• 제목/요약/키워드: B.t. H-14

검색결과 394건 처리시간 0.03초

소음발생 산업장에서의 청력보존프로그램 평가 (Evaluation on Hearing Conservation Program in the Noisy Industries)

  • 곽문석;이종태;김정호;엄상화;김대환;손병철;이창희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.815-829
    • /
    • 1997
  • This study was performed to assist the employer to establish the effective program for hearing conservation of noisy industry. The study subjects were health care managers of an industry and the study industries were devided into two groups(Group I, 37 industries; have the workers diagnosed as noise-induced hearing loss, Group II, 41 industries; not have the workers diagnosed as noise-induced hearing loss) and the question method carried out through the face to face interview. The contents of questionnaire for OSHA's hearing conservation program(HCP) consisted of seven components: 5 questions of monitoring of employee noise exposures(component 1), 6 questions of the institution of engineering, work practice, and administrative controls for excessive noise(component 2), 8 questions of the provision of each overexposed employee with an individually fitted hearing protector with an adequate noise reduction rating(component 3), 14 questions of employee training and education regarding noise hazards and protection measures(component 4), 9 questions of baseline and annual audiometry(component 5), 3 questions of procedures for preventing further occupational hearning loss by an employee whenever such an event has been identified(component 6), and 1 question of recording keeping(component 7), thus total numbers of questions was 46. The numbers of statistially significant difference(p<0.05) between two groups were 2(25.0%) among 8 questions of component 3, 10(71.4%) among 14 questions of component 4, 3(33.3%) among 8 questions of component 5, 2(6.7%) among 3 questions of component 6, and 17(37.0%) among total 46 questions of questionnaire. Above results showed that the level of HCP acceptance in group I was lower than in group II. Thus employer's understanding about HCP should be precede for the effective hearing conservation program of employee and the adequate hearing protector, training and education, baseline and annual audiometry, and procedures for preventing further occupational hearning loss for hearing conservation would be more emphasized.

  • PDF

마케팅 전략에 따른 리뉴얼 디자인 전개에 관한 연구 (A study on the renewal design development of marketing strategy)

  • 신홍재;함재룡
    • 디자인학연구
    • /
    • 16호
    • /
    • pp.1-14
    • /
    • 1996
  • 최근 기업에서의 마케팅 전략은 다변화하고 있으며 이런 가운데 신제품 개발 유형이 다양화되고 있다. 그 유형은 신 개념 제품개발, 혁신적 제품개발, 신 브랜드 제품개발, 기존제품 개량, 모델 체인지 개발 등을 들 수 잇다. 여기서 신제품 개발 디자인 프로세스의 과학적 접근방법의 발달로 인해 각 유형별 제품개발에 있어서 디자인 전개방법은 유사하게 진행되지만 유형에 따라 디자인 접근 또는 전략적 측면에서 다각화된 디자인 전개방법이 요구되고 있다. 그리고 성숙기에 접어든 기존 상품을 시대적 환경변화에 따라 대처하는 제품개량을 통하여 기존제품에 라이프 사이클을 연장하려면, 기업의 대내외적 환경변화에 부합되는 소비자 요구, 가치관, 기호성향에 대응할 수 있는 개선된 디자인 활용이 점점 더 중요해지고 있다. 그러나 디자인 전개기법을 활용하여 디자인된 대안이 사용자의 요구, 평가, 검증을 하는데 있어 명확한 디자인을 결정하기란 매우 어려운 실정이다. 이와 같이 문제를 인식하고 시장에서 성공한 기존상품개량에 경영적 마케팅전략을 수용하여 소비자 라이프 스타일 변화에 적극적으로 대응할 수 있는 리뉴얼 디자인 전개방법을 제시하고, 대내외부 고객의 요구를 수용하여 디자인 대안의 평가, 검증, 확인을 통한 고객만족을 통해 리뉴얼 디자인 전략을 수행할 수 있는 것이 바로 리뉴얼 디자인 전개방법이라 할 수 있다. 따라서 본 연구는 기존상품의 리뉴얼 디자인 전개과정을 통하여 급변하는 시대적 환경변화에 신속히 대응하고, 사용자의 욕구를 만족시키는 상품을 개발함과 동시에 오랫동안 지속시킬 수 있는 전략을 수반할 수 있는 리뉴얼 디자인 전개방법을 제시하는 것을 목표로 하였다.

