• Title/Summary/Keyword: B-scan

Search Result 419, Processing Time 0.024 seconds

Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime (어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사)

  • Kim, Jin-Gyum;Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • In the present study, the characteristics of laser ultrasound in the ablation regime are investigated using simulations and experiments. The laser ultrasonic technique has been recognized as a noncontact method in the field of nondestructive tests (NDTs). In hostile environments (such as hot temperatures), this method has various advantages over the conventional contact ultrasonic method. In particular, in the ablation regime, the laser ultrasonic technique is suitable for inspecting internal defects because of the high amplitude and directivity of the longitudinal wave. In this paper, a simulation model for laser ultrasound in the ablation regime was developed. This model was subsequently applied to a defective specimen using the B-scan method to locate defects. Finally, we performed an experimental test to verify the simulation results. Consequently, the simulation demonstrated good agreement with the experimental test.

Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique (Full Matrix Capture 기법을 통한 초음파신호 영상화 향상 연구)

  • Lee, Tae-Hun;Yoon, Byung-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.299-306
    • /
    • 2015
  • A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased array transducer element through all the other elements and captures the complete dataset from every possible transmit-receive combination. This FMC data can be used to create the ultrasonic image in post processing. It is possible to produce not only images equivalent to conventional phased array image but also total focusing method (TFM) images with improved resolution and sharpness, which is virtually focused at any point in a region of interest. In this paper, the system that can perform FMC by using a conventional phased array instrument is developed, and a study was conducted on the imaging algorithms to reconstruct sector B-scan and TFM images from FMC dataset.

Why is Hepatocellular Carcinoma Less Attributable to Viral Hepatitis in Yemen?

  • Saeed, Nadeem Mohammed;Bawazir, Amen Ahmed;Al-Zuraiqi, Masuod;Al-Negri, Fadhel;Yunus, Faisel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3663-3667
    • /
    • 2012
  • The hepatitis B virus (HBV) and the hepatitis C virus (HCV) are still public health problems in Yemen, with older individuals having much higher prevalence than younger generations. However, research on the prevalence of viral hepatitis in association with hepatocellular cancer (HCC) has not yet been undertaken in Yemen. The aim of this study was to determine the prevalence of HBV and HCV infection among HCC patients and to estimate the risk of these infections being associated with the development of HCC. A cross-sectional study was conducted on patients attending oncology outpatient in Sana'a, Yemen, through the period 2008-mid 2010 with confirmed diagnosis of HCC. A total of 88 cases were studied thoroughly with different investigations such as CT-scan, ultrasound, tumour marker, alpha-feto-protein and histopathological biopsy. A structured questionnaire was also applied and physical examination done to assess the general condition of the patients. Statistical package (SPSS version 16) was used for analysis of the data. The mean age of the cases was 61.2 years (${\pm}12.6$) with half over 60 years. There were fewer male patients (36%) compared to females and most (97%) only had basic /no formal education. Seventy nine (89%) were diagnosed as HCC cases with histopathological biopsy while the rest were diagnosed by ultrasound, CT scan, tumour marker, and alpha-feto-protein. Around one-third of the subjects were positive for HBsAg and HCV antibodies. Multivariate analysis showed infection with HCV and use of smoking was associated with HCC diagnosis. Although an association was observed between the occurrence of HCC and viral hepatitis (either HBV or HCV) and cigarette smoking, but the rate of viral infection was lower than what has been reported elsewhere.

Absolute phase identification algorithm in a white light interferometer using a cross-correlation of fringe scans (백색광 간섭기에서 간섭 무늬의 상호 상관관계 함수를 이용한 절대 위상 측정 알고리즘)

  • Kim, Jeong-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.316-326
    • /
    • 2000
  • A new signal processing algorithm for white light interferometry has been proposed and investigated theoretically. The goal of the algorithm is to determine the absolute optical path length of an interferometer with very high precision (<< one optical wavelength). The algorithm features cross-correlation of interferometer fringe scans and hypothesis testing. The hypothesis test looks for a zero order fringe peak candidate about which the cross-correlation is symmetric minimizing the uncertainty of misidentification. The shot noise limited performance of the proposed signal processing algorithm has been analyzed using computer simulations. Simulation results were extrapolated to predict the misidentification rate at Signal to-Shot noise ratio (SNR) higher than 31 dB. Root-mean-square phase error between the computer-generated zero order fringe peak and the estimated zero order fringe peak has been calculated for the changes of three different parameters (SNR, fringe scan sampling rate, coherence length of light source). Results of computer simulations showed the ability of the proposed signal processing algorithm to identify the zero order fringe peak correctly. The proposed signal processing algorithm uses a software approach, which is potentially inexpensive, simple and fast.

