motors with HTS bulk in the rotor. This paper presents the fabrication and test results of an HTS induction motor. Conventional end rings and short bars were replaced with HTS wires in the motor. Stator of the conventional induction motor was used as the stator of the HTS motor. Rated capacity and rpm at full rotor of the conventional motor were 0.75[kW] and 1,710[rpm]. Two, HTS wires are used in parallel to make the end rings and bars. The critical current of the BSCCO-2223 HTS wire which was used in the bars and end rings were 115[A]. Electrodynamometer was coupled directly to the shaft of the rotor with HTS wires.

Disease Symptom and Effect of Water Potential on Mycelial Growth of Botryosphaeria dothidea Associated with Chestnut Tree (Botryosphaeria dothidea에 의한 밤나무의 병징과 병원균의 균사생장에 미치는 Water Potential의 효과)

  • Sung Jae Mo;Han Sang Sup
    • Korean Journal Plant Pathology
    • /
    • v.3 no.1
    • /
    • pp.13-16
    • /
    • 1987
  • Infection rate of chestnut tree by Botryosphaeria(Dothiorella) dathidea was about $10\%$ at Gapyung area. disease symptom of chestnut did not appear in October but appeared in November, showing $50\%$ in May in ext year. B. dothidea was more pathogenic to chestnut than did Catinula sp. and Fusicoccum sp. B. dothidea uses soft rot, but Catinula sp. and Fusicoccum sp. causes dry rot. Mycelial growth of B. dothidea was optimal at $28^{\circ}C$. Mycelial growth was stimulated when water potential decreased from -2 bars to -12 bars and declined from -12 bars to -60 bars.

  • PDF

Fault Diagnosis of Rotor Bars in a Single Phase Induction Motor Monitoring Electromechanical Parameters (기전연성계 해석을 이용한 단상유도전동기의 회전자 결함진단에 관한 연구)

  • Park, S.J.;Chang, J.H.;Jang, G.H.;Lee, Y.B.;Kim, C.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.802-808
    • /
    • 2000
  • This paper characterizes the electromechanical parameters due to the fault of rotor bars in a squirrel cage induction motor. Simulation is performed to investigate how broken rotor bars have effect on them by solving the time-stepping finite element equation coupled with magnetic field equation, circuit equation and mechanical equation of motion. It shows that the asymmetry of magnetic flux due to the broken rotor bar introduces the beating phenomenon in time domain and the sideband frequencies in frequency spectra, respectively, to the stator current, torque, speed, magnetic force and vibration of a rotor. However, vibration of a rotor would be the most effective monitoring parameters to detect the faults of rotor bars.