  • PDF

한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I) (Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea)

  • 이순혁
    • 한국농공학회지
    • /
    • 제19권1호
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

화학적 단순배양액에서의 소 초기배의 발생능력 (Developmental Ability of Bovine Early Embryos in Chemically Defined Media)

  • 이홍준;서승운;정용;변태호;이상호;송해범
    • 한국수정란이식학회지
    • /
    • 제10권2호
    • /
    • pp.163-169
    • /
    • 1995
  • In the experiment I for maas production of bovine early embryos, 18~20hpi fertilized eggs (756 eggs) and parthenogenic eggs (618 eggs) which were treated by 10% ethanol were cultured in both TGM and CZB. In the experiment II, suppiment effects each in CZB and CRlaa were tested by matured and fertilized oocytes which were after 18~20hpi. In the case of experiment I after 48hr, the cleavage rates of normally fertilized eggs were 66.6% in TCM treatment and 77.7% in CZB treatment, and after 240h the blastocysts were 7.5% in TCM and 14.1% in CZB. In the parthenogenic eggs, the deavage rates at 48hr were 39.6% in TCM and 57.5% in CZB, and at 240h, the blastocysts were 0.9% in TCM and 4.4% in CZB. These results showed that the effects of CZB on developmental ability to parthenogenic eggs as well as nomally fertilized eggs are relatively high. In experiment W, the effect of exposing the cleaved embryos to CZB for 30h on the blastocyst formation was examined. Similar rates of blastocyst formation were obtained both in TCM and CZB, suggesting that CZB exposure. during ealry development is critical. In experiments III ~ V, the effects of supplements were examined. The cleavage rates of CZB treatments at 48h were 83.8% in control, 78.1% in BSA+A.A+SIT, 75% in 5% FCS+A. A+SIT, 88.6% in BSA+A.A+SIT and not co-cultured BSA+A.A+SIT had 85.7% and in the case of 240h blastocysts showed 22.6, 0.0, fl.1, 6.5 and 0%, respectively. As a result, this study showed that CZB was effective culture system for in vitro development, and that CZB and CR$_1$aa had no significant differences and effects between them. It may be concluded that in the simple media containing supplements could replace the co-culture systems of bovine early embryo development.

  • PDF

Gentamicin 투여(投與)에 따른 혈중(血中) 및 뇨중(尿中) ${\beta}_2$Microglobuiln 동태(動態)에 관(關)한 연구(硏究) (Changes of the Serum and Urinary $Beta_2$-Microglobulin in the Gentamicin Treated Patients)

  • 김승택;신영태;정순일;최강원;김병국;이정상;이문호
    • 대한핵의학회지
    • /
    • 제14권2호
    • /
    • pp.10-17
    • /
    • 1980
  • Gentamicin is useful to the Gram negative bacterial infection, but its nephrotoxicity is a serious problem and the incidence is probably increasing. The toxicity of gentamicin to the kidney is site-specific to the proximal tubule. In this study, we measured daily peak and trough level of gentamicin, serum creatinine, serum $Beta_2$-microglobulin and 24-hr urine $Beta_2$-microglobulin in 10 gentamicin treated patients. All the patients had their peak levels of gentamicin in the safe therapeutic range, and their trough level showed no evidence of gentamicin accumulation. There was no patient who showed his daily serum creatinine and $Beta_2$-microglobulin rise significantly. But 24-hour urine $Beta_2$-microglobulin showed significant rise from basal level (mean $5.8{\pm}1.62{\times}$) on the 5 th day of gentamicin treatment. Thus, serial monitoring of proximal tubular function with urinary $Beta_2$-microglobulin excretion has potential value in the assessment of insults of gentamicin to this site. But clinical significance of raised urinary $Beta_2$-microglobulin excretion in relation to the serum creatinine should be further studied.

  • PDF

Routine double-J stenting for live related donor kidney transplant recipients: It doesn't serve the purpose, but does it serve a better purpose?