  • PDF

A Case of Branchio-Otic Syndrome (아가미귀 증후군 1예)

  • Hong, Jeong-Joo;Shin, Yoo-Seob;Kim, Yun-Tae;Kim, Chul-Ho
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.1
    • /
    • pp.84-87
    • /
    • 2011
  • Branchio-otic syndrome(BOS) is a relatively uncommon genetic malformation associated with dysmorphogenesis of the first and second branchial arches and is characterized by branchial fistulae, congenital preauricular fistulae, and anomalies of the pinnae, external, middle, and inner ears, accompanied by hearing loss. Recently, we experienced a case of BOS in a 10 years old female patient and report this case with a review of literature. 10-year-old girl presented with hearing impairment, bilateral preauricular fistula and cervical fistula. The pure tone audiometry revealed that she had 60dB sensorineural hearing loss on right side and 90dB mixed hearing loss on left. Bilateral branchial fistula was found on the neck CT scan and bilateral ossicular and cochlear abnormality combined with enlarged internal auditory canal was noted on the temporal bone CT scan. To investigate the association with EYA1 gene, we performed DNA sequncing with peripheral white blood cell and found the point mutations on Exon 7, 12 and 16 of EYA1 gene. The preauricular fistula and branchial fistula was excised surgically and hearing aid was applied on her left side. There was no sign of fistula recurrence for seven years after the surgery.

A Study on Abdomen MRI Scan Using Metronome (메트로놈을 이용한 복부 MRI 검사에 대한 연구)

  • Park, Ho-Sung;Kim, Jae-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1138-1143
    • /
    • 2020
  • MRI scans in the abdominal area are difficult to achieve optimal images due to artificial respiration. Among 45 patients (male:female = 30:15) who underwent abdominal MRI examination, a metronome-based examination method was studied for patients whose breathing is difficult and difficult to examine. The images examined without using a metronome were divided into group A, and the images examined using a metronome were divided into group B. Image quality improvement (30%) and inspection time (approximately 50 seconds) were reduced in images using metronome. During abdominal magnetic resonance imaging (ABD MRI), the images examined using a metronome had differences in quality and examination time compared to the unused images. It is more effective to use a metronome brace that controls the patient's respiratory rate during abdominal magnetic resonance imaging under respiratory induction in patients with difficulty in respiratory-gated.

Comparison between FDG Uptake and Clinicopathologic and Immunohistochemical Parameters in Pre-operative PET/CT Scan of Primary Gastric Carcinoma (원발성 위암 환자의 치료 전 PET/CT 스캔에서 FDG 섭취 정도와 임상병리학적 및 면역조직화학적 지표들과의 비교)