  • Kumar, Vikash;Punatar, Chirag B;Jadhav, Kunal K;Kothari, Jatin;Joshi, Vinod S;Sagade, Sharad N;Kamat, Madhav H
    • Investigative and Clinical Urology
    • /
    • 제59권6호
    • /
    • pp.410-415
    • /
    • 2018
  • Purpose: Despite meticulous techniques, surgical complications continue to be problematic in kidney transplant recipients. Role of routine stenting to reduce complications is controversial. In this study, we compare incidence of early urological complications, lymphoceles, urinary tract infections (UTI) and graft function; with or without double-J stenting. Materials and Methods: All patients who underwent live related donor renal transplantation from February 2014 to February 2016 were included. Transplants prior to February 2015 were without routine stenting; subsequent transplants were with routine stenting. Patients with neurogenic bladder, previously operated bladder and delayed or low urinary output were excluded. Followup was for at least three months. Descriptive statistics was performed for all parameters. Chi square test and Fisher's Exact test were used for qualitative variables. For quantitative variables, Mann-Whitney test was used to test median difference and independent samples t-test for mean difference. The p-value ${\leq}0.05$ was considered significant. Results: We analysed 74 patients (34 stented and 40 non-stented). There was no difference in the incidence of urinary leak, anastomotic obstruction, lymphoceles or UTI (p>0.4 for all comparisons). However, mean estimated glomerular filtration rate at sixth day, 14th day, one month and two months were 76.1 vs. 61.5 (p=0.025), 72.1 vs. 56.6 (p=0.005), 79.4 vs. 63.1 (p=0.002) and 82.0 vs. 63.3 (p=0.001) in the stented versus non-stented groups. Conclusions: Placement of ureteral stent in renal transplant does not significantly affect the incidence of early urinary complications or UTI. However, graft function is significantly better in stented recipients, at least in the short term.

Interaction of Beef Growth Type${\times}$Production System for Carcass Traits of Steers

  • Brown , A.H. Jr.;Camfield, P.K.;Johnson, Z.B.;Rakes, L.Y.;Pohlman, F.W.;Brown, C.J.;Sandelin, B.A.;Baublits, R.T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권2호
    • /
    • pp.259-266
    • /
    • 2005
  • Steers (n=335) of known genetic backgrounds from four fundamentally different growth types were subjected to two production systems to study differences in carcass traits. Growth types were animals with genetic potential for large mature weight-late maturing, intermediate mature weight-late maturing, intermediate mature weight-early maturing and small mature weight-early maturing. Each year, in a nine-year study, calves of each growth type were weaned and five steers of each growth type were developed on pasture or feedlot and slaughtered at approximately 20 and 14 months of age, respectively. Data collected were pre-slaughter shrunk body weight (SBW); hot carcass weight (HCW); dressing percentage (DRESS); fat thickness at the $12^{th}$ and $13^{th}$ rib interface (FAT); percentage kidney, pelvic, and heart fat (KPH); longissimus muscle area (LMA); marbling score (MARB); quality grade (QG); and yield grade (YG). Year and growth type were significant for all carcass traits. The growth type${\times}$production system interaction was an important source of variation in SBW, HCW; FAT, YG and MARB. The same interaction was non-significant for DRESS, KPH, LMA and QG. Carcass differences in measures of fatness were greater in the feedlot system than in the pasture system. These data could aid producers in matching beef growth type to the production system most suitable for efficient use of resources.

Effect of Beef Growth Type on Cooking Loss, Tenderness, and Chemical Composition of Pasture- or Feedlot-developed Steers

  • Brown, A.H.;Camfield, P.K.;Rowe, C.W.;Rakes, L.Y.;Pohlman, F.W.;Johnson, Z.B.;Tabler, G.T.;Sandelin, B.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권11호
    • /
    • pp.1746-1753
    • /
    • 2007
  • Steers (n = 335) of known genetic background from four fundamentally different growth types were subjected to two production systems to study differences in cooking loss (CL), tenderness, and chemical composition. Growth types were animals with genetic potential for large mature weight-late maturing (LL), intermediate mature weight-late maturing (IL), intermediate mature weight -early maturing (IE), and small mature weight-early maturing (SE). Each year, in a nine-year study, calves of each growth type were weaned and five steers of each growth type were developed on pasture or feedlot and harvested at approximately 20 and 14 mo of age, respectively. Data collected were CL and Warner-Bratzler shear force (WBS) for the Longissimus dorsi (LM), Psoas major (PS), and Quadriceps femoris (QF) muscles. Chemical composition was also determined from the right fore- and hindquarter. Data were analyzed using least squares analysis of variance for unequal subclass numbers. The beef growth $type{\times}production$ system interaction was significant for CL and WBS of the LM and ash in the lean trim of the forequarter. Growth types of LL and IL had greater (p<0.05) mean percentage CL in the PS and QF muscles than did IE and SE steers. Growth type LL had the highest (p<0.05) mean for both moisture and protein in the fore- and hindquarters; while SE had the lowest numerical mean value for moisture and protein in the fore- and hindquarters. Shear force of the PS did not differ (p>0.05) among steers of the four growth types. Increasing challenges to the cattle feeding industry may dictate that pasture development play a larger role in future production regimes. Producers should strive to match genetic growth type with available resources in order to remain viable and continue producing a quality product.

Quality of Meat (Longissimus dorsi) from Male Fallow Deer (Dama dama) Packaged and Stored under Vacuum and Modified Atmosphere Conditions

  • Piaskowska, N.;Daszkiewicz, T.;Kubiak, D.;Zapotoczny, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권12호
    • /
    • pp.1782-1789
    • /
    • 2016
  • This study evaluated the effect of vacuum and modified atmosphere (40% $CO_2+60%$ $N_2$, MA) packaging on the chemical composition, physicochemical properties and sensory attributes of chill-stored meat from 10 fallow deer (Dama dama) bucks at 17 to 18 months of age. The animals were hunter-harvested in the forests of north-eastern Poland. During carcass dressing (48 to 54 h post mortem), both musculus longissimus muscles were cut out. Each muscle was divided into seven sections which were allocated to three groups: 0, A, and B. Samples 0 were immediately subjected to laboratory analyses. Samples A were vacuum-packaged, and samples B were packaged in MA. Packaged samples were stored for 7, 14, and 21 days at $2^{\circ}C$. The results of the present study showed that the evaluated packaging systems had no significant effect on the quality of fallow deer meat during chilled storage. However, vacuum-packaged meat samples were characterised by greater drip loss. Vacuum and MA packaging contributed to preserving the desired physicochemical properties and sensory attributes of meat during 21 days of storage. Regardless of the packaging method used, undesirable changes in the colour, water-holding capacity and juiciness of meat, accompanied by tenderness improvement, were observed during chilled storage.

Effects of Dietary Additives and Early Feeding on Performance, Gut Development and Immune Status of Broiler Chickens Challenged with Clostridium perfringens

  • Ao, Z.;Kocher, A.;Choct, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권4호
    • /
    • pp.541-551
    • /
    • 2012
  • The effects of dietary additives and holding time on resistance and resilience of broiler chickens to Clostridium perfringens challenge were investigated by offering four dietary treatments. These were a negative control (basal), a positive control (Zn-bacitracin) and two dietary additives, mannanoligosaccharides (MOS), and acidifier. Two holding times included (a) immediate access to feed and water post hatch (FED) and (b) access to both feed and water 48 h post hatch (HELD). Chicks fed Zn-bacitracin had no intestinal lesions attributed to necrotic enteritis (NE), whereas chicks fed both MOS or acidifier showed signs of NE related lesions. All dietary treatments were effective in reducing the numbers of C. perfringens in the ileum post challenge. The FED chicks had heavier body weight and numerically lower mortality. The FED chicks also showed stronger immune responses to NE challenge, showing enhanced (p<0.05) proliferation of T-cells. Early feeding of the MOS supplemented diet increased (p<0.05) IL-6 production. The relative bursa weight of the FED chicks was heavier at d 21 (p<0.05). All the additives increased the relative spleen weight of the HELD chicks at d 14 (p<0.05). The FED chicks had increased villus height and reduced crypt depth, and hence an increased villus/crypt ratio, especially in the jejunum at d 14 (p<0.05). The same was true for the HELD chicks given dietary additives (p<0.05). It may be concluded that the chicks with early access to dietary additives showed enhanced immune response and gut development, under C. perfringens challenge. The findings of this study shed light on managerial and nutritional strategies that could be used to prevent NE in the broiler industry without the use of in-feed antibiotics.