  • Han, Eun-Ji;Choi, Woo-Hee;Chung, Yong-An;Kim, Ki-Jun;Maeng, Lee-So;Sohn, Kyung-Myung;Jung, Hyun-Suk;Sohn, Hyung-Sun;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.26-34
    • /
    • 2009
  • Purpose: The purpose of this study was to find out what clinicopathologic or immunohistochemical parameter that may affect FDG uptake of primary tumor in PET/CT scan of the gastric carcinoma patient. Materials and Methods: Eighty-nine patients with stomach cancer who underwent pre-operative FDG PET/CT scans were included. In cases with perceptible FDG uptake in primary tumor, the maximum standardized uptake value (SUVmax) was calculated. The clinicopathologic results such as depth of invasion (T stage), tumor size, lymph node metastasis, tumor differentiation and Lauren's classification and immunohistochemical markers such as Ki-67 index, expression of p53, EGFR, Cathepsin D, c-erb-B2 and COX-2 were reviewed. Results: Nineteen out of 89 gastric carcinomas showed imperceptible FDG uptake on PET/CT images. In cases with perceptible FDG uptake in primary tumor, SUVmax was significantly higher in T2, T3 and T4 tumors than T1 tumors ($5.8{\pm}3.1$ vs. $3.7{\pm}2.1$, p=0.002). SUVmax of large tumors (above or equal to 3 cm) was also significantly higher than SUVmax of small ones (less than 3 cm) ($5.7{\pm}3.2$ vs. $3.7{\pm}2.0$, p=0.002). The intestinal types of gastric carcinomas according to Lauren showed higher FDG uptake compared to the non-intestinal types ($5.4{\pm}2.8$ vs. $3.7{\pm}1.3$, p=0.003). SUVmax between p53 positive group and negative group was significantly different ($6.0{\pm}2.8$ vs. $4.4{\pm}3.0$, p=0.035). No significant difference was found in presence of LN metastasis, tumor differentiation, Ki-67 index, and expression of EGFR, Cathepsin D, c-erb-B2 and COX-2. Conclusion: T stage of gastric carcinoma influenced the detectability of gastric cancer on FDG PET PET/CT scan. When gastric carcinoma was perceptible on PET/CT scan, T stage, size of primary tumor, Lauren's classification and p53 expression were related to degree of FDG uptake in primary tumor.

On the Design Technique and VLSI Structure for a Multiplierless Quincuncial Interpolation Filter (무곱셈 대각 보간 필터의 설계 및 VLSI 구현에 관한 연구)

  • 최진우;이상욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.8
    • /
    • pp.54-65
    • /
    • 1992
  • A huge amount of multiplications is required for 2-D filtering on the image data, making it difficult to implement a real-time quincuncial interpolator. In this paper, efficient design technique and VLSI structures for 2-D multipleierless filter are presented. In the filter design, by introducing an efficient scheme for discretizing the frequency response of the prototype filter, it is shown that a significant amount of the computational burden required in the conventional techniques, such as local search, branch and bound techniques, could be saved. In the case of 5$\times$5 filter, it is found that the design technique described in this paper could save about 80% of the computation time, compared to the conventional methods, while providing a comparable performance. For a hardware implementation, two different VLSI structures for 2-D multiplierless filter are also introduced in the paper : One is for block parallel processing and the other for scan-line parallel processing. In both structure, the AP(area-period) figure improves over Wu's structure[4].

  • PDF

Triangle Method for Fast Face Detection on the Wild

  • Malikovich, Karimov Madjit;Akhmatovich, Tashev Komil;ugli, Islomov Shahboz Zokir;Nizomovich, Mavlonov Obid
    • Journal of Multimedia Information System
    • /
    • v.5 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • There are a lot of problems in the face detection area. One of them is detecting faces by facial features and reducing number of the false negatives and positions. This paper is directed to solve this problem by the proposed triangle method. Also, this paper explans cascades, Haar-like features, AdaBoost, HOG. We propose a scheme using 12-net, 24-net, 48-net to scan images and improve efficiency. Using triangle method for frontal pose, B and B1 methods for other poses in neural networks are proposed.

A study on the sensitivity analysis of processing parameters for the laser surface hardening treatment (레이저 표면 경화처리 긍정변수의 민감도 해석에 관한 연구)

  • 이세환;양영수
    • Proceedings of the KWS Conference
    • /
    • 2000.10a
    • /
    • pp.260-263
    • /
    • 2000
  • A methodology is developed and many used to evaluate the response sensitivity of the thermal systems to variations in their design parameters. Technique for computing the sensitivity of temperature distributions to changes in processing parameters needed for deciding the more effective laser input parameters for laser surface hardening treatment are considered. In this study, a state equation governing the heat flow in laser surface treatment is analyzed using a three-dimensional finite element method and sensitivity data of the processing parameter obtained using a direct differentiation method applied for sensitivity analysis. The interesting processing parameter is taken as the laser scan velocity and characteristic beam radius( $r_{b}$) of the sensitivity of the temperature T versus v and $r_{b}$ is analyzed. And these sensitivity results obtained in another parameters are fixed condition. To verifying the numerical analysis results, hardened layer dimensions (width and depth) of the numerical analysis compared with the results of an experimental data.ata.

  • PDF